Lincoln Electric IM622 manual Mounting the SF2400 FAN to the Wall Mounting Bracket

Page 13

A-6

INSTALLATION

A-6

 

 

 

INSTALLING WITh AN LFA 10FT. OR 13FT. WALL-MOUNTED PACKAGE

(continued)

MOUNTING THE LFA 3.1 OR 4.1 ARM TO THE WALL-MOUNTING BRACKET

(continued)

Position one 8” rubber seal (Fig. 7B) and the flexible hose supplied with the arm (Fig. 7C) on the hood end of the arm (Fig. 7A). Put the last rubber seal on the hood connection. Mount the friction block into the U- section, using one bolt and nut as shown in Figure 7.

A

B

C

D

Fig. 7

Snap the hose running guard into place atop the mid- dle hinge section so the “nose” end faces the base of the arm as shown in Figure 8.

C(2x)

Fig. 8

Remove the plastic and tape from the arm sections. Adjust the friction of the arm and hood movement as described in the Maintenance Section of the LFA Extraction Arm Manual.

MOUNTING THE SF2400 FAN TO THE WALL MOUNTING BRACKET

Use the (2) 0.75” bolts and the (2) 2.5” bolts with washers supplied with the fan to mount the fan (Fig. 9B) to the rotating hinge (Fig. 9C) as shown. Tighten all mounting bolts firmly to make the seal at the inlet of the fan.

A

B

C

Fig. 9

The K1494-2 Starter/Overload Switch or K1669-2 Lamp Kit must be installed to provide power to the fan. Refer to the appropriate Installation section in this manual for details.

SF2400 STATIONARY FAN

Image 13
Contents SF2400 Stationary FAN Safety Depends on YouCalifornia Proposition 65 Warnings SafetyElectric Shock can kill Iii IiiSAFETYPrécautions DE Sûreté IvSAFETYIdentification plate specifies Thank YouTAbLE of Contents Min. Temperature InstallationMax. Temperature Max. Rel. humidityPressure Drop General Description Safety PrecautionsElectric ShOCK can kill Moving Parts can injureInstallation Mounting the LFA 3.1 or 4.1 ARM to the WALL-MOUNTING Bracket Mounting the SF2400 FAN to the Wall Mounting Bracket Mounting the MOTOR-MOUNTING Bracket and Telescopic ARM Installing WITh AN LTA 2.0, 3-5 FT. Telescopic ARMMounting the Extraction FAN to the Motor Mounting Bracket Installing WITh AN LTA 2.0, 3-5 FT. Telescopic Package Installing ThE Optional Statiflex 200-M Installing ThE SilencerInstalling ThE STARTER/OVER- Load SWITCh If installing with an LTA 2.0 Telescopic Arm If installing with a 10 ft. or 13 ft. Arm Installing ThE OptionalLamp KIT and Automatic START/STOP ARC Sensor Please Note Operation Safety InstructionsOperating Instructions Fumes and Gases can be dangerousRoutine Maintenance MaintenanceTROUbLEShOOTING STARTER/OVERLOAD Switch FAN Motor DiagramsFAN Motor SF2400 Stationary FAN Warnung Precaucion