WELDING PROCESS

For any electrodes the procedures should be kept within the rating of the machine. For electrode infor- mation see the appropriate Lincoln publication.

STICK (CONSTANT CURRENT) WELDING

Connect welding cables to the "TO WORK” and "ELECTRODE” studs. Start the engine. Set the "Polarity” switch to the desired polarity. The “RANGE” switch markings indicate the maximum current for that range as well as the typical electrode size for that range. The “OUTPUT” Control provides fine adjust- ment of the welding current within the select range. For maximum output within a selected range set the “OUTPUT” Control at 10. For minimum output within a selected range set the “OUTPUT” Control at 5. (“OUT- PUT” Control settings below 5 may reduce arc stabili- ty) For best overall welding performance set the “RANGE” Switch to the lowest setting and the OUT- PUT” Control near the maximum to achieve the desired welding current.

RANGE SETTING

TYPICAL

CURRENT RANGE

 

ELECTRODE SIZE

 

90 MAX.

3/32

40 TO 90 AMPS

 

 

 

125 MAX.

1/8

70 TO 145 AMPS

 

 

 

210(DC)/225(AC)

5/32

120 TO 210(DC),

MAX.

 

225(AC) AMPS

 

 

 

The WELDMARK 225 can be used with a broad range of AC and DC stick electrodes. See “Welding Tips 1” included with the WELDMARK 225 for electrodes within the rating of this unit and recommended weld- ing currents of each.

TIG (CONSTANT CURRENT) WELDING

The K930-[ ] TIG Module installed on a Weldmark 225 provides high frequency and shielding gas control for AC and DC GTAW (TIG) welding processes. The TIG Module allows full range output control. After flow time is adjustable from 0 to 55 seconds.

When using the Weldmark 225 for AC TIG welding of aluminum, the following settings and electrodes are recommended:

SETTINGS FOR PURE TUNGSTEN

TUNGSTEN

RANGE SWITCH

APPROXIMATE

DIAMETER (in.)

SETTINGS

CURRENT RANGE

 

 

 

 

 

 

 

 

1/8

90

or

145

80

-

150

Amps

3/32

90

or

145

45

-

130

Amps

1/16

 

90

 

40 - 80 Amps

 

 

 

 

 

 

 

 

SETTINGS FOR  1% THORIATED TUNGSTEN

TUNGSTEN

RANGE SWITCH

APPROXIMATE

DIAMETER (in.)

SETTINGS

CURRENT RANGE

 

 

 

 

 

1/8

90, 145, or 210

80

- 225

Amps

3/32

90 or 145

50

-

180

Amps

1/16

90 or 145

45

-

120

Amps

 

 

 

 

 

 

The K930-[ ] TIG Module should be used with the WELDMARK 225 on high idle to maintain satisfactory operation. It can be used in the AUTO position but the delay going to flow idle after welding is ceased will be increased if the AFTER FLOW CONTROL is set above 10 seconds.

WIRE FEED WELDING PROCESSES (CONSTANT VOLTAGE)

The Innershield® electrode recommended for use with the WELDMARK 225 is NR®-211-MP. The electrode sizes and welding ranges that can be used with the WELDMARK 225 are shown in the following table:

Diameter

Wire Speed

Approximate

(in.)

Range In./Min.

Current Range

 

 

 

 

.035

80

- 110

75A to 120A

.045

70

- 130

120A to 170A

.068

40

- 90

125A to 210A

 

 

 

 

The WELDMARK 225 is recommended for limited “MIG” welding (GMAW - gas metal arc welding). The recommended electrodes are .030” and .035” L-50 and L-56. They must be used with a blended shield- ing gas such as C25 (75% Argon - 25% CO2). The welding ranges that can be used with the WELD- MARK 225 are shown in the following table:

Diameter

Wire Speed

Approximate

(in.)

Range In./Min.

Current Range

 

 

 

.030

80 - 110

75A to 120A

.035

70 - 130

120A to 170A

 

 

 

ARC GOUGING

The Weldmark 225 can be used for limited arc goug- ing.

Set the Range switch to adjust output current to the desired level for the gouging electrode being used according to the ratings in the following table:

ELECTRODE DIAMETER

CURRENT RANGE (DC, electrode positive)

 

 

 

 

1/8

60

-

90 Amps

5/32

90

-

150 Amps

3/16

200 - 250 Amps

 

 

 

 

WELDMARK 225

Image 20
Contents Safety Depends on You WeldmarkSafety WeldmarkElectric Shock can kill Welding and Cutting Sparks can Cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a L’ArcA n k Table of Contents Installation Auxiliary PowerHeight Width Depth Weight Welding OutputSafety Precautions Machine GroundingSpark Arrester TowingPRE-OPERATION Service Battery ConnectionsGasoline Fuel only Vehicle MountingWelding Output Cables Total Combined Length of Electrode and Work CablesAngle of Operation LiftingConnection of Lincoln Electric Wire Feeders Additional Safety PrecautionsInstructions Location / VentilationAuxiliary Power Welder OperationElectrical Device USE with the Weldmark Type Common Electrical Devices Possible ConcernsAuxiliary Power While Welding Simultaneous Welding and PowerStandby Power Connections WELDMARK225Connection of Weldmark 225 to Premises Wiring Engine Switch OperationGENERAL DESCRIPTION Welder Controls Function and OperationPolarity Switch Weldmark 225 Approximate Fuel ConsumptionSTARTING/SHUTDOWN Instructions BREAK-IN PeriodStarting the Engine Stopping the EngineWire Feed Welding Processes Constant Voltage Welding ProcessStick Constant Current Welding TIG Constant Current WeldingStick Auto Accessories Optional Equipment Field Installed2ACCESSORIESC-2 WIRE FEEDRECOMMENDED EQUIPMENT StickMaintenance Safety PrecautionsRoutine Maintenance Engine OIL ChangeAIR Cleaner and Other Maintenance OIL Filter ChangeEngine Adjustments Overspeed is Hazardous BatteryEngine Maintenance Parts Slip RingsTroubleshooting HOW to USE Troubleshooting GuideTroubleshooting Troubleshooting Wiring Diagrams Diagrams Warni NGDimension Print Weldmark 225 KohlerPrecaucion Warnung Weldmark