Friedrich SP06A10, SP10A10, SP08A10, SP12A10 service manual Friedrich AIR Conditioning CO

Page 3

2.Product Specifications

2-1 Table

Item

Unit of

SP06A10

SP08A10

 

SP10A10

SP12A10

Measure

 

 

 

 

 

 

 

 

 

 

 

 

 

Type

 

 

WINDOW

 

Dimension:

mm

520×345×485

 

600×394×595

(Width×Height×Depth)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Voltage

Volt

 

115

 

 

Phase

-

 

SINGLE

 

Frequency

Hz

 

60

 

 

Operation Current

A

5.4

6.6

 

9.3

10.5

Power Consumption

W

610

740

 

1000

1170

Refrigerant Type

FREON

 

R22

 

Refrigerant Change

g

300

470

 

450

635

Capacity

BTU/h

6500

8000

 

10800

12600

EER

BTU/h.W

10.8

10.8

 

10.8

10.8

Net Weight

Kg

26

29

 

43

45

Condenser

Row

2×15

3×15

 

2×17

3×17

Condenser Fan

Type

 

Propeller Fan

 

Evaporator

Row

2×11

2×11

 

2×12

2×10

Evaporator Fan

Type

 

Blower

 

Fan Motor

MODEL

YSLA-40-6-0002

YSLA-40-6-0003

 

YGN60-6B

YGN60-6B

Compressor(Rotary)

MODEL

39A062HS1EA

44A076HU1EB

 

44B098HX1EF

44B117HX1EL

Overload Protect

-

MRA12146-120

MRA12083-120

 

MRA12132-12007

MRA12053-12007

08

08

 

 

 

 

 

 

 

 

 

 

 

 

 

Compressor Capacitor

μF/VAC

40/370

35/370

 

45/370

50/370

 

 

 

 

 

 

 

Fan Motor Capacitor

μF/VAC

8/450

8/450

 

15/250

15/250

Fan Speed

RPM

920/850/800

1050/1010/970

 

890/850/800

890/860/750

Thermo Control

-

 

THERMISTOR

 

FRIEDRICH AIR CONDITIONING CO.

2-1

Image 3
Contents Room AIR Conditioner Avoid Dangerous Contact PrecautionsFriedrich AIR Conditioning CO Memo Dimensions Installation and Operating Instructions InstallationSelecting Area for Installation Function Description Cooling operation modeFan operation mode Energy saver operation modeSleep operation mode Dry operation modeLED display indication in case of error detection Memo Compressor Replacement Flow Chart Disassembly and ReassemblyChecking the oil Oil qualityReplacing and refilling the refrigerant oil Ass’y Grille Disassembly and Reassembly ProcedureSP10A10/SP12A10Part Name Procedures Remarks Disassembly and Reassembly ProcedureSP06A10/SP08A10 Friedrich AIR Conditioning Basic Checkpoints for Troubleshooting TroubleshootingNo power Troubleshooting by SymptomTroubleshooting When the Touch Key pad and Led DisplayWhen the remocon is not operated When the compressor is not operated LOW When the fan motor does not operatedMain unit Exploded View and Parts ListExploded View and Parts List Part List Exploded view and part list Friedrich AIR Conditioning CO Basic Structure Block DiagramRefrigerating Cycle Block Diagram Micom Control DiagramRemocon Micom pin assignment KS88C4716Memo PCB Diagram Part List Part List Wiring Diagram Schematic Diagrams 10-1 PCB Friedrich AIR Conditioning CO