INSTALLATION

A-8

CONNECTION OF LINCOLN ELECTRIC WIRE FEEDERS

Connection of LN-7 or LN-8 to the RANGER 305G

1.Shut the welder off.

2.Connect the LN-7 or LN-8 per instructions on the appropriate connection diagram in Section F

3.Set the "WIRE FEEDER VOLTMETER" switch to either "+" or "-" as required by the electrode being used.

4.Set the "MODE" switch to the "CV WIRE " posi- tion.

5.Set the "ARC CONTROL" knob to "0" initially and adjust to suit.

6 Set the "WELD TERMINALS" switch to the "REMOTELY CONTROLLED" position.

7. Set the "IDLE" switch to the "HIGH" position.

Connection of LN-15 to the RANGER 305G

These connections instructions apply to both the LN-

15Across The-Arc and Control Cable models. The LN-15 has an internal contactor and the electrode is not energized until the gun trigger is closed. When the gun trigger is closed the wire will begin to feed and the welding process is started.

Shut the welder off.

For electrode Positive, connect the electrode cable to the "+" terminal of the welder and work cable to the "-" terminal of the welder. For electrode Negative, connect the electrode cable "-" terminal of the welder and work cable to the "+" terminal of the welder.

Across The-Arc Model:

Attach the single lead from the front of the LN-15 to work using the spring clip at the end of the lead. This is a control lead to supply current to the wire feeder motor; it does not carry welding current.

Set the "WELD TERMINALS" switch to "WELD TER-

MINALS ON"

Control Cable Model:

Connect Control Cable between Engine Welder and Feeder.

Set the "WELD TERMINALS" switch to "REMOTELY CONTROLLED"

Set the MODE switch to the "CV-WIRE " position.

Set the "WIRE FEEDER VOLTMETER" switch to either "+" or "-" as required by the electrode polarity being used.

Set the "ARC CONTROL" knob to "0" initially and adjust to suit.

Set the "IDLE" switch to the "AUTO" position.

Connection of the LN-25 to the RANGER 305G

WARNING

Shut off welder before making any electrical con- nections.

------------------------------------------------------------------------

The LN-25 with or without an internal contactor may be used with the RANGER 305G. See the appropriate connection diagram in Section F.

NOTE: The LN-25 (K431) Remote Control Module and (K432) Remote Cable are not recommended for use with the RANGER 305G.

1.Shut the welder off.

2.For electrode Positive, connect the electrode cable from the LN-25 to the "+" terminal of the welder and work cable to the "-" terminal of the welder. For electrode Negative, connect the elec- trode cable from the LN-25 to the "-" terminal of the welder and work cable to the "+" terminal of the welder.

3.Attach the single lead from the front of the LN-25 to work using the spring clip at the end of the lead. This is a control lead to supply current to the wire feeder motor; it does not carry welding current.

4.Set the MODE switch to the "CV-WIRE " position.

5.Set the "WELD TERMINALS" switch to "WELD

TERMINALS ON"

6.Set the "ARC CONTROL" knob to "0" initially and adjust to suit.

RANGER 305G

Image 16
Contents Ranger Safety California Proposition 65 WarningsElectric Shock can kill Welding and Cutting Sparks can Cause fire or explosion Précautions DE Sûreté Sûreté Pour Soudage a LʼArcThank You Table of Contents Vii Installation Technical Specifications Ranger 305G K1726-4, K1726-5Machine Specifications Ranger 305G K1726-4, K1726-5 Receptacles and Circuit BreakersSafety Precautions Additional Safety PrecautionsLocation and Ventilation High Altitude OperationPRE-OPERATION Engine Service Battery Connection GasolineOIL FuelElectrical Connections Standby Power Connections Auxiliary Power ReceptaclesWelding Output Cables Total Combined Length of Electrode and Work CablesConnection of Ranger 305G to Premises Wiring Connection of Lincoln Electric Wire Feeders Connection of LN-7 or LN-8 to the Ranger 305GInstallation Operation Design FeaturesGeneral Description Weld Mode Selector Switch Welding Controls Output ControlDigital Output Meters ARC ControlPIN Connector Weld Terminals Control SwitchWire Feeder Voltmeter Switch Idler SwitchWelder Operation TIG Welding Wire WELDING-CVTypical Current Ranges 1 for Tungsten ELECTRODES2 Auxiliary Power ARC GougingAccessories Engine Maintenance Components MaintenanceKohler Engine Engine Spark Plug AIR Filter Paper ElementEngine Adjustment Battery MaintenanceFuel Filter Servicing Optional Spark ArrestorWelder/Generator Maintenance Troubleshooting HOW to USE Troubleshooting GuideContact your local Lincoln Authorized Field Service Facility Contact your local Lincoln Faulty control cable. Repair or Stick Diagrams Diagrams Diagrams Diagrams Diagrams Warni NG Diagrams Diagrams Diagrams Diagrams Diagrams Dimension Print Precaucion Atenção