Lincoln Electric IM640-A manual AIR Compressor Controls SAE400 WELD’N AIR only

Page 18

B-4

OPERATION

B-4

 

 

 

How to Set the Controls

Assume you want a normal soft arc and about 135 amps, using a 5/32” (4.0 mm) electrode:

1.Set the “Job Selector” at the center of the black range.

2.Set the “Current Control” to read 135 amps on the black dial.

3.Start to weld.

4.If you want a little more current, turn the “Job Selector” up (counterclockwise) to increase cur- rent. If you want a little less current, turn the “Job Selector” down (clockwise) to decrease current.

5.If dialing the desired current with the “Job Selector” moves the setting outside the black range causing undesirable arc characteristics, turn the “Job Selector” back to the center of the black range. Then turn the “Current Control” up or down a little as needed. Readjust the “Job Selector” for the exact characteristics and current desired.

REMOTE CONTROL

A receptacle and “Local/Remote” control switch on the lower front control panel and a remote control box with 100 ft. (30.5 m) of cord for adjusting the OCV at the welding site are standard. Putting the switch in the “REMOTE” position allows fine current control at the remote control box while placing the switch in the “LOCAL” position allows fine current control at the “Job Selector” on the machine. When using the optional field installed CV adapter (K385-1) the “Local/Remote” switch is only active in the “VV” mode.

AUXILIARY POWER CONTROLS

115 VAC Receptacle

One 20 amp, 115 VAC duplex receptacle provides 115 VAC for auxiliary power. A total of 26 amps can be drawn from this receptacle.

230 VAC Receptacle

One 15 amp, 230 VAC duplex receptacle provides 230 VAC for auxiliary power. A total of 13 amps can be drawn from this receptacle.

Circuit Breakers

The circuit breakers provide separate overload current protection for each half of the 115 V duplex receptacle. The circuit breakers provide overload current protec- tion in both current carrying wires of the 230 V duplex receptacle.

Ground Stud

Provides a connection point for connecting the machine to earth ground. For the safest grounding pro- cedure refer to “Machine Grounding” in the INSTALLA- TION section of this manual.

AIR COMPRESSOR CONTROLS - (SAE400 WELD’N AIR ONLY)

COMPRESSOR ON/OFF SWITCH

Placing the “ON/OFF” switch in the “ON” position allows the “pressure switch” (factory preset) to control the air compressor through an electric clutch. When the system pressure falls below 90 psi, the “pressure switch” engages the clutch and compressor. When the system pressure goes above 130 psi, the “pressure switch” disengages the clutch and compressor.

The “ON/OFF” switch needs to be in the “ON” position when using compressed air. When placed in the “OFF” position this switch does not allow the compressor clutch to engage regardless of the tank pressure.

The “ON/OFF” switch should be in the “OFF” position while starting the engine. This will minimize the load on the starter motor.

COMPRESSOR OPERATING LIGHT

This light is on when the compressor “ON/OFF” switch is in the “ON” position.

COMPRESSOR AIR PRESSURE GAUGE

This gauge displays the air pressure in the air receiver tanks.

COMPRESSOR OIL PRESSURE GAUGE

This gauge displays the compressor oil pressure. Oil is under pressure only when the compressor clutch is engaged.

SAE400 & SAE400 WELD’N AIR

Image 18
Contents IM640-A Safety California Proposition 65 WarningsElectric Shock can kill Cylinder may explode if damaged Précautions DE Sûreté Sûreté Pour Soudage a L’ArcSafety Safety Thank You Table of Contents Installation Technical Specifications SAE400 & SAE400 WELD’N AIRHeight Width Depth Weight Stacking Safety PrecautionsLOCATION/VENTILATION Angle of OperationTowing PRE-OPERATION Engine and Compressor ServiceHigh Altitude Operation Vehicle MountingBattery Connection Engine Cooling SystemEngine BREAK-IN Period Welding Output Cables Spark ArresterMachine Grounding Operation Safety InstructionsAdditional Safety Precautions Operating InstructionsDesign Features and Advantages Recommended ApplicationsDuty Cycle Engine Controls Welder ControlsAIR Compressor Controls SAE400 WELD’N AIR only Starting Instructions Engine OperationTypical Fuel Consumption Cold Weather StartingAccessories K2303-1 Sheet Metal KITK1690-1 Gfci Receptacle KIT Routine Maintenance MaintenancePeriodic Maintenance Compressor AIR Receiver Tanks SAE400 WELD’N AIR onlyPRE Filter / Washer Separator Commutator and Brush MaintenanceFuel PRE-FILTER/WATER Separator Assembly Cooling SystemWater Separator Element Spark Arrestor Troubleshooting HOW to USE Troubleshooting GuideSymptoms Course of Action Function ProblemsRecommended Troubleshooting Problems Possible Cause Recommended Wiring Diagrams Wiring Diagram SAE-400 Weldn AIRWiring Diagram SAE-400 Perkins Control Wiring Diagram SAE-400 & Weldn AIR Dimension Print SAE400 & SAE400 WELD’NSAE400 & SAE400 WELD’N AIR Aviso DE Warnung