Lincoln Electric IM869-D manual Installation, Technical Specifications SAE-400 K1278-7, K1278-9

Page 8

A-1

 

 

 

 

 

INSTALLATION

 

 

 

A-1

 

 

 

 

 

 

 

 

 

 

 

 

TECHNICAL SPECIFICATIONS - SAE-400 (K1278-7, K1278-9)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INPUT - DIESEL ENGINE

 

 

 

 

Make/Model

 

Description

 

Speed (RPM)

Displacement

Starting

 

Capacities

 

 

 

 

 

 

 

 

System

 

 

 

 

 

 

 

 

 

 

 

 

 

K1278-7

 

 

 

 

 

 

 

 

 

 

Perkins

 

4 cylinder

 

High Idle 1800

269 cu. in

12VDC batteries

 

Fuel: 22.5 gal.

1104C-44 Diesel

 

68.4 HP @

 

Low Idle 1100

(4.4 L)

(2) & Starter

 

85.1 L

Engine

 

1725 RPM

 

Full Load 1725

 

 

 

 

 

EPA Tier II

 

 

 

 

 

 

 

 

 

 

Compliant

 

 

 

 

 

Bore x Stroke

 

 

 

Oil: 10.1 Qts.

 

 

 

 

 

 

 

 

 

 

 

9.6 L

K1278-9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Perkins

 

4 cylinder

 

 

4.13” x 5.00”

 

 

 

 

1104A-44 Diesel

 

64.4 HP @

 

 

(105.0 mm x 127.0mm)

 

 

 

Coolant: 3.4 gal.

Engine

 

1710 RPM

 

 

 

 

 

 

12.8 L

Not EPA Tier II

 

 

 

 

 

 

 

 

 

 

Compliant

 

 

 

 

 

 

 

 

 

 

(Export Only)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RATED OUTPUT - WELDER

 

 

 

 

Duty Cycle (1)

 

 

 

Welding Output

 

Volts at Rated Amps

35% (NEMA)

 

 

 

500 amps

 

 

 

40 volts

100% (NEMA)

 

 

 

400 amps

 

 

 

36 volts

100% (Lincoln Plus)

 

 

400 amps

 

 

 

40 volts

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUT - WELDER AND GENERATOR

Welding Range

80 - 575 Amps

Open Circuit Voltage

97 Max. OCV @ 1800 RPM

Auxiliary Power

115/230 VAC

3000 Watts, 60 Hz.

100% Duty Cycle

PHYSICAL DIMENSIONS

 

 

 

 

HEIGHT

WIDTH

DEPTH

WEIGHT

50.13 in.

28.00 in.

83.00 in.

2157lbs.

1273.3 mm

711.2 mm

2108.2 mm

978.4kg

 

 

 

 

(1)Based on a 10 minute period.

SAE-400

Image 8
Contents IM869-D Safety California Proposition 65 WarningsElectric Shock can kill Welding and Cutting Sparks can Cause fire or explosion Précautions DE Sûreté Sûreté Pour Soudage a LʼArcThank You Table of Contents Height Width Depth Weight InstallationTechnical Specifications SAE-400 K1278-7, K1278-9 Safety Precautions LOCATION/VENTILATIONStacking Angle of OperationPRE-OPERATION Engine Service High Altitude OperationTowing Vehicle MountingEngine BREAK-IN Period Battery ConnectionEngine Cooling System Spark Arrester Welding Output CablesMachine Grounding Table A.1 Combined Length of Electrode Work CablesSafety Instructions Additional Safety PrecautionsOperation Operating InstructionsDuty Cycle Design Features and AdvantagesRecommended Applications Engine Controls Welder ControlsRemote Control Auxiliary Power ControlsEngine Operation Starting InstructionsStopping the Engine Cold Weather StartingTypical Fuel Consumption Perkins 1104C-44 Perkins 1104A-44Accessories K1690-1 Gfci Receptacle KITMaintenance Routine MaintenancePeriodic Maintenance Bearing MaintenanceCommutator and Brush Maintenance Fuel PRE-FILTER/WATER Separator AssemblyPRE Filter / Water Separator Cooling SystemFuel PRE-FILTER/WATER Separator Assembly Water Separator ElementSAE-400 with integral spark arresting mufflers Gfci Receptacle Testing and RESET- Ting ProcedureSpark Arrestor Troubleshooting HOW to USE Troubleshooting GuideSymptoms Course of ActionRecommended Troubleshooting Problems Possible Recommended Wiring Diagrams Wiring Diagram SAE400 Wiring Diagram Dimension Print M8869-36SAE-400 SAE-400 Aviso DE Warnung