Lincoln Electric IM640-A manual Safety, California Proposition 65 Warnings

Page 2

i

SAFETY

i

WARNING

CALIFORNIA PROPOSITION 65 WARNINGS

Diesel engine exhaust and some of its constituents are known to the State of California to cause can- cer, birth defects, and other reproductive harm.

The Above For Diesel Engines

The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm.

The Above For Gasoline Engines

ARC WELDING CAN BE HAZARDOUS. PROTECT YOURSELF AND OTHERS FROM POSSIBLE SERIOUS INJURY OR DEATH. KEEP CHILDREN AWAY. PACEMAKER WEARERS SHOULD CONSULT WITH THEIR DOCTOR BEFORE OPERATING.

Read and understand the following safety highlights. For additional safety information, it is strongly recommended that you purchase a copy of “Safety in Welding & Cutting - ANSI Standard Z49.1” from the American Welding Society, P.O. Box 351040, Miami, Florida 33135 or CSA Standard W117.2-1974. A Free copy of “Arc Welding Safety” booklet E205 is available from the Lincoln Electric Company, 22801 St. Clair Avenue, Cleveland, Ohio 44117-1199.

BE SURE THAT ALL INSTALLATION, OPERATION, MAINTENANCE AND REPAIR PROCEDURES ARE PERFORMED ONLY BY QUALIFIED INDIVIDUALS.

FOR ENGINE powered equipment.

1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running.

____________________________________________________

1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes

outdoors.

____________________________________________________

1.c. Do not add the fuel near an open flame weld- ing arc or when the engine is running. Stop the engine and allow it to cool before refuel- ing to prevent spilled fuel from vaporizing on contact with hot engine parts and igniting. Do not spill fuel when filling tank. If fuel is spilled, wipe it up and do not start engine until fumes

have been eliminated.

____________________________________________________

1.d. Keep all equipment safety guards, covers and devices in posi- tion and in good repair.Keep hands, hair, clothing and tools away from V-belts, gears, fans and all other moving parts when starting, operating or repairing equipment.

____________________________________________________

1.e. In some cases it may be necessary to remove safety guards to perform required maintenance. Remove guards only when necessary and replace them when the maintenance requiring their removal is complete. Always use the greatest care when working near moving parts.

___________________________________________________

1.f. Do not put your hands near the engine fan. Do not attempt to override the governor or idler by pushing on the throttle control rods

while the engine is running.

___________________________________________________

1.g. To prevent accidentally starting gasoline engines while turning the engine or welding generator during maintenance work, disconnect the spark plug wires, distributor cap or magneto wire as appropriate.

1.h. To avoid scalding, do not remove the radiator pressure cap when the engine is hot.

ELECTRIC AND MAGNETIC FIELDS may be dangerous

2.a. Electric current flowing through any conductor causes localized Electric and Magnetic Fields (EMF). Welding current creates EMF fields around welding cables and welding machines

2.b. EMF fields may interfere with some pacemakers, and welders having a pacemaker should consult their physician before welding.

2.c. Exposure to EMF fields in welding may have other health effects which are now not known.

2.d. All welders should use the following procedures in order to minimize exposure to EMF fields from the welding circuit:

2.d.1. Route the electrode and work cables together - Secure them with tape when possible.

2.d.2. Never coil the electrode lead around your body.

2.d.3. Do not place your body between the electrode and work cables. If the electrode cable is on your right side, the work cable should also be on your right side.

2.d.4. Connect the work cable to the workpiece as close as possible to the area being welded.

2.d.5. Do not work next to welding power source.

Mar ‘95

Image 2
Contents IM640-A Safety California Proposition 65 WarningsElectric Shock can kill Cylinder may explode if damaged Précautions DE Sûreté Sûreté Pour Soudage a L’ArcSafety Safety Thank You Table of Contents Height Width Depth Weight InstallationTechnical Specifications SAE400 & SAE400 WELD’N AIR Stacking Safety PrecautionsLOCATION/VENTILATION Angle of OperationTowing PRE-OPERATION Engine and Compressor ServiceHigh Altitude Operation Vehicle MountingEngine BREAK-IN Period Battery ConnectionEngine Cooling System Machine Grounding Welding Output CablesSpark Arrester Operation Safety InstructionsAdditional Safety Precautions Operating InstructionsDuty Cycle Design Features and AdvantagesRecommended Applications Engine Controls Welder ControlsAIR Compressor Controls SAE400 WELD’N AIR only Starting Instructions Engine OperationTypical Fuel Consumption Cold Weather StartingK1690-1 Gfci Receptacle KIT AccessoriesK2303-1 Sheet Metal KIT Routine Maintenance MaintenancePeriodic Maintenance Compressor AIR Receiver Tanks SAE400 WELD’N AIR onlyPRE Filter / Washer Separator Commutator and Brush MaintenanceFuel PRE-FILTER/WATER Separator Assembly Cooling SystemWater Separator Element Spark Arrestor Troubleshooting HOW to USE Troubleshooting GuideSymptoms Course of Action Function ProblemsRecommended Troubleshooting Problems Possible Cause Recommended Wiring Diagrams Wiring Diagram SAE-400 Weldn AIRWiring Diagram SAE-400 Perkins Control Wiring Diagram SAE-400 & Weldn AIR Dimension Print SAE400 & SAE400 WELD’NSAE400 & SAE400 WELD’N AIR Aviso DE Warnung