Lincoln Electric IM823-A manual Wire Drive Configuration, Cold FEED/GAS Purge Switch

Page 21

B-6

OPERATION

B-6

 

 

 

WIRE DRIVE CONFIGURATION

(See Figure B..2b)

Changing the Gun Receiver Bushing

ELECTRIC SHOCK can kill.

Turn the input power OFF at the welding power source before installation or changing drive rolls and/or guides.

Do not touch electrically live parts.

When inching with the gun trigger, electrode and drive mechanism are "hot" to work and ground and could remain energized several seconds after the gun trigger is released.

Only qualified personnel should perform mainte- nance work.

-----------------------------------------------------------------

Tools required:

• 1/4" hex key wrench.

Note: Some gun bushings do not require the use of the thumb screw.

1.Turn power off at the welding power source.

2.Remove the welding wire from the wire drive.

3.Remove the thumb screw from the wire drive.

4.Remove the welding gun from the wire drive.

5.Loosen the socket head cap screw that holds the connector bar against the gun bushing.

Important: Do not attempt to completely remove the socket head cap screw.

6.Remove the outer wire guide, and push the gun bushing out of the wire drive. Because of the pre- cision fit, light tapping may be required to remove the gun bushing.

7.Disconnect the shielding gas hose from the gun bushing, if required.

8.Connect the shielding gas hose to the new gun bushing, if required.

9.Rotate the gun bushing until the thumb screw hole aligns with the thumb screw hole in the feed plate. Slide the gun receiver bushing into the wire drive and verify the thumb screw holes are aligned.

10.Tighten the socket head cap screw.

11.Insert the welding gun into the gun bushing and tighten the thumb screw.

COLD FEED/GAS PURGE SWITCH

Cold Feed and Gas Purge are combined into a single spring centered toggle switch.

To activate Cold Feeding, hold the switch in the UP position. The wire drive will feed electrode but neither the power source nor the gas solenoid will be energized. Adjust the speed of cold feeding by rotat- ing the WFS knob. Cold feeding, or "cold inching" the electrode is useful for thread- ing the electrode through the gun.

FIGURE B.2b

THUMB SCREW

GUN RECEIVER BUSHING

OUTER WIRE GUIDE

CONNECTOR BLOCK

SOCKET HEAD

CAP SCREW

LOOSEN TIGHTEN

LN™-15 ACROSS THE ARC MODEL & (CE)

Image 21
Contents LN -15 Wire Feeder California Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding and Cutting Sparks can Cause fire or explosionSûreté Pour Soudage a L’Arc Précautions DE SûretéSafety Safety Thank You Table of Contents Installation Technical Specifications LN-15 K1870-1, K1870-2 CELN-15 Across the ARC Model & CE Location Safety PrecautionsWork Clip Lead High Frequency ProtectionPower Source Connection Engine Drive Power Source ConnectionWeld Cable Connections Electrode ConnectionFigure A.1 GUN and Cable Assemblies Procedure to Install Drive Rolls and Wire GuidesElectrode Polarity ConnectionsFeeding Wire Electrode Operation Safety PrecautionsGeneral Description Across the ARC Model 83% ProcedureNormal POWER-UP Display LN-15 POWER-UP SequenceWelding Mode CV/CC Mode and WFS Units PREFLOW, Postflow and Burnback TimesSpring Tension ARM CV/CC ModeWFS Units Set the pressure arm as follows See Figure B.2aCold FEED/GAS Purge Switch Wire Drive ConfigurationFlow Meter Step Trigger Interlock SwitchSpindle Brake Shielding GAS ConnectionFigure B.3 Constant Current OperationFigure B.4 CC Wire Speed Setting Making a Weld Accessories Factory Installed EquipmentOptional Equipment Routine Maintenance MaintenancePeriodic Maintenance Calibration SpecificationHOW to USE Troubleshooting Guide TroubleshootingRecommended Symptoms ProblemsAuthorized Field Service Facility Course of ActionYour local Lincoln Authorized Field Service FacilityFault Code Description Possible Adjustments Errors on the DisplayLN-15 Across the ARC Model DiagramsDiagrams G4053-5 Dimension PrintLN-15 Across the ARC Model & CE LN-15 Across the ARC Model & CE LN-15 Across the ARC Model & CE Precaucion Warnung