Lincoln Electric F355I manual Voltage Sense Receptacle, PIN LEAD# Function, RS232 Receptacle

Page 15

A-6

 

INSTALLATION

 

 

 

 

 

 

A-6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WELDING WITH MULTIPLE POWER

 

 

 

 

 

 

 

I / O RECEPTACLE SPECIFICATIONS

WAVES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

14-Pin Robotic Wire Feeder Connector

 

 

 

 

 

 

 

 

CAUTION

 

 

 

 

 

 

 

 

Pin

 

 

Lead

 

 

Function

 

 

 

 

 

 

A

 

539

 

 

Motor +

 

 

 

 

 

 

 

 

 

Special care must be taken when more than one

 

B

 

541

 

 

Motor -

 

Power Wave is welding simultaneously on a single

 

C

 

521

 

 

Solenoid +

 

D

 

522

 

 

Solenoid common

part. Arc blow and arc interference may occur or

 

 

 

 

 

E

 

845

 

 

Tach 2A Differential Signal

be magnified.

 

 

 

 

 

 

 

 

 

F

 

847

 

 

Single Tach input

-----------------------------------------------------------------------

 

 

 

 

 

 

 

 

 

 

 

G

 

841

 

 

+15V Tach Supply

Each power source requires a work lead from the

 

H

 

844

 

 

Tach common

work stud to the welding fixture. Do not combine all of

 

I

 

 

Open

 

Reserved for future use

the work leads into one lead. The welding travel direc-

 

J

 

 

GND

 

Shielding drain

 

K

 

842

 

 

Tach 1A Differential Signal

tions should be in the direction moving away from the

 

 

 

 

work lead as shown below. Connect all of the work

 

L

 

843

 

 

Tach 1B Differential Signal

 

M

 

846

 

 

Tach 2B Differential Signal

sense leads from each power source to the work

 

 

 

 

piece at the end of the weld. (See Figure A.2)

 

N

 

67

 

 

Electrode Sense (67)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

For the best results when pulse welding, set the wire

 

VOLTAGE SENSE RECEPTACLE

size and wire feed speed the same for all the Power

 

PIN

 

 

LEAD#

 

FUNCTION

 

3

 

 

21

 

 

Work Voltage Sense

Waves. When these parameters are identical, the

 

 

 

 

 

pulsing frequency will be the same, helping to stabilize

 

1

 

 

67

 

 

Electrode Voltage Sense

the arcs.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RS232 RECEPTACLE

 

Every welding gun requires a separate shielding gas

 

PIN

 

 

LEAD#

FUNCTION

regulator for proper flow rate and shielding gas cover-

 

2

 

 

253

 

 

RS232 Receive

 

3

 

 

254

 

 

RS232 Transmit

age.

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

#

 

 

Pin5

 

Do not attempt to supply shielding gas for two or more

 

5

 

 

#

 

 

Pin4

 

guns from only one regulator.

 

 

 

6

 

 

# #

 

 

Pin20

 

 

 

 

20

 

 

# #

 

 

Pin6

 

 

 

 

 

 

 

 

 

 

 

 

If an anti-spatter system is in use then each gun must

 

7

 

 

251

 

 

RS232 Common

 

 

 

 

 

 

 

 

 

have its own anti-spatter system.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WIRE FEEDER RECEPTACLE*

 

 

 

 

 

 

PIN

 

 

LEAD#

 

FUNCTION

 

 

 

 

 

 

A

 

 

153

 

 

Communiction Bus L

 

 

 

 

 

 

B

 

 

154

 

 

Communiction Bus H

 

 

 

 

 

 

C

 

 

67

 

 

Electrode Voltage Sense

 

 

 

 

 

 

D

 

 

52

 

 

Ovdc

-

 

 

 

 

 

 

E

 

 

51

 

 

+40vdc

+

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FIGURE A.2

 

POWER WAVE F355i

POWER WAVE F355i

TWO POWER WAVES

*Not on Codes 10997 or below.

Travel

Direction

Connect All Wo

Sense Leads at

End of the Join

Connect All Welding

Work Leads at the

Beginning of the Joint

POWER WAVE F355i (CE)

Image 15
Contents Power Wave F355i CE California Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding Sparks can cause fire or explosionPrécautions DE Sûreté Electromagnetic Compatibility EMC Safety Vii Please Examine Carton and Equipment For Damage ImmediatelyOn-Line Product Registration Table of Contents Power Wave F355i CE InstallationSelect Suitable Location Safety PrecautionsOutput CABLES, Connections and Limitations Negative Electrode PolarityVoltage Sensing Table A.1 Power Wave / Power Feed Wire Feeder InterconnectionsControl Cable Specifications High Speed Gear BOXDIP Switch Settings and Locations Control Board DIP SwitchFeed Head Board DIP Switch RS232 Receptacle Wire Feeder ReceptacleVoltage Sense Receptacle PIN LEAD# FunctionOperation Recommended ProcessesRequired Equipment Duty Cycle and Time Period Connector Status Lights Per Fig B.1Power Wave F355i CE LimitationsNominal Procedures Fringe ProceduresMaking a Weld Current Constant Voltage WeldingPulse Welding PULSE-ON-PULSE GMAW-PPRecommended Welding Procedures for Power Mode Table B.1 Power ModeCompatible Lincoln Equipment 1ACCESSORIESC-1Factory Installed Field InstalledExploding Parts can cause injury MaintenanceCapacitor Discharge Procedure Always wear a face shield and long sleeves when servicingHOW to USE Troubleshooting Guide TroubleshootingUsing the Status LED to Error Code # Indication Error Codes for the Power WaveTroubleshooting Guide Authorized Field Service FacilityContact your local Lincoln Problems Voltage setting. In the MIG/MAG Your local Lincoln Authorized Field Service FacilityF355i CE PowerWave F355i CE PowerConnection Diagram Dimension Print Power Wave F355i CE Precaucion Warnung