6.a. Remove fire hazards from the welding area. If this is not possible, cover them to prevent the welding sparks from starting a fire.

Remember that welding sparks and hot materials from welding can easily go through small cracks and openings to adjacent areas. Avoid welding near hydraulic lines. Have a fire extinguisher readily available.

6.b. Where compressed gases are to be used at the job site, special precautions should be used to prevent hazardous situations. Refer to “Safety in Welding and Cutting” (ANSI Standard Z49.1) and the operating information for the equipment being used.

6.c. When not welding, make certain no part of the electrode circuit is touching the work or ground. Accidental contact can cause overheating and create a fire hazard.

6.d. Do not heat, cut or weld tanks, drums or containers until the proper steps have been taken to insure that such procedures will not cause flammable or toxic vapors from substances inside. They can cause an explosion even though they have been “cleaned”. For information, purchase “Recommended Safe Practices for the Preparation for Welding and Cutting of Containers and Piping That Have Held Hazardous Substances”, AWS F4.1 from the American Welding Society (see address above).

6.e. Vent hollow castings or containers before heating, cutting or welding. They may explode.

6.f. Sparks and spatter are thrown from the welding arc. Wear oil free protective garments such as leather gloves, heavy shirt, cuffless trousers, high shoes and a cap over your hair. Wear ear plugs when welding out of position or in confined places. Always wear safety glasses with side shields when in a welding area.

6.g. Connect the work cable to the work as close to the welding area as practical. Work cables connected to the building framework or other locations away from the welding area increase the possibility of the welding current passing through lifting chains, crane cables or other alternate cir- cuits. This can create fire hazards or overheat lifting chains or cables until they fail.

6.h. Also see item 1.c.

6.I. Read and follow NFPA 51B “ Standard for Fire Prevention During Welding, Cutting and Other Hot Work”, available from NFPA, 1 Batterymarch Park,PO box 9101, Quincy, Ma 022690-9101.

6.j. Do not use a welding power source for pipe thawing.

CYLINDER may explode if damaged.

7.a. Use only compressed gas cylinders containing the correct shielding gas for the process used and properly operating regulators designed for the gas and

pressure used. All hoses, fittings, etc. should be suitable for the application and maintained in good condition.

7.b. Always keep cylinders in an upright position securely chained to an undercarriage or fixed support.

7.c. Cylinders should be located:

Away from areas where they may be struck or subjected to physical damage.

A safe distance from arc welding or cutting operations and any other source of heat, sparks, or flame.

7.d. Never allow the electrode, electrode holder or any other electrically “hot” parts to touch a cylinder.

7.e. Keep your head and face away from the cylinder valve outlet when opening the cylinder valve.

7.f. Valve protection caps should always be in place and hand tight except when the cylinder is in use or connected for use.

7.g. Read and follow the instructions on compressed gas cylinders, associated equipment, and CGA publication P-l, “Precautions for Safe Handling of Compressed Gases in Cylinders,” available from the Compressed Gas Association 1235 Jefferson Davis Highway, Arlington, VA 22202.

FOR ELECTRICALLY powered equipment.

8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment.

8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturerʼs recommendations.

8.c. Ground the equipment in accordance with the U.S. National Electrical Code and the manufacturerʼs recommendations.

Jan, 07

Image 4
Contents Vantage Safety California Proposition 65 WarningsElectric Shock can kill Welding and Cutting Sparks can Cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a LʼArcThank You Table of Contents Section D Section ESection F 528Installation Technical Specifications Vantage 400 K2410-1 K2410-2VRD Voltage Reduction Device Safety PrecautionsLocation and Ventilation PRE-OPERATION Engine Service High Temperature OperationTowing Vehicle MountingBattery Connection Remote ControlOIL FuelElectrical Connections Machine GroundingWelding Output Cables Total Combined Length of Electrode and Work CablesStandby Power Connections Auxiliary Power ReceptaclesGfci Duplex Receptacles Connection of Vantage 400 to Premises Wiring Connection of Lincoln Electric Wire Feeders Connection of LN-15 to the Vantage Shut the welder offAcross The-Arc Model Control Cable ModelConnection of Prince XL Spool GUN to the Vantage Operation General DescriptionWeld Mode Selector Switch Figure B.1Wire Feeder Voltmeter Switch Table B.1Engine Controls Glow Plug Push ButtonStarting the Engine Table B.2Stopping the Engine Welder OperationDuty Cycle Electrode InformationTypical Current Ranges 1 for Tungsten ELECTRODES2 TIG WeldingTable B.3 Auxiliary Power Wire WELDING-CVARC Gouging Accessories Field Installed Options / ACCES- SoriesWire Feeder Options TIG OptionsMaintenance Routine MaintenanceEngine OIL Change AIR CleanerOIL Filter Change Maintenance Tightening the FAN Belt Cooling SystemBleeding the Fuel System Engine Adjustment Battery MaintenanceServicing Optional Spark ArrestorWelder / Generator Maintenance Gfci Receptacle Testing and RESET- Ting ProcedureTroubleshooting HOW to USE Troubleshooting GuideLincoln Authorized Field Service FacilityContact your local Lincoln Welding without a control cable Troubleshooting Faulty control cable. Repair or Field Service Facility Your local Lincoln AuthorizedDiagrams Diagrams Diagrams Diagrams Diagrams Diagrams Diagrams Diagrams Diagrams Diagram Wiring400 Dimension PrintPrecaucion Warnung