Lincoln Electric IM931 manual Welder / Generator Maintenance

Page 30

D-5

MAINTENANCE

D-5

 

 

 

WELDER / GENERATOR

MAINTENANCE

STORAGE: Store the RANGER 250 LPG in clean, dry protected areas.

CLEANING: Blow out the generator and controls peri- odically with low pressure air. Do this at least once a week in particularly dirty areas.

BRUSH REMOVAL AND REPLACEMENT: It’s nor- mal for the brushes and slip rings to wear and darken slightly. Inspect the brushes when a generator over- haul is necessary.

CAUTION

Do not attempt to polish slip rings while the engine is running.

WARNING

Service and Repair should only be performed by Lincoln Electric Factory Trained Personnel. Unauthorized repairs performed on this equip- ment may result in danger to the technician and machine operator and will invalidate your factory warranty. For your safety and to avoid Electrical Shock, please observe all safety notes and pre- cautions.

------------------------------------------------------------------------

GFCI RECEPTACLE TESTING AND RESET- TING PROCEDURE

The GFCI receptacle should be properly tested at least once every month or whenever it is tripped. To properly test and reset the GFCI receptacle:

If the receptacle has tripped, first carefully remove any load and check it for damage.

If the equipment has been shut down, it must be restarted.

The equipment needs to be operating at high idle speed and any necessary adjustments made on the control panel so that the equipment is providing at least 80 volts to the receptacle input terminals.

The circuit breaker for this receptacle must not be tripped. Reset if necessary.

Push the "Reset" button located on the GFCI recep- tacle. This will assure normal GFCI operation.

Plug a night-light (with an "ON/OFF" switch) or other product (such as a lamp) into the GFCI receptacle and turn the product "ON".

Push the "Test" button located on the GFCI recepta- cle. The night-light or other product should go "OFF".

Push the "Reset" button, again. The light or other product should go "ON" again.

If the light or other product remains "ON" when the "Test" button is pushed, the GFCI is not working prop- erly or has been incorrectly installed (miswired). If your GFCI is not working properly, contact a qualified, certified electrician who can assess the situation, rewire the GFCI if necessary or replace the device.

RANGER 250 LPG

Image 30
Contents Ranger 250 LPG Safety California Proposition 65 WarningsElectric Shock can kill Welding Sparks can cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a L’ArcThank You Table of Contents Section F Section DSection E SeriesInstallation Technical Specifications Ranger 250 LPG K2336-2Machine Specifications Ranger 250 LPG Engine K2336-2 Safety Precautions PRE-OPERATION Service FuelTighten by hand OIL Battery ConnectionRemote Control Engine Cooling SystemElectrical Connections Auxiliary Power Receptacles Standby Power ConnectionsConnection of Ranger 250 LPG to Premises GNDConnection of LN-7 or LN-8 to the Ranger 250 LPG Connection of Lincoln ELEC- Tric Wire FeedersConnection of LN-15 Wire Feeder to the Ranger 250 LPG Across-The-Arc ModelConnection of the LN-25 to the Ranger 250 LPG Connection of Prince Spool Gun to the Ranger 250 LPGOperation Design FeaturesAdditional Safety Precautions General DescriptionWeld Mode Selector Switch Welding ControlsARC Control Engine Controls Duty Cycle Welder OperationStopping Typical Ranger 250 LPG Fuel ConsumptionWire WELDING-CV TIG WeldingTypical Current Ranges 1 for Tungsten ELECTRODES2 Auxiliary Power ARC GougingRanger 250 LPG Extension Cord Length Recommendations Accessories T12153-9 50 AMP, 120/240V Power PlugRecommended Optional Equipment Maintenance Engine Maintenance ComponentsKohler Engine Engine OIL Change AIR Cleaner ServiceAIR PRE-CLEANER Service Engine OIL Refill CapacitiesSpark Plug Service AIR Filter Paper ElementSpark Plug Cleaning the Battery Engine Adjustment Overspeed is HazardousBattery Maintenance Charging the BatteryWelder / Generator Maintenance Gfci Receptacle Testing and RESET- Ting ProcedureTroubleshooting HOW to USE Troubleshooting GuideService Facility Persists,Contact your localLincoln Authorized Field Cause Course of Action Contact your local LincolnTroubleshooting Troubleshooting Diagrams Diagrams Diagrams Diagrams Diagrams Engine Welders /LN-8 Connection Diagram Diagrams Diagrams Diagrams Diagrams Diagrams Dimension Print Ranger 250 LPGRanger 250 LPG Ranger 250 LPG Precaucion Warnung