Friedrich SP10A10, SP08A10, SP12A10, SP06A10 service manual Sleep operation mode, Dry operation mode

Page 8

Installation and Operating Instructions

3-2-4 Sleep operation mode

1)Enable to sleep operation only when cooling operation.

2)First, 7-SEG LED DISPLAY "SLEEP" while 15 second, Second, 7-SEG LED DISPLAY "8Hr" And, automatically SET OFF after operated while 8 Hour

3)If sleep operation, setting Temperature rise 1˚C after 1 Hour

4)ON TIMER operation, not operation, ENERGY SAVER operation, not sleep operation.

3-2-5 Dry operation mode

If the atmosphere in the room is very humid or damp,use this operation mode. It can remove excess humidity without lowering the room temperature too much.

1) The quantity of air is adjusted automatically.

3-2-6 LED display indication in case of error detection

ERROR OPERATION

7-SEG

LED DISPLAY

 

ROOM THERMISTOR

E1 displayed

(OPEN or SHORT)

 

1)Set operation in case of error occurrence.

Malfunction of each temperature sensor (open, short)

-Error mode display, warning sound.

-The operation status is off.

FRIEDRICH AIR CONDITIONING CO.

3-3

Image 8
Contents Room AIR Conditioner Precautions Avoid Dangerous ContactFriedrich AIR Conditioning CO Memo Dimensions Selecting Area for Installation Installation and Operating InstructionsInstallation Cooling operation mode Fan operation modeEnergy saver operation mode Function DescriptionLED display indication in case of error detection Sleep operation modeDry operation mode Memo Disassembly and Reassembly Compressor Replacement Flow ChartReplacing and refilling the refrigerant oil Checking the oilOil quality Disassembly and Reassembly ProcedureSP10A10/SP12A10 Ass’y GrillePart Name Procedures Remarks Disassembly and Reassembly ProcedureSP06A10/SP08A10 Friedrich AIR Conditioning Troubleshooting Basic Checkpoints for TroubleshootingTroubleshooting by Symptom No powerWhen the Touch Key pad and Led Display TroubleshootingWhen the remocon is not operated When the compressor is not operated When the fan motor does not operated LOWExploded View and Parts List Main unitExploded View and Parts List Part List Exploded view and part list Friedrich AIR Conditioning CO Block Diagram Refrigerating Cycle Block DiagramMicom Control Diagram Basic StructureMicom pin assignment KS88C4716 RemoconMemo PCB Diagram Part List Part List Wiring Diagram Schematic Diagrams 10-1 PCB Friedrich AIR Conditioning CO