Lincoln Electric IM808-A manual If the Thermal LED is also lit, see

Page 36

E-5

 

TROUBLESHOOTING

E-5

 

 

 

 

 

 

 

 

 

 

Observe all Safety Guidelines detailed throughout this manual

 

 

 

 

 

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

 

(SYMPTOMS)

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

 

 

OUTPUT PROBLEMS

 

 

Thermal LED is lit.

1. Fan

thermostat

has opened.

 

 

 

 

Check for proper fan operation.

 

 

 

 

(Fan should run whenever output

 

 

 

 

power is on.) Check for material

 

 

 

 

blocking intake or exhaust lou-

 

 

 

 

vers, or for excessive dirt clog-

 

 

 

 

ging

cooling

channels in

 

 

 

 

machine.

 

 

 

2.Secondary rectifier or Choke thermostat has opened. After machine has cooled, reduce load, duty cycle, or both. Check for material blocking intake or exhaust louvers.

3.DC Bus PC board thermostat has opened check for excessive load on 40VDC supply.

Machine wont weld, cant get any

1. Input

voltage

is

too

low or too

If all recommended possible areas

output. (CR1 will not pull in.)

high. Make certain that input volt-

 

age is proper, according to the

of misadjustments have been

 

Rating Plate located on the rear

checked and the problem persists,

 

of the machine.

 

 

 

contact your local Lincoln

 

2. If the Thermal LED is also lit, see

Authorized Field Service Facility.

 

Yellow Thermal LED is Litsec-

 

 

tion.

 

 

 

 

 

 

 

3. Primary current limit has been

 

 

exceeded. Possible short in out-

 

 

put circuit. Turn machine off.

 

 

Remove all loads from the output

 

 

of the machine. Turn back on. If

 

 

condition persists, turn power off,

 

 

and

contact

an

authorized

 

 

Lincoln Electric

Field

Service

 

 

facility.

 

 

 

 

 

 

4. This problem will normally be

 

 

accompanied by an error code.

 

 

Error codes are displayed as a

 

 

series of red and green flashes by

 

 

the

status

 

light.

See

 

 

"Troubleshooting the Power Wave

 

/Power Feed System Using the Status LED" section of this text.

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, con- tact your local authorized Lincoln Electric Field Service Facility for technical assistance.

POWER WAVE 455M/STT (CE)

Image 36
Contents Power Wave 455M/STT Safety California Proposition 65 WarningsElectric Shock can kill Welding Sparks can cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a L’ArcSafety Safety Thank You Table of Contents Table of Contents Installation Technical Specifications Power Wave 455M/STT CE K2203-2Machine Grounding High Frequency ProtectionLifting StackingInput Fuse and Supply Wire Considerations Input ConnectionElectrode and Work Cable Connections Table A.1Negative Electrode Polarity Voltage SensingCable INDUCTANCE, and ITS Effects on Pulse Welding System Description Table A.2Work Voltage Sensing Electrode Voltage SensingConfiguring the System Single Head FeederSingle Head Boom Feeder UP to 4 Feeders AllowedDual Head Boom Feeder using two single heads Welding with Multiple Power Waves Control Cable SpecificationsInstallation Receptacle Specifications DIP Switch Settings and LocationsControl Board DIP Switch Water Flow SensorSafety Precautions OperationPower Wave 455M/STT CE Definition of Welding Terms General Description Recommended Processes and EquipmentRecommended Equipment Required EquipmentPower Wave 455M/STT CE Case Front ControlsCase Front Layout Nominal Procedures Fringe ProceduresWelding Adjustments Making a WeldWelding Mode Constant Voltage WeldingARC Control Pulse Welding Figure A.6 Current Wave Form PulseSTT Welding Figure A.7Accessories Factory InstalledField Installed Optional EquipmentMaintenance Routine MaintenanceTroubleshooting HOW to USE Troubleshooting GuideUsing the Status LED to Troubleshoot System Problems Error Codes for the Powerwave Error Code # Description IndicationAuthorized Field Service Facility Contact your local LincolnIf the Thermal LED is also lit, see Exceeding the 325 amp limit on STT output terminal WFS Power Wave 455M/STT CE Wiring Diagram 455M/STTConnection Diagram Connection Diagram Semi-automatic Simple SystemWire Feeder Work Sense Power Wave 455/STTDiagrams Dimension Print Power Wave 455MPage Precaucion Aviso DE