INSTALLATION | ||
|
|
|
INSTALLING ThE SILENCER
The
The
•Air Exhaust Silencer, with 6” (160 mm) connections
•Elbow, 90˚, with 6” (160 mm) connections
•(2) Fittings, to fit on the OD of the:
Outlet of the SF2400 Fan
Elbow, 90˚
Air Exhaust Silencer
Install the silencer and the connecting ductwork into the outlet of the fan. If venting extracted air outside, apply the supplied ductwork between the fan and silencer, then use 160 mm (6.3 in.) ductwork or flexi- ble hose to route the exhausted air outside through a hole in the wall or roof.
INSTALLING ThE OPTIONAL STATIFLEX 200-M
The Statiflex
E
D
A B C
The
•Complete Filter Unit, with filter installed and inlet(s) and outlet(s) sealed
•Reducer,
•8” Connection hose, 4 ft. long
•(2) 8” Hose Clamps
Fit the small (6” diam.) side of the
Fit one end of the 8” Connection hose (See B) over the larger side of the
Mount the Statiflex mounting bracket (Fig. 17A) to the wall where convenient with the following in mind:
A
11.4"
(290 mm) Fig. 17
•Access to the filter (for maintenance) is by lifting the large red cover over the (internal) filter. The easiest method is to lift the entire filter unit off the mounting bracket (about
•The 8” connection hose must reach (comfortably) the inlet of the Statiflex
•The Statiflex
•Recommended mounting height of the Statiflex mounting bracket is less than 7 ft. from the floor to the drilled holes. It is recommended to mount the bracket about
Before lifting the Statiflex
• Cut the left inlet (or right, depending on which side of the fan it is to be mounted) open (See C). A hack- saw or
•Unscrew the thumb nut and remove the filter cover (See D). Cut one or both outlet openings (See E) open. Replace the filter cover and thumb nut.
Lift the Statiflex
A B C
E
D
Fig. 18
SF2400 STATIONARY FAN