Friedrich SP08A10, SP06A10 Disassembly and Reassembly ProcedureSP10A10/SP12A10, Ass’y Grille

Page 12

4-3.Disassembly and Reassembly Procedure(SP10A10/SP12A10)

Stop operating the air conditioner, and pull out the power cord before repair.

No.

Part Name

Procedures

Remarks

 

 

 

 

 

1

Ass’y Grille

1.Pull the Grille air inlet and Guard air filter out.

 

 

 

 

2.Remove the screw on the panel front.

 

 

 

 

3.Hold the lower part of panel with two hands

 

 

 

 

while pressing down on both sides of the lower

 

 

 

 

part of the cabinet, pull it forward by about

 

 

 

 

30mm,and then lift it up carefully for

 

 

 

 

removal.(Must un-connect the Displayer with

 

 

 

 

the controller inside.)

 

 

 

 

 

 

 

2

Ass’y Cabinet

1.Remove 2 screws on the both side of the

 

 

 

 

cabinet.

 

 

 

 

2.Pull the front part both side, and remove the

 

 

 

 

unit from the cabinet.

 

 

 

 

 

 

 

3

Ass’y Control

1.Remove the earth screw fixed on the cabinet.

 

 

 

 

2.Remove 3 screws fixed on the partition and

 

 

 

 

frame up.

 

 

 

 

3.Remove the screw fixed for the power cord.

 

 

 

 

4.Un-connect the motor wire and comp lead

 

 

 

 

wire, then take out the control box upward.

 

 

 

 

 

 

 

 

 

 

FRIEDRICH AIR CONDITIONING CO.

4-3

Image 12
Contents Room AIR Conditioner Precautions Avoid Dangerous ContactFriedrich AIR Conditioning CO Memo Dimensions Installation and Operating Instructions InstallationSelecting Area for Installation Cooling operation mode Fan operation modeEnergy saver operation mode Function DescriptionSleep operation mode Dry operation modeLED display indication in case of error detection Memo Disassembly and Reassembly Compressor Replacement Flow ChartChecking the oil Oil qualityReplacing and refilling the refrigerant oil Disassembly and Reassembly ProcedureSP10A10/SP12A10 Ass’y GrillePart Name Procedures Remarks Disassembly and Reassembly ProcedureSP06A10/SP08A10 Friedrich AIR Conditioning Troubleshooting Basic Checkpoints for TroubleshootingTroubleshooting by Symptom No powerWhen the Touch Key pad and Led Display TroubleshootingWhen the remocon is not operated When the compressor is not operated When the fan motor does not operated LOWExploded View and Parts List Main unitExploded View and Parts List Part List Exploded view and part list Friedrich AIR Conditioning CO Block Diagram Refrigerating Cycle Block DiagramMicom Control Diagram Basic StructureMicom pin assignment KS88C4716 RemoconMemo PCB Diagram Part List Part List Wiring Diagram Schematic Diagrams 10-1 PCB Friedrich AIR Conditioning CO