Friedrich SP12A10, SP10A10, SP08A10 When the Touch Key pad and Led Display, Troubleshooting

Page 18

5-2-2 When the Touch Key pad and Led Display

1)Check points

(1)Is the voltage of the power source normal ? (the rating voltage ±10% range.)

(2)Is the electric wire in good contact ?(CN71, RY71)

(3)Is the connection of the assembly main PCB, and TOUCH KEY PAD in good contact? (SW01-SW05)

Turn off the power, and then turn it on again

five seconds later.

Troubleshooting

Normal operation

Check the micom (IC05) for a short, and replace it.

N

 

When the LED display is

When the membrane key is

 

N

 

 

 

not operated.

not operated.

 

 

 

 

 

 

Y

 

Y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N

 

Is the voltage of the micom

Is the voltage of the

 

N

 

 

 

(IC05) No.1, 2, 38~43 port a

micom (IC05) No.13, 14 port

 

 

 

 

 

 

 

 

 

square wave?

a square wave?

 

 

 

Normal operation

Check the micom (IC05) for a short, and replace it.

 

 

 

 

Y

 

Y

 

 

 

 

 

 

Is the voltage of the micom

 

Check the micom

 

N

Is the voltage of the micom

N

(IC05) for a short,

 

 

(IC05) No.3, 4, 10, 11, 44 port

(IC05) No.3, 4, 10, 11, 44

 

 

 

 

and replace it.

 

 

a square wave?

port a square wave?

 

 

 

 

 

 

 

 

 

Check the micom (IC05) for a short, and replace it.

Check the Q901~ Q905 for a short, and replace it.

Check the IC06 for a short, and replace it.

Y

NIs the voltage of the

Q901 ~ Q905 square wave?

Y

NIs the voltage of the

IC06 No. 10~16 a square

value?

Y

Replace the membrane

key pad.

Y

Replace the membrane key pad

FRIEDRICH AIR CONDITIONING CO.

5-3

Image 18
Contents Room AIR Conditioner Precautions Avoid Dangerous ContactFriedrich AIR Conditioning CO Memo Dimensions Installation and Operating Instructions InstallationSelecting Area for Installation Energy saver operation mode Cooling operation modeFan operation mode Function DescriptionSleep operation mode Dry operation modeLED display indication in case of error detection Memo Disassembly and Reassembly Compressor Replacement Flow ChartChecking the oil Oil qualityReplacing and refilling the refrigerant oil Disassembly and Reassembly ProcedureSP10A10/SP12A10 Ass’y GrillePart Name Procedures Remarks Disassembly and Reassembly ProcedureSP06A10/SP08A10 Friedrich AIR Conditioning Troubleshooting Basic Checkpoints for TroubleshootingTroubleshooting by Symptom No powerWhen the Touch Key pad and Led Display TroubleshootingWhen the remocon is not operated When the compressor is not operated When the fan motor does not operated LOWExploded View and Parts List Main unitExploded View and Parts List Part List Exploded view and part list Friedrich AIR Conditioning CO Micom Control Diagram Block DiagramRefrigerating Cycle Block Diagram Basic StructureMicom pin assignment KS88C4716 RemoconMemo PCB Diagram Part List Part List Wiring Diagram Schematic Diagrams 10-1 PCB Friedrich AIR Conditioning CO