Disassembly

Equipment needed: Vacuum pump, Charging cylinder, Manifold gauge, Brazing equipment. Pin-off tool capable of making a vapor-proof seal, Leak detector, Tubing cutter, Hand Tools to remove components, Service valve.

 

COMPOUND GAUGE

 

 

 

CONDENSER

 

 

 

 

 

(HIGH PRESSURE SIDE)

MANIFOLD

 

 

 

 

 

 

 

 

 

GAUGE

A

 

 

 

 

B

 

 

CAPILLARY TUBE

 

 

 

 

 

 

 

SEE INSETS

 

 

 

 

 

BELOW

 

 

 

 

EVAPORATOR

 

 

 

 

(LOW PRESSURE SIDE)

 

 

 

COMPRESSOR

 

 

 

 

 

 

LOW

HI

 

 

 

A

 

A

 

 

B

B

 

 

 

 

 

 

 

 

 

EXTERNAL

 

 

 

 

 

VACUUM PUMP

 

CHARGING

 

 

 

 

 

 

 

 

 

 

CYLINDER

 

 

 

 

 

C

 

 

 

Figure 14A-Pulling Vacuum

Figure 15B-Charging

 

 

 

 

Service Manual

14

Image 14
Contents Room Air Conditioner Service and Parts Manual Table of Contents Safety Precautions Be sure not to doDo not modify power cord length Do not clean the air conditioner with water Outside Dimensions DimensionsSymbols Used in this Manual Product Specifications OperationRoom Air Conditioner Front Grille DisassemblyMechanical Parts CabinetAir Handling Parts AIR Guide and BlowerOverload Protector Electrical PartsMotor CompressorPower Cord CapacitorEvaporator Capillary TubePulling Vacuum Circuit Diagram Electronic Control Device Troubleshooting Guide Piping SystemTroubleshooting Guide Unit runs but poor coolingFails to Start Electric Parts Troubleshooting Guide Possible TroubleSet the Temp. setting to lower Temp Is the voltage No.16 CN-DISP1 on Main P.W.B Assy DC 5V? Room AIR Conditioner Voltage Limits Troubleshooting Guide Complaint Cause Remedy Exploded View Pwbpcb ASSEMBLY,DISPLAY Pwbpcb ASSEMBLY,DISPLA Use Factory Certified Parts