Lincoln Electric 275 manual General Options Accessories, TIG Welding Options Accessories

Page 27

C-1

ACCESSORIES

C-1

 

 

 

GENERAL OPTIONS /

ACCESSORIES

The following options/accessories are available for your Ranger 275:

K886-1 Canvas Cover - To protect the Ranger 275 when it is not being operated. Made from attractive red canvas material that is flame retardant, mildew resistant and water repellent.

K889-2 Two Wheel Undercarriage - For moving by hand. Two 4.00" x 8" pneumatic tires. Overall width 29" (.74m).

K893-1 Caster for K889-2 Undercarriage - Mounts to the front of the Two-Wheel undercarriage to allow easy movement on smooth surfaces. Includes a 6" diameter hard rubber wheel with a convenient toe-on,toe-off locking brake.

K933-1 Four Wheel Undercarriage - Allows move- ment of the Ranger 275 by hand without lifting on smooth surfaces. Includes two rugged, hard molded wheels and two durable pneumatic tires. The spring loaded handle provides convenient, comfortable steer- ing. The K934-1 Bracket is available for mounting a gas cylinder on the undercarriage.

K934-1 Bracket for Mounting a Gas Cylinder to a K933-1 Undercarriage - Easily mounts on the back of the K933-1 Four Wheel Undercarriage to carry a weld- ing gas cylinder.

K957-1 Two-Wheeled Trailer - For in-plant or yard towing of the Ranger 275. Suitable for road towing with optional Fender and Light Kit. The following options are available for the K957-1Two-Wheeled Trailer:

K958-1 - Ball Coupler 2"

K958-2 - Lunette Eye Coupler

K959-2 - Fender & Light

K965-1 - Cable Rack

K894-1 Spark Arrester Kit - A field installed kit for the Ranger 275 engine muffler exhaust pipe. Includes a heavy-gauge steel, approved spark arrester, mount- ing clamp and adapter.

K703 Accessory Kit - Includes the following:

- Thirty-five feet (10.5 meters) of # 1/0 AWG elec- trode cable.

-Thirty feet (9.1 meters) of # 1/0 AWG work cable.

-Headshield with No. 12 filter.

-GC500 work clamp.

-Cooltong® 300 insulated electrode holder.

K802-R Power Plug Kit - Provides four 15 amp, 120 volt plugs and one 50 amp, dual voltage 120/240V, full kVA plug.

K857 Remote Control - Includes a control box with 25 feet (7.5 meters) of 4-conductor cable. Allows out- put voltage to be controlled remotely.

K857-1 Remote Control - Includes a control box with 100 feet (30.5 meters) of 4-conductor cable. Allows output voltage to be controlled remotely.

K896-1 GFCI Receptacle Kit - Includes two UL approved 120 volt ground fault circuit interrupter receptacles (duplex type) with covers and installation instructions. Each receptacle is rated 15 amps, but the maximum total current from each GFCI duplex is limited to 20 amps. The GFCI receptacles replace the two factory installed 120 volt duplex receptacles.

TIG WELDING OPTIONS /

ACCESSORIES

K930-2 TIG Module - The TIG Module is an accesso- ry that provides high frequency and shielding gas con- trol for AC and DC GTAW (TIG) welding applications. It provides contactor control of constant current weld- ing power sources having an internal contactor. The TIG Module is supplied without accessories, Arc Start switches, Amptrols, cables, torches and mounting brackets must be purchased separately.

K939-1 Docking Kit - For mounting the K930-1 TIG Module on top of the Ranger 275.

K936-1 Control Cable - Control cable for connecting the K930-2 TIG Module to a Ranger 275.

K814 Arc Start Switch - A remote start switch used in conjunction with the K930-2 TIG Module to energize the Ranger 275 output terminals via the TIG module.

K963 Hand Amptrol - Remote output control and contactor control.

K870 Foot Amptrol - Remote output control and con- tactor control.

RANGER 275

Image 27
Contents Ranger Safety Electric Shock can kill Cylinder may explode if damaged Précautions DE Sûreté Thank You Table of Contents Vii Installation Technical Specifications Ranger 275 K1641-1 Installation Instructions PRE-OPERATION Engine Service Fuel Electrical Connections Auxiliary Power RECEPTACLES, PLUGS, and HAND-HELD Equipment Figure A.1 Operating Instructions Safety InstructionsDesign Features OperationAdditional Safety Precautions Recommended ApplicationsLimitations Figure B.1 Output Panel Controls WELDER/GENERATOR Controls Controls and SettingsEngine Operation Before Starting the EngineStarting the Engine Table B.1 Stopping the EngineLocal Welding OperationWelder Controls Function and Operation ARC ControlStick Welding Pipe WeldingTIG Welding Table B.2 Typical Current Ranges 1 for Tungsten ELECTRODES2 Wire WeldingUsed Switch Table B.3 Summary of Welding Processes and Machine SettingsAuxiliary Power Simultaneous Welding and Power LoadsTable B.4 Accessories General Options AccessoriesTIG Welding Options Accessories Semiautomatic Fcaw and MIG Welding Options / Accessories Accessories Connection Diagrams PIN Amphenol Amphenol Ranger 275 to K867 Control Cable Adapter Connection Diagram Ranger 275 / K930 TIG Module / Connection Diagram Engine Maintenance Parts Table D.1 MaintenanceSafety Precautions Routine and Periodic Engine MaintenanceTable D.2 Kohler Engine Maintenance Schedule Table D.3 Engine OIL Refill Capacities AIR Cleaner ServiceChanging the Engine OIL Table D.4 OIL Filter Tigntening TorquesTable D.6 Spark Plug Installation Specifications Spark Plug ServiceFuel Filter Service Engine AdjustmentsBattery Maintenance Servicing Optional Spark Arrestor Welder / Generator MaintenanceCleaning Brush Removal and ReplacementHOW to USE Troubleshooting Guide 1TROUBLESHOOTINGE-1Troubleshooting Field Service Facility for technical No welding power output Contactor switch in wrong posi Wiring Diagram DiagramsDimension Print Ranger How To Read Shop Drawings Precaucion Warnung
Related manuals