Friedrich CP06F10, CP08F10 manual Air Handling Parts, AIR Guide and Blower

Page 10

Disassembly

AirHandlingParts

1.AIR GUIDE AND BLOWER

1.

Remove the front grille.

 

2.

Remove the cabinet.

 

3.

Remove the control box.

 

4.

Remove the 3 screws which fasten the brace.

 

5.

Remove the brace.

 

6.

Remove the 2 screws which fasten the evaporator.

 

7.

Move the evaporator forward and pulling it upward

 

 

slightly. (See Figure 4)

 

8.

Move the evaporator to the left carefully.

Figure 4

 

 

9.Pull out the hook of orifice by pushing the tabs and remove it. (See Figure 5)

10. Remove the clamp with a hand plier which secures the blower.

11. Remove the blower.

12. Remove the 4 screws which fasten the air guide from the barrier.

13. Move the air guide backward, pulling out from the base pan.

14. Re-install the components by referring to the removal procedure, above.

Figure 5

2.FAN AND SHROUD

1. Remove the cabinet.

2. Remove the brace.

3. Remove the 3 screws which fasten the condenser.

4. Move the condenser to the left carefully.

5. Remove the clamp which secures the fan.

6. Remove the fan and then pull out the shroud. (See Figure 6)

7. Re-install by referring to the removal procedure.

Figure 6

10 Room Air Conditioner

Image 10
Contents Room Air Conditioner Service and Parts Manual Table of Contents Safety Precautions Be sure not to doDo not modify power cord length Do not clean the air conditioner with water Symbols Used in this Manual DimensionsOutside Dimensions Product Specifications OperationRoom Air Conditioner Front Grille DisassemblyMechanical Parts CabinetAir Handling Parts AIR Guide and BlowerOverload Protector Electrical PartsMotor CompressorPower Cord CapacitorEvaporator Capillary TubePulling Vacuum Circuit Diagram Electronic Control Device Troubleshooting Guide Piping SystemTroubleshooting Guide Unit runs but poor coolingFails to Start Electric Parts Troubleshooting Guide Possible TroubleSet the Temp. setting to lower Temp Is the voltage No.16 CN-DISP1 on Main P.W.B Assy DC 5V? Room AIR Conditioner Voltage Limits Troubleshooting Guide Complaint Cause Remedy Exploded View Pwbpcb ASSEMBLY,DISPLAY Pwbpcb ASSEMBLY,DISPLA Use Factory Certified Parts