Lincoln Electric IM924 General Description, Recommended Processes and Equipment, Limitations

Page 24

B-4

OPERATION

B-4

 

 

 

GENERAL DESCRIPTION

The Power Wave 455M/STT (CE) semi-automatic power source is designed to be a part of a modular, multi-process welding system. Depending on configura- tion, it can support constant current, constant voltage, STT and pulse welding modes.

The Power Wave 455M/STT (CE) power source is designed to be used with the semi automatic family of Power Feed wire feeders, operating as a system. Each component in the system has special circuitry to "talk with" the other system components, so each compo- nent (power source, wire feeder, user interface) knows what the other is doing at all times. These components communicate with ArcLink

The POWER WAVE 455M/STT (CE) is a high perform- ance, digitally controlled inverter welding power source capable of complex, high-speed waveform control. Properly equipped, it can support the GMAW, GMAW-P, FCAW, SMAW, GTAW, STT and CAC processes. It car- ries an output rating of 400 amps, 36 volts (at 100% duty cycle). The STT process is supported at currents up to 325 amps at 100% duty cycle.

RECOMMENDED PROCESSES AND EQUIPMENT

RECOMMENDED PROCESSES

The POWER WAVE 455M/STT (CE) can be set up in a number of configurations, some requiring optional equipment or welding programs. Each machine is fac- tory preprogrammed with multiple welding procedures, typically including GMAW, GMAW-P, FCAW, SMAW, GTAW, STT and CAC-A for a variety of materials, including mild steel, stainless steel, cored wires, and aluminum.

The POWER WAVE 455M/STT (CE) is recommended for semi-automatic welding with ArcLink compatible equipment like the Power Feed M/STT series of feed- ers. The POWER WAVE 455M/STT (CE) can have a number of modules installed that allow the machine to be used in Robotic and hard automation applications.

Wire Drive Interface Module

For Robotic platforms the Wire Drive Control Module is required to drive the Power Feed-10R wire drive. This module can be factory installed through our automation division or field installed for robotic applications.

The Wire Drive Control Module is also be equipped with a terminal strip for making simple input signal connec- tions. It can be used to externally control the basic wire drive function. It is divided into three groups: Trigger group, Cold Inch group, and Shutdown group.

DeviceNet Interface Module

This module can be used for DeviceNet capability. It will be a 5 pin sealed mini connector per ANSI B93.55M-1981.

EtherNet/DeviceNet Module

This module includes the DeviceNet and EtherNet capability The DeviceNet uses a 5 pin sealed mini connector per ANSI B93.55M-1981. The EtherNet uses a RJ5 connector.

RECOMMENDED EQUIPMENT

Power Wave 455M/STT (CE) – Semi-Automatic Operation

Semi Automatic Power Waves 455M/STT (CE) can only be used with ArcLink compatible Power Feed semi-automatic wire feeders and modules. In addition, the Power Feed semi- automatic wire feeders may require optional equipment to access certain weld modes in the Power Wave. Other mod- els of Lincoln feeders, or any models of non-Lincoln wire feeders, cannot be used.

All welding programs and procedures are selected through the Power Feed M semi-automatic user inter- face

REQUIRED EQUIPMENT

Any ArcLink compatible semi-automatic wire feeding equipment. Specifically, the semi-automatic Power Feed M family.

WARNING

LIMITATIONS

The Power Waves are not to be used in outdoor environments.

------------------------------------------------------------------------

Only ArcLink compatible Power Feed semi-automatic wire feeders and users interfaces may be used. Other Lincoln wire feeders or non-Lincoln wire feeders cannot be used.

POWER WAVE 455M/STT (CE) Output Limitations

The POWER WAVE 455M/STT (CE) will support maximum average output current of 500 Amps (@ 60% duty cycle) on the standard Power Wave stud, and a maximum average output current of 325 amps (100% duty cycle) on the STT stud.

DUTY CYCLE AND TIME PERIOD

The Power Feed wire feeders are capable of welding at 100% duty cycle (continuous welding). The power source will be the limiting factor in determining system duty cycle capability. Note that the duty cycle is based upon a ten minute period. A 60% duty cycle represents 6 minutes of welding and 4 minutes of idling in a ten minute period.

POWER WAVE 455M/STT (CE)

Image 24
Contents Power Wave 455M/STT Safety California Proposition 65 WarningsElectric Shock can kill Welding and Cutting Sparks can Cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a L’ArcSafety Safety Thank You Table of Contents Table of Contents Installation Technical Specifications Power Wave 455M/STT CE K2203-4Machine Grounding High Frequency ProtectionLifting StackingInput Fuse and Supply Wire Considerations Input ConnectionElectrode and Work Cable Connections Table A.1Negative Electrode Polarity Voltage SensingCable INDUCTANCE, and ITS Effects on Pulse Welding System Description Table A.2Work Voltage Sensing Electrode Voltage SensingConfiguring the System Single Head FeederSingle Head Boom Feeder UP to 4 Feeders AllowedDual Head Boom Feeder using two single heads Welding with Multiple Power Waves Control Cable SpecificationsTWO Power Waves Installation Receptacle Specifications DIP Switch Settings and LocationsControl Board DIP Switch Water Flow SensorSafety Precautions OperationPower Wave 455M/STT CE Definition of Welding Terms General Description Recommended Processes and EquipmentRecommended Equipment Required EquipmentPower Wave 455M/STT CE Case Front ControlsCase Front Layout Nominal Procedures Fringe ProceduresWelding Adjustments Making a WeldWelding Mode Constant Voltage WeldingARC Control Pulse Welding Figure A.6 Current Wave Form PulseSTT Welding Figure A.7Accessories Factory InstalledField Installed Optional EquipmentMaintenance Routine MaintenanceTroubleshooting HOW to USE Troubleshooting GuideUsing the Status LED to Troubleshoot System Problems Error Codes for the Powerwave Error Code # Description IndicationAuthorized Field Service Facility Contact your local LincolnIf the Thermal LED is also lit, see Exceeding the 325 amp limit on WFS Power Wave 455M/STT CE Wiring Diagram Connection Diagram Connection Diagram Semi-automatic Simple SystemWire Feeder Work Sense Power Wave 455/STTDiagrams Power Wave 455M/STTPrecaucion Aviso DE