Lincoln Electric Installation, Technical Specifications Flextec 450 CE, Voltage, Conductor

Page 8

 

A-1

 

 

 

 

 

INSTALLATION

 

 

A-1

 

TECHNICAL SPECIFICATIONS - FLEXTEC™ 450 CE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POWER SOURCE-INPUT VOLTAGE AND CURRENT

 

 

 

Model

 

 

 

Duty Cycle

Input Voltage ± 10%

Input Amperes

 

Idle Power

Power Factor @

 

 

 

 

 

 

 

 

 

 

 

 

 

Rated Output

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60% rating

 

37 / 35 / 34

 

72 Watts

 

 

 

K3065-1

 

 

 

 

 

380 / 400 / 415 / 3 / 50 / 60

 

 

 

Max.

95%

 

 

 

 

 

100% rating

 

 

 

 

 

 

 

 

29 / 28 / 27

 

 

 

 

 

 

 

 

 

(fan on)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RATED OUTPUT

 

 

 

 

 

Process

 

 

 

Duty Cycle

Volts at Rated Amperes

 

 

Amperes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60%

36.5V

 

 

 

450

 

 

 

GMAW (CV)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100%

34V

 

 

 

400

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60%

28V

 

 

 

450

 

 

 

GTAW (CC)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100%

26V

 

 

 

400

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60%

38V

 

 

 

450

 

 

 

MMAW (CC)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100%

36V

 

 

 

400

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60%

36.5V

 

 

 

450

 

 

 

FCAW-GS (CV)

 

 

 

 

 

 

 

 

 

 

 

 

 

100%

34V

 

 

 

400

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60%

36.5V

 

 

 

450

 

 

 

FCAW-SS (CV)

 

 

 

 

 

 

 

 

 

 

 

100%

34V

 

 

 

400

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RECOMMENDED INPUT WIRE AND FUSE SIzES (1)

 

 

 

VOLTAGE

Maximum

 

4 CONDUCTOR

 

Fuse (Super Lag) or

 

 

50/60Hz

 

Input

 

SOOW or similar Cord in 40°C(104°F) Ambient

 

breaker Size (2)

 

 

 

Amperes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

380/3/50

 

42 A

 

 

 

 

 

 

 

 

 

 

400/3/60

 

40 A

 

8 AWG or 10mm2

 

 

50

 

 

415/3/60

 

39 A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(1)Cord and Fuse Sizes based upon the U.S. National Electric Code and maximum output for 40°C (104°) ambient.

(2)Also called “inverse time” or “thermal/magnetic” circuit breakers; circuit breakers that have a delay in tripping action that decreases as the magnitude of current increases.

FLEXTEC™ 450 CE

Image 8
Contents Safety Depends on You Flextec 450 CESafety California Proposition 65 WarningsElectric Shock can kill Welding and Cutting Sparks can Cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a L’ArcPlease Examine Carton and Equipment For Damage Immediately On-Line Product RegistrationTAbLE of Contents Installation Technical Specifications Flextec 450 CEVoltage ConductorModel Height Width Depth Weight Operating Temperature Range Storage Temperature RangeProcess Output Range Amperes OCV Uo OCV UrSafety Precautions StackingEnvironmental Limitations VRD Voltage Reduction DeviceInput Fuse and Supply Wire Considerations Input ConnectionPIN Remote Control Connector Function Pin WiringPIN Connector for Wire Feeder CAbLE ConnectionsRecommended Electrode and Work CAbLE SIzES for ARC Welding Control CAbLE ConnectionsGeneral Guidelines TAbLE A.1 Output CAbLE GuidelinesOperation Safety PrecautionsInput Power OFF High Temperature Design Features Product DescriptionProtective GroundRecommended Processes Equipment Equipment LimitationsRecommended Processes Process LimitationsCase Front Control Descriptions Figure b.1Common Welding Procedures POWER-UP SequenceCase bACK Control Weld Controls and DisplaysVRD Voltage Reduction Device Indicator Light VRD Indicator LightsBASIC Modes of Operation MmawGtaw Weld Terminals On/RemoteCV-GAS CV-INNERSHIELDAccessories Options / AccessoriesGeneral Options TIG OptionsMaintenance Routine MaintenancePERIODIC MAINTENANCE Visual InspectionTROUbLESHOOTING PRObLEMS SymptomsPOSSIbLE Cause Recommended Course of ActionError Codes for the Flextec 450 CE Error Description Corrective Action Code#Diagrams Dimension Print Flextec 450 CE Precaucion Warnung