Lincoln Electric 305G manual Welder Operation

Page 21

B-4

OPERATION

B-4

 

 

 

CAUTION

Operating the starter motor for more than 5 sec- onds can damage the motor. If the engine fails to start, release the switch and wait 10 seconds before operation the starter again. Do NOT push the START button while the engine is running because this can damage the ring gear and/or the starter motor.

------------------------------------------------------------------------

NOTE: When starting a RANGER 305G for the first time, or after and extended period of time of not operat- ing, it will take longer than normal because the fuel pump has to fill the fuel line and carburetor.

STOPPING

Remove all welding and auxiliary power loads and allow the engine to run at low idle speed for a few min- utes to cool the engine.

Stop the engine by placing the RUN-STOP in the STOP position.

NOTE: A fuel shut off valve is not required on the RANGER 305G because the fuel tank is mounted below the engine.

WELDER OPERATION

DUTY CYCLE

Duty Cycle is the percentage of time the load is being applied in a 10 minute period. For Example, a 60% duty cycle represents 6 minutes of load and 4 minutes of no load in a 10 minute period.

DC STICK WELDING

The RANGER 305G can be used with a broad range of DC stick electrodes.

The MODE switch provides two stick welding settings as follows:

CONSTANT CURRENT (CC-STICK) WELDING

The CC-STICK position of the MODE switch is designed for horizontal and vertical-up welding with all types of electrodes, especially low hydrogen. The out- put CONTROL dial adjusts the full output range for stick welding.

The ARC CONTROL knob sets the short circuit current during stick welding (arc-force). Increasing the number from -10 to +10 increases the short circuit current and prevents sticking of the electrode to the plate while welding. This can also increase spatter. It is recom- mended that the ARC CONTROL be set to the mini- mum number without electrode sticking. Start with the dial set at 0.

DOWN HILL PIPE WELDING

This slope controlled setting is intended for "out-of- position" and "down hill" pipe welding where the opera- tor would like to control the current level by changing the arc length. The output CONTROL dial adjusts the full output range for pipe welding.

The ARC CONTROL knob sets the short circuit current during stick welding (arc-force). Increasing the number from -10 to +10 increases the short circuit current and prevents sticking of the electrode to the plate while welding. This can also increase spatter. It is recom- mended that the ARC CONTROL be set to the mini- mum number without electrode sticking. Start with the dial set at 0.

 

TYPICAL RANGER 305G FUEL CONSUMPTION

 

Kohler CH23S

Running Time for

 

gal./hr (liters/hr)

12 gallons -(hrs.)

 

 

 

Low Idle - No Load

 

 

2400 R.P.M.

.51 (1.9)

23.5

 

 

 

High Idle - No Load

 

 

3700 R.P.M.

.83 (3.2)

14.5

 

 

 

DC Weld Output

 

 

240 Amps @ 29 Volts

1.39 (5.3)

8.6

 

 

 

DC Weld Output

 

 

300 Amps @ 29 Volts

1.53 (5.8)

7.8

 

 

 

Auxiliary Power

 

 

9,500 Watts

1.64 (6.2)

7.3

 

 

 

RANGER 305G

Image 21
Contents Ranger California Proposition 65 Warnings SafetyElectric Shock can kill Welding and Cutting Sparks can Cause fire or explosion Sûreté Pour Soudage a LʼArc Précautions DE SûretéThank You Table of Contents Vii Technical Specifications Ranger 305G K1726-4, K1726-5 InstallationReceptacles and Circuit Breakers Machine Specifications Ranger 305G K1726-4, K1726-5Additional Safety Precautions Safety PrecautionsLocation and Ventilation High Altitude OperationBattery Connection Gasoline PRE-OPERATION Engine ServiceOIL FuelElectrical Connections Auxiliary Power Receptacles Standby Power ConnectionsWelding Output Cables Total Combined Length of Electrode and Work CablesConnection of Ranger 305G to Premises Wiring Connection of LN-7 or LN-8 to the Ranger 305G Connection of Lincoln Electric Wire FeedersInstallation Design Features OperationGeneral Description Welding Controls Output Control Weld Mode Selector SwitchDigital Output Meters ARC ControlWeld Terminals Control Switch PIN ConnectorWire Feeder Voltmeter Switch Idler SwitchWelder Operation Wire WELDING-CV TIG WeldingTypical Current Ranges 1 for Tungsten ELECTRODES2 ARC Gouging Auxiliary PowerAccessories Maintenance Engine Maintenance ComponentsKohler Engine Engine AIR Filter Paper Element Spark PlugBattery Maintenance Engine AdjustmentFuel Filter Servicing Optional Spark ArrestorWelder/Generator Maintenance HOW to USE Troubleshooting Guide TroubleshootingContact your local Lincoln Authorized Field Service Facility Contact your local Lincoln Faulty control cable. Repair or Stick Diagrams Diagrams Diagrams Diagrams Diagrams Warni NG Diagrams Diagrams Diagrams Diagrams Diagrams Dimension Print Precaucion Atenção