INPUT VOLTAGE RECONNECT PROCEDURE

As shipped from the factory, multiple voltage machines are internally configured for the highest input voltage (440-460 VAC), for Code 11366 and (380-415 VAC), for Code 11367.

1.For Connections to 440 or 460 VAC verify the internal configurations to the procedures shown below and refer to Figure A.2.

2.For Connections to 200,208,220,230,380,400 or 415 VAC follow the procedure shown below and refer to figure A.2.

WARNING

NOTE: Turn main power to the machine OFF before performing the reconnect procedure. Failure to do so will result in damage to the machine. DO NOT switch the reconnect bar with machine power ON.

------------------------------------------------------------------------

To Operate at

 

Procedure

 

 

460 or 440 VAC

1. Open reconnect panel

(Code 11366)

 

access door on wraparound.

 

2.

Move input voltage switch

 

 

to Voltage = 380-460V pos-

 

 

ition.

 

3.

Move lead “A” to 440-460

 

 

Terminal.

 

 

 

380 or 415 VAC

1. Open reconnect panel

(Codes 11366)

 

access door on wraparound.

 

2.

Move input voltage switch

 

 

to Voltage = 380-460V

 

 

position.

 

3.

Move lead “A” to 380-415

 

 

Terminal.

 

 

380,400 or 415 VAC

1. Open reconnect panel

(Codes 11367)

 

access door on wraparound.

 

2.

Move input voltage switch

 

 

to Voltage = 380-415V

 

 

position.

 

3.

Move lead “A” to 380-415

 

 

Terminal.

 

 

220 or 230 VAC

1. Open reconnect panel

(Codes 11366)

 

access door on wraparound.

 

2.

Move input voltage switch

 

 

to Voltage = 200 -230V

 

 

position.

 

3.

Move lead “A” to 220-230

 

 

Terminal.

 

 

200 or 208 VAC

1. Open reconnect panel

(Codes 11366)

 

access door on wraparound.

 

2.

Move input voltage switch

 

 

to Voltage = 200 -230V

 

 

position.

 

3.

Move lead “A” to 200-208

 

 

Terminal.

 

 

200 or 208 VAC

1. Open reconnect panel

(Codes 11367)

 

access door on wraparound.

 

2.

Move input voltage switch

 

 

to Voltage = 200 -230V

 

 

position.

 

3.

Move lead “A” to 200-208

 

 

Terminal.

 

 

 

OUTPUT CONNECTIONS

WIRE FEEDER OUTPUT CONNECTIONS

Refer to the Accessories section of this manual for instructions on connecting a wire feeder to the INVERTEC STT II (CE).

The LN-742 or STT-10 wire feeder is the recommended feeder for use with the INVERTEC STT II (CE).

INVERTEC STT II (CE)

Image 12
Contents Safety Depends on You Invertec S T T II CESafety California Proposition 65 WarningsElectric Shock can kill Welding Sparks can cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a L’ArcThank You Table of Contents Installation Technical Specifications -INVERTEC STT II CE For CodeINPUT- Three Phase only Select Suitable Location Input ConnectionsStacking TiltingInput Cable Installation and CON- Nection Ground ConnectionInput Voltage Reconnect Procedure Wire Feeder Output ConnectionsTo Operate at Procedure Output ConnectionsSafety Precautions OperationOperating Instructions General WarningsDesign Features and Advantages Recommended EquipmentWelding Capability Operating ControlsPower Switch Turns output 3B. Peak Current Display Meter ThisWire Feeder Receptacle This is Auxiliary Power Circuit BreakerWelding Parameters and GUIDE- Lines Peak CurrentWelding Procedures for STT Accessories Options / AccessoriesLN-742 or STT-10 Wire Feeder Connection Instructions Figure C.3 STT-10 to STT II Connection Maintenance Input Filter Capacitor Discharge ProcedurePreventive Maintenance Troubleshooting HOW to USE Troubleshooting GuideProblems Symptoms Possible Cause Authorized Field ServiceRecommended Course of Action FacilityProblems Possible Symptoms Cause Troubleshooting Troubleshooting Problems Symptoms Possible Cause Wiring Diagram Invertec STT II CE for Code Wiring Diagram Invertec STT II CE for Code DiagramsDimension Print STT II CE DIAGRAMSF-3Invertec STT II CE Invertec STT II CE Invertec STT II CE Precaucion Warnung