Lincoln Electric IM808-A manual System Description, Table A.2, Work Voltage Sensing

Page 15

A-5

INSTALLATION

A-5

 

 

 

Enable the voltage sense leads as follows:

TABLE A.2

Process

Electrode Voltage

Work Voltage

 

Sensing 67 lead *

Sensing 21 lead

 

 

 

 

GMAW

67 lead required

21 lead optional

GMAW-P

67 lead required

21 lead optional

FCAW

67 lead required

21 lead optional

STT

67 lead required

21 lead required

GTAW

Voltage sense at studs

Voltage sense at studs

GMAW

Voltage sense at studs

Voltage sense at studs

SAW

67 lead required

21 lead optional

CAC

Voltage sense at studs

Voltage sense at studs

*The electrode voltage 67 sense lead is integral to the control cable to the wire feeder.

Work Voltage Sensing

The standard Power Wave 455M/STT (CE) is shipped with the work voltage sense lead enabled.

For processes requiring work voltage sensing, connect the (21) work voltage sense lead (K940) from the Power Wave work sense lead receptacle to the work piece. Attach the sense lead to the work piece as close to the weld as practical, but not in the return current path. Enable the work voltage sensing in the Power Wave as follows:

1.Turn off power to the power source at the disconnect switch.

2.Remove the front cover from the power source.

3. The control board is on the left side of the

 

 

 

 

 

 

 

 

7 8

 

 

 

power source. Locate the 8-position DIP

 

 

 

 

 

switch and look for switch 8 of the DIP

 

 

6

 

 

 

switch.

 

 

5

 

 

 

 

 

 

4

 

 

 

4. Using a pencil or other small object, slide

 

 

3

 

 

 

 

 

1 2

 

 

 

the switch right to the OFF position if the

 

 

 

 

 

work sense lead is NOT connected.

 

 

 

 

 

 

 

 

 

 

 

 

O N

 

 

 

 

 

Conversely, slide the switch to the ON position if the work sense lead is present.

5.Replace the cover and screws. The PC board will “read” the switch at power up, and configure the work voltage sense lead appropriately.

Electrode Voltage Sensing

Enabling or disabling electrode voltage sensing is automatically configured through software. The 67 electrode sense lead is internal to the cable to the wire feeder and always connected when a wire feeder is present.

CAUTION

Important: The electrode polarity must be config- ured at the feed head for all semi-automatic processes. Failure to do so may result in extreme- ly high welding outputs.

------------------------------------------------------------------------

POWER WAVE TO SEMI-AUTOMAT- IC POWER FEED WIRE FEEDER INTERCONNECTIONS

The Power Wave 455M/STT (CE) and semi-automatic POWER FEED family communicate via a 5 conductor control cable (K1543). The control cable consists of two power leads, one twisted pair for digital communication, and one lead for voltage sensing. The cables are designed to be connected end to end for ease of exten- sion. The output receptacle on the Power Wave 455M/STT (CE) is located beneath the spring loaded out- put cover at the bottom of the case front. The input recep- tacle on the Power Feed is typically located at the back of the feeder, or on the bottom of the user interface.

For convenience sake, the electrode and control cables can be routed behind the left or right strain reliefs (under the spring loaded output cover), and along the channels formed into the base of the Power Wave, out the back of the channels, and then to the wire feeder.

Due to the flexibility of the platform the configuration may vary. The following is a general description of the system. For specific configuration information, consult the semi- automatic Power Feed instruction manual.

SYSTEM DESCRIPTION

The Power Wave 455M/STT (CE) and Power Feed M family of products utilize a digital communication system called ArcLink. Simply put, ArcLink allows large amounts of information to be passed at very high speeds between components (nodes) in the system. The system requires only two wires for communication, and because of its bus- like structure, the components may be connected to the network in any order, thus simplifying the system set-up.

Each "system" must contain only one power source. The number of wire feeders is determined by the type of wire feeder. Refer to the wire feeder instruction man- ual for details

POWER WAVE 455M/STT (CE)

Image 15
Contents Power Wave 455M/STT California Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding Sparks can cause fire or explosionSûreté Pour Soudage a L’Arc Précautions DE SûretéSafety Safety Thank You Table of Contents Table of Contents Technical Specifications Power Wave 455M/STT CE K2203-2 InstallationStacking Machine GroundingHigh Frequency Protection LiftingTable A.1 Input Fuse and Supply Wire ConsiderationsInput Connection Electrode and Work Cable ConnectionsNegative Electrode Polarity Voltage SensingCable INDUCTANCE, and ITS Effects on Pulse Welding Electrode Voltage Sensing System DescriptionTable A.2 Work Voltage SensingUP to 4 Feeders Allowed Configuring the SystemSingle Head Feeder Single Head Boom FeederDual Head Boom Feeder using two single heads Control Cable Specifications Welding with Multiple Power WavesInstallation Water Flow Sensor Receptacle SpecificationsDIP Switch Settings and Locations Control Board DIP SwitchOperation Safety PrecautionsPower Wave 455M/STT CE Definition of Welding Terms Required Equipment General DescriptionRecommended Processes and Equipment Recommended EquipmentPower Wave 455M/STT CE Case Front ControlsCase Front Layout Making a Weld Nominal ProceduresFringe Procedures Welding AdjustmentsWelding Mode Constant Voltage WeldingARC Control Figure A.6 Current Wave Form Pulse Pulse WeldingFigure A.7 STT WeldingOptional Equipment AccessoriesFactory Installed Field InstalledRoutine Maintenance MaintenanceHOW to USE Troubleshooting Guide TroubleshootingUsing the Status LED to Troubleshoot System Problems Error Code # Description Indication Error Codes for the PowerwaveContact your local Lincoln Authorized Field Service FacilityIf the Thermal LED is also lit, see Exceeding the 325 amp limit on STT output terminal WFS 455M/STT Power Wave 455M/STT CE Wiring DiagramConnection Diagram Semi-automatic Simple System Connection DiagramPower Wave 455/STT Wire Feeder Work SenseDimension Print Power Wave 455M DiagramsPage Precaucion Aviso DE