INSTALLATION | ||
|
|
|
INSTALLING WITh AN LTA 2.0, 3-5 FT. TELESCOPIC ARM
WARNING
The installer is responsible for following local safety codes and regulations.
Before drilling, verify locations of existing gas, water, or electrical conduits.
•Telescopic arm, assembled
•(1) Flexible hose, (2) 8” Rubber seals for connection to fan
8.3" (210 mm) 6.3" (160 mm)
9" (230 mm)
Fig. 11
•(2) Bracket pieces
•Tapered Connection Flange
•8” Hose Clamp
•SF2400 Stationary Fan
•(2) Bolts, M8x1.25, 20mm long (about 0.75”)
•(2) Bolts, M8x1.25, 65mm long (about 2.50”)
•(4) Washers, M8
Note:
MOUNTING THE MOTOR-MOUNTING BRACKET AND TELESCOPIC ARM
0.4" (10 mm)
ø0.5" (ø13 mm)
9"
(230 mm)
8.3"
(210 mm)
10"
(255 mm)
Fig. 12
4.7"
(120 mm)
Disconnect the telescopic mounting bracket from the arm before mounting, by removing the 1.75” bolt (Fig. 12C), and sliding the post out of the friction block.
A
Drill (5) holes (Reference Figures 11, 12, 13).
Mount the motor mounting bracket and the telescopic mounting bracket to the wall. Standard mounting height is 5 ft., 3 in. (1300 mm) from the work table to the post of the telescopic mounting bracket. Refer to Figures 11 and 12 for drilling dimensions.
Refer to Figure 2 for information on mounting methods for installation on various wall types.
C B
Fig. 10 | Fig. 13 |
SF2400 STATIONARY FAN