Lincoln Electric 305G manual TIG Welding, Wire WELDING-CV

Page 22

B-5

OPERATION

B-5

 

 

 

TIG WELDING

The TOUCH START TIG setting of the MODE switch is for DC TIG (Tungsten Inert Gas) welding. To initiate a weld, the CONTROL dial is first set to the desired cur- rent and the tungsten is touched to the work. During the time the tungsten is touching the work there is very little voltage or current and in general, no tungsten con- tamination. Then, the tungsten is gently lifted off the work in a rocking motion, which establishes the arc.

The ARC CONTROL is not active in the TIG mode.To STOP a weld, simply pull the TIG torch away from the work. When the arc voltage reaches approximately 30 Volts the arc will go out and the machine will reset the current to the Touch Start level. To reinitiate the arc, re touch the tungsten to the work and lift. Alternatively, the weld can be stopped by releasing the Amptrol or arc start switch.

The RANGER 305G can be used in a wide variety of DC TIG welding applications. In general the ʻTouch Startʼ feature allows contamination free starting without the use of a Hi-frequency unit. If desired, the K930-2 TIG Module can be used with the Ranger 305D. The settings are for reference.

RANGER 305G settings when using the K930-2 TIG Module with an Amptrol or Arc Start Switch:

Set the MODE Switch to the TOUCH START TIG setting.

Set the "IDLER" Switch to the "AUTO" position.

Set the "WELDING TERMINALS" switch to the "REMOTELY CONTROLLED" position. This will keep the "Solid State" contactor open and provide a “cold” electrode until the Amptrol or Arc Start Switch is pressed

When using the TIG Module, the OUTPUT control on the RANGER 305G is used to set the maximum range of the CURRENT CONTROL on the TIG module or an Amptrol if connected to the TIG Module.

WIRE WELDING-CV

Connect a wire feeder to the RANGER 305G accord- ing to the instructions in INSTALLATION INSTRUC- TIONS Section.

The RANGER 305G in the CV-WIRE mode, permits it to be used with a broad range of flux cored wire (Innershield and Outershield) electrodes and solid wires for MIG welding (gas metal arc welding). Welding can be finely tuned using the ARC CON- TROL. Turning the ARC CONTROL clockwise from –10 (soft) to +10 (crisp) changes the arc from soft and washed-in to crisp and narrow. It acts as an induc- tance control. The proper setting depends on the pro- cedure and operator preference. Start with the dial set at 0.

Listed below are some wires suitable for use on this machine:

Innershield - NR-311, NS-3M, NR-207, NR-203 Ni 1%, NR-212.

Outershield - 0S-70, 0S-71M, 0S-71 ELITE.

Solid wires for MIG welding - .035 (0.9 mm), and

.045 (1.1 mm), Super Arc L-50 and L-56, .035 (0.9 mm) and

.045 (1.1 mm) Blue Max MIG 308 LS.

Contact your local authorized Lincoln Electric Distributor or the Lincoln Electric Company for specific wires used on certain applications with this machine.

TYPICAL CURRENT RANGES (1) FOR TUNGSTEN ELECTRODES(2)

Tungsten Electrode

DCEN (-)

DCEP (+)

Approximate Argon Gas Flow

 

TIG TORCH

 

Diameter in. (mm)

 

 

Flow Rate C.F.H. ( l

/min.)

 

Nozzle Size (4), (5)

 

 

1%, 2% Thoriated

1%, 2% Thoriated

Aluminum

 

 

Stainless Steel

 

 

 

 

 

Tungsten

Tungsten

 

 

 

 

 

 

 

.010

(.25)

2-15

(3)

3-8

(2-4)

 

3-8

(2-4)

#4, #5, #6

 

0.020

(.50)

5-20

(3)

5-10

(3-5)

 

5-10

(3-5)

 

 

0.040

(1.0)

15-80

(3)

5-10

(3-5)

 

5-10

(3-5)

 

 

1/16

(1.6)

70-150

10-20

5-10

(3-5)

 

9-13

(4-6)

#5, #6

 

3/32

(2.4)

150-250

15-30

13-17

(6-8)

 

11-15

(5-7)

#6, #7, #8

 

1/8

(3.2)

250-400

25-40

15-23

(7-11)

 

11-15

(5-7)

 

 

5/32

(4.0)

400-500

40-55

21-25

(10-12)

 

13-17

(6-8)

#8, #10

 

3/16

(4.8)

500-750

55-80

23-27

(11-13)

 

18-22

(8-10)

 

 

1/4

(6.4)

750-1000

80-125

28-32

(13-15)

 

23-27

(11-13)

 

 

 

 

 

 

 

 

 

 

 

 

 

(1)When used with argon gas. The current ranges shown must be reduced when using argon/helium or pure helium shielding gases.

(2)Tungsten electrodes are classified as follows by the American Welding Society (AWS):

Pure

EWP

1% Thoriated

EWTh-1

2% Thoriated

EWTh-2

Though not yet recognized by the AWS, Ceriated Tungsten is now widely accepted as a substitute for 2% Thoriated Tungsten in AC and DC applications.

(3)DCEP is not commonly used in these sizes.

(4)TIG torch nozzle "sizes" are in multiples of 1/16ths of an inch:

# 4 = 1/4 in.

(6 mm)

# 5

= 5/16 in.

(8 mm)

# 6

= 3/8 in.

(10 mm)

# 7

= 7/16 in.

(11 mm)

# 8

= _ in.

(12.5 mm)

#10 = 5/8 in.

(16 mm)

(5)TIG torch nozzles are typically made from alumina ceramic. Special applications may require lava nozzles, which are less prone to breakage, but cannot withstand high temperatures and high duty cycles.

RANGER 305G

Image 22
Contents Ranger Safety California Proposition 65 WarningsElectric Shock can kill Welding and Cutting Sparks can Cause fire or explosion Précautions DE Sûreté Sûreté Pour Soudage a LʼArcThank You Table of Contents Vii Installation Technical Specifications Ranger 305G K1726-4, K1726-5Machine Specifications Ranger 305G K1726-4, K1726-5 Receptacles and Circuit BreakersLocation and Ventilation Safety PrecautionsAdditional Safety Precautions High Altitude OperationOIL PRE-OPERATION Engine ServiceBattery Connection Gasoline FuelElectrical Connections Welding Output Cables Standby Power ConnectionsAuxiliary Power Receptacles Total Combined Length of Electrode and Work CablesConnection of Ranger 305G to Premises Wiring Connection of Lincoln Electric Wire Feeders Connection of LN-7 or LN-8 to the Ranger 305GInstallation Operation Design FeaturesGeneral Description Digital Output Meters Weld Mode Selector SwitchWelding Controls Output Control ARC ControlWire Feeder Voltmeter Switch PIN ConnectorWeld Terminals Control Switch Idler SwitchWelder Operation TIG Welding Wire WELDING-CVTypical Current Ranges 1 for Tungsten ELECTRODES2 Auxiliary Power ARC GougingAccessories Engine Maintenance Components MaintenanceKohler Engine Engine Spark Plug AIR Filter Paper ElementFuel Filter Engine AdjustmentBattery Maintenance Servicing Optional Spark ArrestorWelder/Generator Maintenance Troubleshooting HOW to USE Troubleshooting GuideContact your local Lincoln Authorized Field Service Facility Contact your local Lincoln Faulty control cable. Repair or Stick Diagrams Diagrams Diagrams Diagrams Diagrams Warni NG Diagrams Diagrams Diagrams Diagrams Diagrams Dimension Print Precaucion Atenção