Lincoln Electric IM622 manual FAN Motor

Page 26

WIRING DIAGRAM FOR SF2400 FAN WITh K1669-2 LAMP KIT

E-2

DIAGRAMS

E-2

 

 

 

NOTES:

N.A. MOUNT THERMAL RELAY TO CONTACTOR AS DESCRIBED IN INSTALLATION SECTION.

N.B. TO INSERT CONDUCTORS IN TERMINAL BLOCK, PUSH IN ON FRONT OPENING

WITH SMALL SCREWDRIVER, AND INSERT WIRE IN CORRESPONDING TOP OPENING.

N.C. LAMP WIRES ARE WHITE WITH BLACK SLEEVES.

N.D. WIRES LABELED L, N, AND GND TO BE PROVIDED AND INSTALLED BY CUSTOMER.

L

 

 

 

 

 

 

 

 

 

 

BN

 

CONTROL

 

 

 

 

 

 

 

 

 

 

 

BOX

N

 

 

 

 

 

 

 

L

 

N

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TRANSFORMER

 

A1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SEC. 24V

BK

1L1

3L2

5L3

 

21

 

 

CONTACTOR

 

 

 

 

 

 

 

 

01E

 

 

 

TR 188.83

 

 

1

3

4

AEG

 

 

 

 

 

SERIE: 9740

 

 

 

 

 

 

 

 

 

 

 

 

 

Primair

 

 

 

 

 

 

 

 

 

 

 

0

115V

230V

400V

BN

 

 

 

 

 

 

BN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GN

 

 

 

 

 

 

GN

 

 

 

 

48VA

BK

1

3

4

 

 

N.A.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2T1

4T2

6T3

 

22

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BN

 

BN

 

BK

BK

BK

 

A2

 

 

 

BL

 

 

A2

 

 

 

 

 

THERMAL RELAY

 

 

 

BL

 

 

 

 

 

 

RD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b27T

AEG

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WH

 

 

 

 

 

AUTO

 

 

 

 

 

 

 

 

 

 

 

 

MAN

 

 

 

 

 

 

BN

 

BN

N.B.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GN

 

 

 

 

BN

 

 

 

96

98

97

95

 

 

BN

 

GN

 

 

 

 

 

 

 

 

GN/YE

 

 

 

 

 

 

RD

 

 

 

 

 

 

 

 

 

 

 

 

BN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WH

BN

GN

GN/YE

 

 

T1

T2

T3

 

 

N.A.

 

BL

 

BL

 

 

 

 

 

 

 

N.B.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BN

 

 

BN

BK

 

 

 

 

 

 

 

 

BK

 

 

 

 

 

 

 

 

 

N.B.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GN/YE

 

GND

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N.D.

 

 

 

GROUND

BN

 

BN

 

 

 

 

 

 

 

 

 

LUG

FUSE

WH

GN

 

 

 

 

 

 

 

 

 

 

L

 

 

 

 

GND

 

 

 

 

 

 

 

 

N

 

 

 

 

L

 

 

 

 

 

 

 

 

 

 

 

 

N

GND

 

N

L

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AUTO START/STOP

 

36

 

GND

 

 

N.D.

INPUT POWER

 

 

 

 

 

 

GND

ARC SENSOR

 

 

 

 

 

 

FT

 

N

 

 

N

115V/1PH/60HZ

 

BN

WH

N.D.

 

L

L

 

 

 

 

 

 

 

 

 

 

 

.

 

 

 

 

 

 

 

 

GN

 

CABLE

L

FAN MOTOR

 

 

 

LAMP

 

 

See motor (terminal cover) for

 

 

N

wiring instructions that pertain

 

 

 

 

N.C.

 

 

N.D.

to the specific motor type.

BK BK

WH BN GN

 

 

 

LAMP

 

 

 

 

I/O

GN

BN GN

WIRE COLOR CONVENTIONS

 

BN

BN - Brown

L - Line (115VAC/1PH/60HZ)

 

WH

WH

BL - Blue

REMOTE SWITCH

 

BK - Black

N - Neutral

 

GN - Green

GND - Ground

WORK LAMP

 

WH - White

 

 

GND - Green/Yellow

SF2400 STATIONARY FAN

Image 26
Contents Safety Depends on You SF2400 Stationary FANSafety California Proposition 65 WarningsElectric Shock can kill IiiSAFETY IiiIvSAFETY Précautions DE SûretéThank You Identification plate specifiesTAbLE of Contents Max. Temperature InstallationMin. Temperature Max. Rel. humidityPressure Drop Electric ShOCK can kill Safety PrecautionsGeneral Description Moving Parts can injureInstallation Mounting the LFA 3.1 or 4.1 ARM to the WALL-MOUNTING Bracket Mounting the SF2400 FAN to the Wall Mounting Bracket Installing WITh AN LTA 2.0, 3-5 FT. Telescopic ARM Mounting the MOTOR-MOUNTING Bracket and Telescopic ARMMounting the Extraction FAN to the Motor Mounting Bracket Installing WITh AN LTA 2.0, 3-5 FT. Telescopic Package Installing ThE Silencer Installing ThE Optional Statiflex 200-MInstalling ThE STARTER/OVER- Load SWITCh If installing with an LTA 2.0 Telescopic Arm Lamp KIT and Automatic START/STOP ARC Sensor Installing ThE OptionalIf installing with a 10 ft. or 13 ft. Arm Please Note Operating Instructions Safety InstructionsOperation Fumes and Gases can be dangerousMaintenance Routine MaintenanceTROUbLEShOOTING Diagrams STARTER/OVERLOAD Switch FAN MotorFAN Motor SF2400 Stationary FAN Warnung Precaucion