Lincoln Electric IM823-A manual GUN and Cable Assemblies, Electrode Polarity, Connections, Pin

Page 14

A-5

INSTALLATION

A-5

 

 

 

GUN AND CABLE ASSEMBLIES

A variety of Lincoln 10' (3.0m) or 15' (4.6m) gun and cable assemblies are available for use with the LN™- 15, including the Magnum™ models for GMAW, K126 or K115 models for Innershield®.

The LN™-15 comes factory equipped with a K1500-2 gun connection kit, designed for guns having a Magnum Tweco™ compatible #2-#4 connector. Many other guns can easily be used with the LN™-15 with other K1500 series gun connection kits.

Gun Cable Connection to the Feeder

Lay the cable out straight. Insert the connector on the welding conductor cable into the brass bushing on the front of the wire drive unit. Keep the all mating sur- faces clean. Make sure it is fully seated and tighten the thumb screw.

Connect the control cable plug into the 5 pin recepta- cle on the front panel of the wire feeder.

ELECTRODE POLARITY

The LN™-15 automatically adjusts for positive and negative polarity. When welding with negative polarity procedures, the voltmeter will display a "-" sign; exam- ple "-23.6" Volts.

PROCEDURE TO INSTALL DRIVE ROLLS AND WIRE GUIDES

WARNING

Turn off input power at the weld- ing power source before installa- tion or changing drive roll and/or wire guides.

Do not touch electrically live parts such as the wire drive or internal wiring.

When feeding with the gun trigger, the electrode and wire drive mechanism are "hot" to work and ground and could remain energized several sec- onds after the gun trigger is released.

Only qualified personnel should perform this operation.

-------------------------------------------------------------------

1.Turn OFF the welding power source.

2.Open the LN™-15 case and then release the idle roll pressure arm.

3.Remove the outer wire guide by turning the knurled thumbscrews counter-clockwise to unscrew them from the feed plate.

4.Rotate the triangular shaped drive roll retaining mechanism to unlock the drive rolls and remove the drive rolls.

CONNECTIONS

Across the Arc LN™-15 models do not use a control cable.

Table A.2 Trigger Connector J1 (5 Pin)

PIN

Lead #

Function

A

556

Trigger

B

-

Not used

C

554

Trigger/ 83%

 

 

Procedure ground

D

555

83% Procedure

E

554

Trigger/ 83%

 

 

Procedure ground

5.Remove the inner wire guide.

6.Insert the new inner wire guide, groove side out, over the two locating pins in the feed plate.

7.Install a drive roll on each hub assembly and lock by rotating the triangular drive roll retaining mecha- nism.

8.Install the outer wire guide by aligning it with the pins and tightening the knurled thumbscrews.

9.Close the idle arm and engage the idle roll pressure arm. Adjust the pressure appropriately.

LN™-15 ACROSS THE ARC MODEL & (CE)

Image 14
Contents LN -15 Wire Feeder Safety California Proposition 65 WarningsElectric Shock can kill Welding and Cutting Sparks can Cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a L’ArcSafety Safety Thank You Table of Contents LN-15 Across the ARC Model & CE InstallationTechnical Specifications LN-15 K1870-1, K1870-2 CE Work Clip Lead Safety PrecautionsLocation High Frequency ProtectionWeld Cable Connections Engine Drive Power Source ConnectionPower Source Connection Electrode ConnectionFigure A.1 Electrode Polarity Procedure to Install Drive Rolls and Wire GuidesGUN and Cable Assemblies ConnectionsFeeding Wire Electrode Safety Precautions OperationGeneral Description 83% Procedure Across the ARC ModelWelding Mode CV/CC Mode and WFS Units LN-15 POWER-UP SequenceNormal POWER-UP Display PREFLOW, Postflow and Burnback TimesWFS Units CV/CC ModeSpring Tension ARM Set the pressure arm as follows See Figure B.2aWire Drive Configuration Cold FEED/GAS Purge SwitchSpindle Brake Step Trigger Interlock SwitchFlow Meter Shielding GAS ConnectionConstant Current Operation Figure B.3Figure B.4 CC Wire Speed Setting Making a Weld Optional Equipment AccessoriesFactory Installed Equipment Periodic Maintenance MaintenanceRoutine Maintenance Calibration SpecificationTroubleshooting HOW to USE Troubleshooting GuideAuthorized Field Service Facility ProblemsRecommended Symptoms Course of ActionField Service Facility Your local Lincoln AuthorizedErrors on the Display Fault Code Description Possible AdjustmentsDiagrams LN-15 Across the ARC ModelDiagrams Dimension Print G4053-5LN-15 Across the ARC Model & CE LN-15 Across the ARC Model & CE LN-15 Across the ARC Model & CE Precaucion Warnung