| TROUBLESHOOTING |
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| Observe all Safety Guidelines detailed throughout this manual |
| ||||||||
|
|
|
|
|
|
|
|
|
|
| |
PROBLEMS |
| POSSIBLE AREAS OF |
| RECOMMENDED |
| ||||||
(SYMPTOMS) |
| MISADJUSTMENT(S) |
| COURSE OF ACTION |
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| OUTPUT PROBLEMS |
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
| |
| Machine often “noodle welds” (out- | 1.Secondary current limit has been |
|
|
|
| |||||
| put is limited to approximately 100 |
|
| exceeded, and the machine has |
|
|
|
|
|
| |
| amps) when running a particular |
|
| phased back to protect itself. |
|
|
|
|
|
| |
| procedure, especially a procedure |
|
| 2. Adjust procedure or reduce load |
|
|
|
|
|
| |
| with high WFS. |
|
| to lower current draw from the |
|
|
|
|
|
| |
|
|
|
|
| machine. |
|
|
|
|
|
|
|
|
|
|
| 3. A single phase input (loss of L2) |
|
|
|
|
|
|
|
|
|
|
| will reduce the secondary current |
|
|
|
|
|
|
|
|
|
|
| limit from 570 Amps to 325 |
|
|
|
|
|
|
|
|
|
|
| Amps. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| Machine won’t produce full output. |
|
| 1. Input voltage may be too low, |
|
|
|
|
|
| |
|
|
|
|
| limiting output capability of the |
|
|
|
|
|
|
|
|
|
|
| power source. Make certain that |
|
|
|
|
|
|
|
|
|
|
| the input voltage is proper, |
|
|
|
|
|
|
|
|
|
|
| according to the Rating Plate |
|
|
|
|
|
|
|
|
|
|
| located on the rear of the |
|
|
|
|
|
|
|
|
|
|
| machine. |
|
|
|
|
|
|
|
|
|
|
| 2. Input may be “single phased”. |
|
|
| If all recommended possible areas |
|
|
|
|
|
|
| Make certain the input voltage is |
|
|
|
|
| |
|
|
|
|
|
|
|
| of misadjustments have been |
|
| |
|
|
|
|
| proper on all three Input lines. |
|
|
|
|
| |
|
|
|
|
|
|
|
| checked and the problem persists, |
|
| |
|
|
|
|
| 3. STT machines only: May be |
|
|
|
|
| |
|
|
|
|
|
|
|
| contact your local Lincoln |
|
| |
|
|
|
|
| exceeding the 325 amp limit on |
|
|
|
|
| |
|
|
|
|
|
|
|
| Authorized Field Service Facility. |
|
| |
|
|
|
|
| the STT output terminal. |
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
| 4. Secondary current or voltage not |
|
|
|
|
|
|
|
|
|
|
| be properly calibrated. Check |
|
|
|
|
|
|
|
|
|
|
| values displayed on the Power |
|
|
|
|
|
|
|
|
|
|
| Feed 10/11 verses readings on |
|
|
|
|
|
|
|
|
|
|
| an external meter. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| Auxiliary receptacle is “dead” no |
|
| 1. Circuit breaker CB2 (on case |
|
|
|
|
|
| |
| auxiliary voltage . |
|
| front) may have opened. Reset. |
|
|
|
|
|
| |
|
|
|
|
| 2. Circuit breaker CB4 (in recon- |
|
|
|
|
|
|
|
|
|
|
| nect area) may have opened. |
|
|
|
|
|
|
|
|
|
|
| Reset. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, con- tact your local authorized Lincoln Electric Field Service Facility for technical assistance.