| INSTALLATION |
|
| |||||||
| TECHNICAL SPECIFICATIONS - FLEXTEC™ 450 CE |
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| POWER |
|
| ||||||
| Model |
|
|
| Duty Cycle | Input Voltage ± 10% | Input Amperes |
| Idle Power | Power Factor @ |
| ||||
|
|
|
|
|
|
|
|
|
|
|
| Rated Output |
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
| 60% rating |
| 37 / 35 / 34 |
| 72 Watts |
|
| |||
|
|
|
|
|
| 380 / 400 / 415 / 3 / 50 / 60 |
|
|
| Max. | 95% |
| |||
|
|
|
| 100% rating |
|
|
|
| |||||||
|
|
|
| 29 / 28 / 27 |
|
| |||||||||
|
|
|
|
|
|
| (fan on) |
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| RATED OUTPUT |
|
|
|
| |||
| Process |
|
|
| Duty Cycle | Volts at Rated Amperes |
|
| Amperes |
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
| 60% | 36.5V |
|
|
| 450 |
|
| ||
| GMAW (CV) |
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
| 100% | 34V |
|
|
| 400 |
|
| ||||
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
| 60% | 28V |
|
|
| 450 |
|
| ||
| GTAW (CC) |
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
| 100% | 26V |
|
|
| 400 |
|
| ||||
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
| 60% | 38V |
|
|
| 450 |
|
| ||
| MMAW (CC) |
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
| 100% | 36V |
|
|
| 400 |
|
| ||||
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
| 60% | 36.5V |
|
|
| 450 |
|
| ||
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
| 100% | 34V |
|
|
| 400 |
|
| ||||||
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
| 60% | 36.5V |
|
|
| 450 |
|
| ||
|
|
|
|
|
|
|
|
|
|
| |||||
| 100% | 34V |
|
|
| 400 |
|
| |||||||
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| RECOMMENDED INPUT WIRE AND FUSE SIzES (1) |
|
| ||||||
| VOLTAGE | Maximum |
| 4 CONDUCTOR |
| Fuse (Super Lag) or |
| ||||||||
| 50/60Hz |
| Input |
| SOOW or similar Cord in 40°C(104°F) Ambient |
| breaker Size (2) |
| |||||||
|
| Amperes |
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| 380/3/50 |
| 42 A |
|
|
|
|
|
|
|
|
| |||
| 400/3/60 |
| 40 A |
| 8 AWG or 10mm2 |
|
| 50 |
| ||||||
| 415/3/60 |
| 39 A |
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
(1)Cord and Fuse Sizes based upon the U.S. National Electric Code and maximum output for 40°C (104°) ambient.
(2)Also called “inverse time” or “thermal/magnetic” circuit breakers; circuit breakers that have a delay in tripping action that decreases as the magnitude of current increases.