Lincoln Electric IM622 manual Mounting the LFA 3.1 or 4.1 ARM to the WALL-MOUNTING Bracket

Page 12

A-5

INSTALLATION

A-5

 

 

 

INSTALLING WITh AN LFA 10FT. OR 13FT. WALL-MOUNTED PACKAGE

(continued)

MOUNTING THE LFA 3.1 OR 4.1 ARM TO THE WALL-MOUNTING BRACKET

Leave the tape and plastic packaging on the extrac- tion arm sections until the arm is completely installed (including mounting the hood). The arm is spring-bal- anced to compensate for the weight of the hood and will spring out quickly if it is not mounted securely, with the hood in place.

The rotating hinge of the arm comes in three pieces: Metal rotating hinge, red plastic ring, and clamping pin. Refer to Figure 3. Mount the red plastic ring to the metal rotating hinge by fitting the clamping pin through the hole in the rotating rod, and snapping it into place on the U-shaped indents on the red plastic ring. The lip of the ring should fit securely against the top edge of the rotating flange, yet rotate with the rod. The assembly should look like Part C in Figure 4.

2

1

3

Fig. 3

Position the rotating hinge on the wall mounting brack- et (See Fig. 4) so that the cable hole (Fig. 4A) is on the wall side and the long side of the pin (Fig. 4B) is in the front. Use the four 3” bolts with washers and nuts to secure the rotating hinge.

C

A

B

Mount the hanging adapter (Fig. 5D) to the hinge rod (Fig. 5C) using (2) 1.75” bolts with washers and nuts. Mount the spring bracket (Fig. 5F) into the two holes as shown. Position one 8” rubber seal (Fig. 5A) on the red plastic ring. Roll the bottom half up and slide the connecting hose (Fig. 5E) over the bottom of the red plastic ring. Roll the bottom of the rubber seal down over the end of the connection hose.

A

B

C

D

E

F

Fig. 5

Put another rubber band on the base of the arm. Use

(2)1.75” bolts with nuts to mount the arm (Fig. 6B) to the hanging adapter (Fig. 6A), using both mounting holes as shown in the inset of Figure 6.

A B

Fig. 6

D

Fig. 4

E

SF2400 STATIONARY FAN

Image 12
Contents Safety Depends on You SF2400 Stationary FANSafety California Proposition 65 WarningsElectric Shock can kill IiiSAFETY IiiIvSAFETY Précautions DE SûretéThank You Identification plate specifiesTAbLE of Contents Installation Min. TemperatureMax. Temperature Max. Rel. humidityPressure Drop Safety Precautions General DescriptionElectric ShOCK can kill Moving Parts can injureInstallation Mounting the LFA 3.1 or 4.1 ARM to the WALL-MOUNTING Bracket Mounting the SF2400 FAN to the Wall Mounting Bracket Installing WITh AN LTA 2.0, 3-5 FT. Telescopic ARM Mounting the MOTOR-MOUNTING Bracket and Telescopic ARMMounting the Extraction FAN to the Motor Mounting Bracket Installing WITh AN LTA 2.0, 3-5 FT. Telescopic Package Installing ThE Silencer Installing ThE Optional Statiflex 200-MInstalling ThE STARTER/OVER- Load SWITCh If installing with an LTA 2.0 Telescopic Arm Installing ThE Optional If installing with a 10 ft. or 13 ft. ArmLamp KIT and Automatic START/STOP ARC Sensor Please Note Safety Instructions OperationOperating Instructions Fumes and Gases can be dangerousMaintenance Routine MaintenanceTROUbLEShOOTING Diagrams STARTER/OVERLOAD Switch FAN MotorFAN Motor SF2400 Stationary FAN Warnung Precaucion