Friedrich SQ05, SQ10, SQ06 Final Inspection & Start-up Checklist, This is a warm weather appliance

Page 30

Final Inspection & Start-up Checklist

‹Inspect and ensure that all components and accessories have been installed properly and that they have not been damaged during the installation progress.

‹Check the condensate water drain(s) to ensure that they are adequate for the removal of condensate water, and that they meet the approval of the end user.

‹Ensure that all installation instructions concerning clearances around the unit have been adhered to. Check to ensure that the unit air filter, indoor coil, and outdoor coil are free from any obstructions.

‹Ensure that the circuit breaker(s) or fuse(s) and supply circuit wire size have been sized correctly. If the unit was supplied with a power supply cord, insure that it is stored properly.

‹Ensure that the entire installation is in compliance with all applicable national and local codes and ordinances having jurisdiction.

‹Secure components and accessories, such as a decorative front cover.

‹Start the unit and check for proper operation of all components in each mode of operation.

‹Instruct the owner or operator of the units operation, and the manufacturer's Routine Maintenance.

NOTE: A log for recording the dates of maintenance and/or service is recommended.

‹Present the owner or operator of the equipment with the Installation & Operation Manual, all accessory installation instructions, and the name, address and telephone number of the Authorized Friedrich Warranty Service Company in the area for future reference if necessary.

This is a warm weather appliance

Your air conditioner is designed to cool in warm weather when the outside temperature is above 60°F (15.6°C) and below 115°F (46.1°C), so it won't cool a room if it is already cool outside.

Condensation is normal

Air conditioners actually pump the heat and humidity from your room to the outside. Humidity becomes water, and your air conditioner will use most of the water to keep the outside coil cool. If there is excessive humidity, there may be excess water that will drip outside. This is normal operation.

Frosting

This usually occurs because of insufficient airflow across the coils, a dirty filter, cool damp weather, or all of these. Set the SYSTEM mode to FAN ONLY and the frost will disappear. Setting the thermostat a little warmer will probably prevent the frosting from recurring.

Noises

All air conditioners make some noise. Friedrich units are designed to operate as quietly as possible. An air conditioner mounted in a wall is quieter than one mounted in a window. It is important to ensure that the chassis seal gasket (Item 14) is properly installed (refer to installation instructions).

30

Image 30
Contents Room Air Conditioners Register your air conditioner Table of Contents Safety Precautions Your safety and the safety of others are very importantUnpacking Instructions Make sure the wiring is adequate for your unit Standard Filter Cleaning / Installation Instructions Premium Carbon Filter Installation InstructionsFAN only FAN Mode Control Panel OperationKühl Control Options FAN only Mode Control Panel Operation Instructions11 AM ºF ºC Select Alerts Advanced Functions Onam Timer Scheduler Control Block Timer on Scenarios Timer OFF Scenarios Remote Control Operation Remote EffectivenessAuto FAN Continuous AirÁow Selection and Adjustment Installation InstructionsRecommended tools required for installation not included Standard Window Installation Falling Object HazardSection A-A Excessive Weight Hazard Cord Routing Change Factory Setting with LEFT-SIDE Thru-the-wall Installation Concrete Block ConstructionSolid Masonry Construction Final Inspection & Start-up Checklist This is a warm weather applianceRoutine Maintenance Service and AssistanceAvailable Accessories Troubleshooting Tips Complaint Cause SolutionComplaint Cause Solution Addendum Schedule Table with Energy Saving ValuesRoom AIR Conditioners Limited Warranty 9300100301 Unidades de Aire Acondicionado Registre su aíre acondicionado Índice Medidas de Seguridad Advertencia PrecauciónInstrucciones de Desempaquetado Aviso Limpieza del Filtro Estándar / Instrucciones de Instalación Instrucciones de Instalación del Filtro de Carbono PremiumFuncionamiento del Panel de Control Solo VentiladorNuevas Opciones de Control Kühl Instrucciones de Funcionamiento del Panel de Control Modo FríoTimer Mode System FAN Mode Speed System FAN Mode System FAN Mode Speed FAN Speed Escenarios de Temporizador en Encendido Escenarios del Temporizador en Apagado Funcionamiento del Control Remoto Auto Instrucciones de Instalación Selección y Ajuste del Flujo de AireHerramientas recomendadas para la instalación no incluidas Instalación de Ventana Estándar AdvertenciaSección A-A FRR088 Cambio de Enrutamiento del Cable Desconecte la unidadAcercamiento Instalación a Través de la Pared PrecaucionConstrucción DE Mampostería Sólida Inspección Final & Lista de Verificación de Arranque Es un aparato de clima cálidoMantenimiento de Rutina Servicio y AsistenciaAccesorios Disponibles Consejos Para Solucionar Problemas Queja Causa SoluciónCausa Solución Queja Anexo Cuadro de Programación con Valores de Ahorro de EnergíaUnidades DE Aire Acondicionado Garantía Limitada Primer AÑO 9300100301 Climatiseurs Enregistrer votre climatiseur Table des matières Précautions de sécurité Instructions de Déballage Avertissement Nettoyage et installation du filtre standard Opération du Panneau de Contrôle Nouvelles Options de Contrôle Kühl Instructions d’Opération du Panneau de Contrôle Autres Fonctions Mode FAN 79 F Fonctions Avancees Heure d’arrêt du Minuteur Verrouillage du Minuteur-Horaire Minuteur en Marche System FAN Mode Speed Timer Opération de la télécommande Système Température Hausse Vitesse Ventilateur Affichage Instructions d’installation Outils recommand és pour l’installation non inclus Installation dans Fenêtre Standard Avertissement Atention Changement de routage du cordon Arrangement Avec Cordon Installation dans un mur Construction DE Maçonnerie ’appareil est conçu pour les climats chauds Entretien Régulier Guide de Dépannage Probleme Cause Solution Addenda Climatiseurs Garantie Limitée 9300100301
Related manuals
Manual 36 pages 27.03 Kb

SQ08, SQ05, SQ06, SQ10 specifications

Friedrich is a renowned name in the HVAC industry, known for its innovative solutions in cooling and heating technologies. Among its impressive lineup, the SQ series, consisting of models SQ10, SQ06, SQ05, and SQ08, stands out for their robust features and advanced performance.

One of the defining characteristics of the SQ series is its energy efficiency. Each model is designed to optimize energy use, allowing for significant cost savings while reducing the environmental impact. This is primarily achieved through the incorporation of advanced inverter technology, which adjusts the compressor speed according to cooling or heating demand, maintaining a comfortable indoor climate without excessive energy consumption.

The SQ series units are equipped with high-performing compressors that provide rapid cooling and heating capabilities. This means that users can expect fast temperature adjustments, ensuring a comfortable environment even during extreme weather conditions. Moreover, the noise levels of these units have been engineered to remain low, offering whisper-quiet operation that does not disrupt daily activities.

Control and convenience are also paramount in the SQ series. The units feature smart technologies that allow for remote operation through mobile applications. This means homeowners can adjust temperatures, set schedules, and monitor their energy usage from anywhere, adding a layer of convenience to the user experience. The user-friendly interface and intuitive controls further enhance accessibility.

Durability and reliability are core elements of the SQ models. Constructed with high-quality materials and components, these units are built to withstand the rigors of daily use. The units also come with comprehensive warranties, offering peace of mind to users regarding long-term performance.

In summary, Friedrich's SQ10, SQ06, SQ05, and SQ08 units showcase a blend of energy efficiency, advanced technology, and user-centric features. With their quiet operation, fast temperature adjustments, and smart connectivity, they provide an ideal solution for reliable heating and cooling needs in residential or commercial spaces. The robust design ensures longevity, making Friedrich a trusted choice in climate control solutions.