MAINTENANCE

D-1

 

 

 

SAFETY PRECAUTIONS

WARNING

ELECTRIC SHOCK can kill.

• Do not operate with covers removed.

Turn off power source before installing or servicing.

Do not touch electrically hot parts.

Turn the input power to the welding power source off at the fuse box before working in the terminal strip.

Only qualified personnel should install, use or service this equipment.

ROUTINE MAINTENANCE

Routine maintenance consists of periodically blowing out the machine, using a low pressure airstream, to remove accumulated dust and dirt from inside the feeder.

PERIODIC MAINTENANCE

Replace the drive rolls and inner wire guide when they are worn.

Replace the pig tail if the insulation is cut, abraded or damaged.

CALIBRATION SPECIFICATION

All calibration is factory set on the LN™-15.

To verify the wire feed speed:

Assemble a .045 (1.2mm) drive roll kit into the LN™-15.

Load a spool of .045 (1.2mm) electrode and thread the electrode through the wire drive.

Adjust the wire feed speed to 300 in/min (7.62m/min).

Press the COLD FEED switch and measure the actual wire feed speed with a calibrated wire feed speed tachometer.

The measured wire feed speed should be within 2% of the set value.

To verify the voltage display:

Set the welding power source and LN™-15 to a CV procedure that gives steady "spray" transfer in the arc.

While a weld is being made, measure the voltage from the feed plate to work.

The displayed voltage on the LN™-15 should be within 2% of the measured value.

LN™-15 ACROSS THE ARC MODEL & (CE)

Image 27
Contents LN -15 Wire Feeder California Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding and Cutting Sparks can Cause fire or explosionSûreté Pour Soudage a L’Arc Précautions DE SûretéSafety Safety Thank You Table of Contents Installation Technical Specifications LN-15 K1870-1, K1870-2 CELN-15 Across the ARC Model & CE High Frequency Protection Safety PrecautionsLocation Work Clip LeadElectrode Connection Engine Drive Power Source ConnectionPower Source Connection Weld Cable ConnectionsFigure A.1 Connections Procedure to Install Drive Rolls and Wire GuidesGUN and Cable Assemblies Electrode PolarityFeeding Wire Electrode Operation Safety PrecautionsGeneral Description Across the ARC Model 83% ProcedurePREFLOW, Postflow and Burnback Times LN-15 POWER-UP SequenceNormal POWER-UP Display Welding Mode CV/CC Mode and WFS UnitsSet the pressure arm as follows See Figure B.2a CV/CC ModeSpring Tension ARM WFS UnitsCold FEED/GAS Purge Switch Wire Drive ConfigurationShielding GAS Connection Step Trigger Interlock SwitchFlow Meter Spindle BrakeFigure B.3 Constant Current OperationFigure B.4 CC Wire Speed Setting Making a Weld Accessories Factory Installed EquipmentOptional Equipment Calibration Specification MaintenanceRoutine Maintenance Periodic MaintenanceHOW to USE Troubleshooting Guide TroubleshootingCourse of Action ProblemsRecommended Symptoms Authorized Field Service FacilityYour local Lincoln Authorized Field Service FacilityFault Code Description Possible Adjustments Errors on the DisplayLN-15 Across the ARC Model DiagramsDiagrams G4053-5 Dimension PrintLN-15 Across the ARC Model & CE LN-15 Across the ARC Model & CE LN-15 Across the ARC Model & CE Precaucion Warnung