The following is a list of possible error codes that the POWER WAVE F355i (CE) can output via the status light (see "Troubleshooting the Power Wave / Power Feed System Using the Status LED." If connected to a PF-10/11 these error codes will generally be accompanied by an "Err 006" or "Err 100" on the user interface display.

 

 

 

Error Code #

Indication

 

11

CAN communication bus off.

Probably due to excessive number of communication errors.

 

12

User Interface time out error.

UI is no longer responding to the Power Source. The most likely

 

 

 

 

 

 

 

cause is a fault/bad connection in the communication leads or con-

 

 

 

 

trol cable.

 

 

 

 

 

 

 

 

 

 

21

Unprogrammed Weld Mode.

Contact the Service Department for instructions on reloading the

 

 

 

 

Welding Software.

 

 

22

Empty Weld Table.

Contact the Service Department for instructions on reloading the

 

 

 

 

Welding Software.

 

23

Weld Table checksum error.

Contact the Service Department for instructions on reloading the

 

 

 

 

 

Welding Software.

 

31

Primary overcurrent error.

Excessive Primary current present. May be related to a short in the

 

 

 

 

 

 

main transformer or output rectifier.

 

32

Capacitor "A" under voltage

Low voltage on the main capacitors. May be caused by improper

 

 

 

 

input configuration.

 

33

Capacitor "B" under voltage

When accompanied by an overvoltage error on the same side, it

 

 

 

 

indicates no capacitor voltage present on that side, and is usually

 

 

 

 

the result of an open or short in the primary side of the machine.

 

34

Capacitor "A" over voltage

Excess voltage on the main capacitors. May be caused by improp-

 

 

 

 

 

 

 

er input configuration.

 

35

Capacitor "B" over voltage

When accompanied by an under voltage error on the same side, it

 

indicates no capacitor voltage present on that side, and is usually

 

 

 

 

 

 

 

 

the result of an open or short in the primary side of the machine.

 

 

 

 

 

 

36

Thermal error

Indicates over temperature. Usually accompanied by Thermal LED.

 

Check fan operation. Be sure process does not exceed duty cycle

 

 

 

 

 

 

 

 

limit of the machine.

 

 

 

 

 

37

Soft start error

Capacitor precharge failed. Usually accompanied by codes 32-35.

 

41

Secondary overcurrent error

The secondary (weld) current limit has been exceeded. When this

 

occurs the machine output will phase back to 100 amps, typically

 

 

 

 

 

 

 

 

resulting in a condition referred to as "noodle welding"

 

 

 

 

NOTE: The secondary limit is 570 amps for the standard stud, and

 

 

 

 

325 amps for all single phase operation.

 

 

 

 

 

 

43

Capacitor delta error

The maximum voltage difference between the main capacitors has

 

been exceeded. May be accompanied by errors 32-35.

 

 

 

 

 

 

 

 

 

 

 

Other

 

Error codes that contain three or four digits are defined as fatal

 

 

 

errors. These codes generally indicate internal errors on the

 

 

 

 

 

 

 

 

Control Board. If cycling the input power on the machine does not

 

 

 

 

clear the error, try reloading the operating system. If this fails,

 

 

 

 

replace the control board.

 

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

POWER WAVE F355i (CE)

Image 25
Contents Power Wave F355i CE California Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding Sparks can cause fire or explosionPrécautions DE Sûreté Electromagnetic Compatibility EMC Safety Please Examine Carton and Equipment For Damage Immediately ViiOn-Line Product Registration Table of Contents Power Wave F355i CE InstallationSelect Suitable Location Safety PrecautionsNegative Electrode Polarity Output CABLES, Connections and LimitationsVoltage Sensing Control Cable Specifications Power Wave / Power Feed Wire Feeder InterconnectionsHigh Speed Gear BOX Table A.1Control Board DIP Switch DIP Switch Settings and LocationsFeed Head Board DIP Switch Voltage Sense Receptacle Wire Feeder ReceptaclePIN LEAD# Function RS232 ReceptacleRecommended Processes OperationRequired Equipment Power Wave F355i CE Connector Status Lights Per Fig B.1Limitations Duty Cycle and Time PeriodFringe Procedures Nominal ProceduresMaking a Weld Pulse Welding Constant Voltage WeldingPULSE-ON-PULSE GMAW-PP CurrentRecommended Welding Procedures for Power Mode Table B.1 Power ModeFactory Installed 1ACCESSORIESC-1Field Installed Compatible Lincoln EquipmentCapacitor Discharge Procedure MaintenanceAlways wear a face shield and long sleeves when servicing Exploding Parts can cause injuryHOW to USE Troubleshooting Guide TroubleshootingUsing the Status LED to Error Code # Indication Error Codes for the Power WaveAuthorized Field Service Facility Troubleshooting GuideContact your local Lincoln Problems Voltage setting. In the MIG/MAG Your local Lincoln Authorized Field Service FacilityF355i CE PowerWave F355i CE PowerConnection Diagram Dimension Print Power Wave F355i CE Precaucion Warnung