TROUBLESHOOTING

E-3

 

 

 

 

Observe all Safety Guidelines detailed throughout this manual

 

 

 

 

PROBLEMS

(SYMPTOMS)

POSSIBLE

CAUSE

RECOMMENDED

COURSE OF ACTION

The Wire Feed Speed Range is only

1. The 83% wire feed speed dual

 

50 - 374 in/min ( 1.3 - 9.5 m/min)

 

procedure is activated with the low

 

 

 

speed gear. Check dual procedure

 

 

 

switch in gun.

 

 

 

 

 

 

 

DISPLAY PROBLEMS

 

"POS", "PRE" or "BRN" show on the

1.

The LN™-15 is in the Press and

 

display.

 

Spin set-up mode.

 

 

2.

One of the DIP switches on the

 

 

 

feed head board is set to "ON" for

 

 

 

timer setting mode.

 

 

3. Cycle power to the LN™-15 or

 

 

 

wait 45 seconds.

If all recommended possible areas of

 

4.

The LN™-15 is an old ALPHA unit

misadjustment have been checked

 

 

and a DIPswitch is in the wrong

and the problem persists, Contact

 

 

position.

your local Lincoln Authorized

 

 

 

Field Service Facility.

The voltage display reads "0.0" volts

1.

The power source meter polarity

during welding

 

switch is in the wrong position.

 

 

2.

Set the power source meter polar-

 

 

 

ity switch to match the welding

 

 

 

process.

 

 

 

 

 

 

 

WELDING PROBLEMS

 

Porosity in the weld.

1.

The part being welded is wet, dirty

 

Variable or "hunting" arc.

 

or rusty.

 

 

2.

The electrode being used is wet,

 

 

 

dirty or rusty.

 

 

3.

There is insufficient shielding gas

 

 

 

flow from possible cuts in the gas

 

 

 

hose

 

 

4.

There is moisture or water in the

 

 

 

shielding gas line.

 

 

5.

There is too much shielding gas

 

 

6.

There is too much wind or drafts.

If all recommended possible areas of

 

7.

The arc voltage is set too high.

 

misadjustment have been checked

 

8.

The wrong shielding gas is being

 

 

used.

and the problem persists, Contact

 

 

your local Lincoln Authorized

Variable or "hunting" arc.

1.

Worn and/or melted contact tip.

 

2. Worn work cable or poor work

Field Service Facility.

 

 

connection.

 

 

3.

Loose electrode connection.

 

 

4.

Wrong electrode polarity for the

 

 

 

process being used.

 

 

 

 

 

The arc burns back to the tip.

1.

The spool of electrode is tangled.

 

 

2.

The electrode and work leads are reversed

 

 

 

(welding with the wrong polarity.)

 

 

3.

The liner is clogged.

 

 

4.

The contact tip is worn.

 

 

5.

The wire drive tension is improp-

 

 

 

erly set.

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

LN™-15 ACROSS THE ARC MODEL & (CE)

Image 30
Contents LN -15 Wire Feeder Safety California Proposition 65 WarningsElectric Shock can kill Welding and Cutting Sparks can Cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a L’ArcSafety Safety Thank You Table of Contents Installation Technical Specifications LN-15 K1870-1, K1870-2 CELN-15 Across the ARC Model & CE Work Clip Lead Safety PrecautionsLocation High Frequency ProtectionWeld Cable Connections Engine Drive Power Source ConnectionPower Source Connection Electrode ConnectionFigure A.1 Electrode Polarity Procedure to Install Drive Rolls and Wire GuidesGUN and Cable Assemblies ConnectionsFeeding Wire Electrode Safety Precautions OperationGeneral Description 83% Procedure Across the ARC ModelWelding Mode CV/CC Mode and WFS Units LN-15 POWER-UP SequenceNormal POWER-UP Display PREFLOW, Postflow and Burnback TimesWFS Units CV/CC ModeSpring Tension ARM Set the pressure arm as follows See Figure B.2aWire Drive Configuration Cold FEED/GAS Purge SwitchSpindle Brake Step Trigger Interlock SwitchFlow Meter Shielding GAS ConnectionConstant Current Operation Figure B.3Figure B.4 CC Wire Speed Setting Making a Weld Accessories Factory Installed EquipmentOptional Equipment Periodic Maintenance MaintenanceRoutine Maintenance Calibration SpecificationTroubleshooting HOW to USE Troubleshooting GuideAuthorized Field Service Facility ProblemsRecommended Symptoms Course of ActionField Service Facility Your local Lincoln AuthorizedErrors on the Display Fault Code Description Possible AdjustmentsDiagrams LN-15 Across the ARC ModelDiagrams Dimension Print G4053-5LN-15 Across the ARC Model & CE LN-15 Across the ARC Model & CE LN-15 Across the ARC Model & CE Precaucion Warnung