Lincoln Electric F355I manual Safety Precautions, Select Suitable Location

Page 11

A-2

INSTALLATION

A-2

 

 

 

SAFETY PRECAUTIONS

WARNING

ELECTRIC SHOCK can kill.

Turn the input power off at the dis- connect switch before attempting to connect or disconnect input power lines, output cables or con- trol cables

Only qualified personnel should perform this installation.

Connect the green lead of the power cord to ground per National Electrical Code.

----------------------------------------------------------------------

CAUTION

Incorrect connection may result in equipment damage.

-----------------------------------------------------------------------

POWER CORD CONNECTION

A 7ft. (2m) power cord is provided and wired into the machine. Follow the power cord connection instruc- tions.

SELECT SUITABLE LOCATION

The Invertec POWER WAVE F355i will operate in harsh environments. Even so, it is important that sim- ple preventative measures are followed in order to assure long life and reliable operation.

The machine must be located where there is free cir- culation of clean air such that air movement in the back, out the sides and bottom will not be restricted.

Dirt and dust that can be drawn into the machine should be kept to a minimum. Failure to observe these precautions can result in excessive operating temperatures and nuisance shutdown.

Keep machine dry. Shelter from rain and snow. Do not place on wet ground or in puddles.

DO NOT MOUNT OVER COMBUSTIBLE SURFACES.

CAUTION

Where there is a combustible surface directly under stationary or fixed electrical equipment, that surface shall be covered with a steel plate at least .06”(1.6mm) thick, which shall extend not less than 5.90”(150mm) beyond the equipment on all sides.

-----------------------------------------------------------------------

STACKING

POWER WAVE F355i can not be stacked.

TILTING

Place the machine directly on a secure, level surface or on a recommended undercarriage. The machine may topple over if this procedure is not followed.

INPUT AND GROUNDING CONNECTIONS

Only a qualified electrician should connect the Invertec POWER WAVE F355i. Installation should be made in accordance with the appropriate National Electrical Code.

BLACK

GREEN/YELLOW

BLUE

BROWN

Three Phase Input

Connect green lead to ground per National Electric Code.

Connect black, red and white leads to power.

POWER WAVE F355i (CE)

Image 11
Contents Power Wave F355i CE California Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding Sparks can cause fire or explosionPrécautions DE Sûreté Electromagnetic Compatibility EMC Safety On-Line Product Registration ViiPlease Examine Carton and Equipment For Damage Immediately Table of Contents Power Wave F355i CE InstallationSelect Suitable Location Safety PrecautionsVoltage Sensing Output CABLES, Connections and LimitationsNegative Electrode Polarity Table A.1 Power Wave / Power Feed Wire Feeder InterconnectionsControl Cable Specifications High Speed Gear BOXFeed Head Board DIP Switch DIP Switch Settings and LocationsControl Board DIP Switch RS232 Receptacle Wire Feeder ReceptacleVoltage Sense Receptacle PIN LEAD# FunctionRequired Equipment OperationRecommended Processes Duty Cycle and Time Period Connector Status Lights Per Fig B.1Power Wave F355i CE LimitationsMaking a Weld Nominal ProceduresFringe Procedures Current Constant Voltage WeldingPulse Welding PULSE-ON-PULSE GMAW-PPRecommended Welding Procedures for Power Mode Table B.1 Power ModeCompatible Lincoln Equipment 1ACCESSORIESC-1Factory Installed Field InstalledExploding Parts can cause injury MaintenanceCapacitor Discharge Procedure Always wear a face shield and long sleeves when servicingHOW to USE Troubleshooting Guide TroubleshootingUsing the Status LED to Error Code # Indication Error Codes for the Power WaveContact your local Lincoln Troubleshooting GuideAuthorized Field Service Facility Problems Voltage setting. In the MIG/MAG Your local Lincoln Authorized Field Service FacilityF355i CE PowerWave F355i CE PowerConnection Diagram Dimension Print Power Wave F355i CE Precaucion Warnung