INSTALLATION | ||
|
|
|
Figure 1
CONNECTION OF WELDMARK 225 TO PREMISES WIRING
| 240 VOLT | |
240 Volt | POWER | |
120 VOLT | ||
60 Hz. | ||
COMPANY | ||
120 VOLT | ||
Service | ||
METER | ||
|
GROUNDED CONDUCTOR
NEUTRAL
BUS
N
LOAD
DOUBLE POLE DOUBLE THROW
SWITCH RATING TO BE THE SAME
AS OR GREATER THAN PREMISES
SERVICE OVERCURRENT
PROTECTION.
50 AMP, 120/240
VOLT PLUG240 VOLT NEMA TYPE
40AMP
240VOLT
DOUBLE
POLE
CIRCUIT
BREAKER
GND
N
PREMISES
DISCONNECT AND
SERVICE
GROUNDOVERCURRENT PROTECTION
50 AMP, 120/240 VOLT
RECEPTACLENOTE: No. 6 COPPER CONDUCTOR CABLE SEE NATIONAL ELECTRICAL CODE FOR ALTERNATE WIRE
SIZE RECOMMENDATIONS.
WARNING
Connection of WELDMARK 225 to premises wiring must be done by a licensed electrician and must comply with the National Electrical Code and all other applicable electrical codes.