Lincoln Electric IM823-A manual LN-15 POWER-UP Sequence, Normal POWER-UP Display

Page 19

B-4

OPERATION

B-4

 

 

 

LN™-15 POWER-UP SEQUENCE

NORMAL POWER-UP DISPLAY

When power is first applied to the LN™-15, the dis- play will momentarily show set-up information. For example, it may show "CV" and "HI", indicating oper- ation from a CV power source and the wire drive is configured for the high speed gear. Because of limita- tions in the display, "CV" will appear as "Cu".

After a brief moment, the LN™-15 will then display the WFS and "---". No voltage is displayed until the trigger is pressed.

Preflow:

Postflow:

Burnback:

3.Activate and then release the GAS PURGE switch to select the timer. The time will then display in the right hand side of the display. Example:

4.Rotate the WFS knob to adjust the time to the new setting.

WFS

PREFLOW, POSTFLOW AND BURNBACK TIMES

Preflow, Postflow and Burnback times are all adjustable on the LN™-15. The LN™-15 is factory set with all the times set to 0.0 seconds.

The burnback time is adjustable from 0.00 to 0.25 seconds.

The preflow time is adjustable from 0.0 to 25.0 sec- onds.

The postflow time is adjustable from 0.0 to 25.0 sec- onds.

CHANGING PREFLOW, POSTFLOW OR BURNBACK TIMES:

1.Enter the “Press Spin” Set-Up Mode:

While the power to the LN™-15 is off, activate and hold the GAS PURGE switch (Down Position). Turn on power to the LN™-15, and continue to hold the GAS PURGE switch until the LN™-15 dis- plays "Press Spin". Release the GAS PURGE

COLD

FEED

GAS PURGE

switch. The LN™-15 is now in the "Press Spin" set- up mode. If after 15 seconds no other action is taken, the LN™-15 will then revert to normal oper- ation.

2.Rotate the WFS knob until the desired timer is dis- played.

5.Press the GAS PURGE switch again to save the setting. The LN™-15 will then return to the original "Press Spin" mode in step 1.

6.To exit the "Press Spin" set-up mode, turn off power to the LN™-15, or simply wait 15 seconds and the LN™-15 will enter normal operation.

WELDING MODE CV/CC MODE AND WFS UNITS

The CV/CC mode and WFS units are all readily changed during the power-up sequence. The LN™-15 is factory set for "CV" welding power sources and "inches per minute" for the wire feed speed units.

The CV/CC mode is selectable for either CV for Constant Voltage power sources and CC for Constant Current power sources. Use CV power sources when making critical welds.

The WFS units is selectable for either in/min and m/min.

CHANGING THE CV/CC MODE, OR WFS UNITS:

1.Enter the “Press Spin” Set-Up Mode:

While the power to the LN™-15 is off, activate and hold the GAS PURGE switch (Down Position). Turn on power to the LN™-15, and continue to hold the GAS PURGE switch until the LN™-15 displays "Press spin". Release the GAS PURGE switch.

COLD

FEED

GAS PURGE

The LN™-15 is now in the "Press Spin" set-up mode. If after 15 seconds no other action is taken, the LN™-15 will then revert to normal operation.

LN™-15 ACROSS THE ARC MODEL & (CE)

Image 19
Contents LN -15 Wire Feeder California Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding and Cutting Sparks can Cause fire or explosionSûreté Pour Soudage a L’Arc Précautions DE SûretéSafety Safety Thank You Table of Contents Technical Specifications LN-15 K1870-1, K1870-2 CE InstallationLN-15 Across the ARC Model & CE High Frequency Protection Safety PrecautionsLocation Work Clip LeadElectrode Connection Engine Drive Power Source ConnectionPower Source Connection Weld Cable ConnectionsFigure A.1 Connections Procedure to Install Drive Rolls and Wire GuidesGUN and Cable Assemblies Electrode PolarityFeeding Wire Electrode Operation Safety PrecautionsGeneral Description Across the ARC Model 83% ProcedurePREFLOW, Postflow and Burnback Times LN-15 POWER-UP SequenceNormal POWER-UP Display Welding Mode CV/CC Mode and WFS UnitsSet the pressure arm as follows See Figure B.2a CV/CC ModeSpring Tension ARM WFS UnitsCold FEED/GAS Purge Switch Wire Drive ConfigurationShielding GAS Connection Step Trigger Interlock SwitchFlow Meter Spindle BrakeFigure B.3 Constant Current OperationFigure B.4 CC Wire Speed Setting Making a Weld Factory Installed Equipment AccessoriesOptional Equipment Calibration Specification MaintenanceRoutine Maintenance Periodic MaintenanceHOW to USE Troubleshooting Guide TroubleshootingCourse of Action ProblemsRecommended Symptoms Authorized Field Service FacilityYour local Lincoln Authorized Field Service FacilityFault Code Description Possible Adjustments Errors on the DisplayLN-15 Across the ARC Model DiagramsDiagrams G4053-5 Dimension PrintLN-15 Across the ARC Model & CE LN-15 Across the ARC Model & CE LN-15 Across the ARC Model & CE Precaucion Warnung