| TROUBLESHOOTING | ||
|
|
|
|
| Observe all Safety Guidelines detailed throughout this manual | ||
|
|
|
|
| PROBLEMS | POSSIBLE | RECOMMENDED |
| (SYMPTOMS) | CAUSE | COURSE OF ACTION |
|
|
|
|
FUNCTION PROBLEMS
No auxiliary power
1. | Circuit Breakers open. | 1. | Check and reset breakers. If |
|
|
| breakers keep tripping check con- |
|
|
| nections to auxiliary receptacles. |
|
|
| Also make sure load does nor |
|
|
| exceed receptacleʼs current rating. |
2. | Faulty connections to auxiliary | 2. | Check connections. |
| receptacles. |
|
|
3. | GFCI Receptacle (if installed) may | 3. | Follow “GFCI Receptacle Testing |
| have tripped. |
| and Resetting Procedure” in the |
|
|
| MAINTENANCE section of this |
|
|
| manual. |
|
|
|
|
CAUTION