Friedrich CP06F10, CP08F10 manual Electric Parts Troubleshooting Guide, Possible Trouble

Page 20

Troubleshooting Guide

ELECTRIC PARTS TROUBLESHOOTING GUIDE:

Possible Trouble 1

Is the Trans input power AC 115V?

YES

Is the Trans output power

about AC 14V?

YES

Is output Voltage of IC01D

DC 12V?

YES

Is output Voltage of IC02D

DC 5V?

YES

• The unit does not operate.

NO

 

• Check the Fuse.

 

 

 

 

 

 

• Check the wiring diagram.

 

 

 

 

 

 

 

 

 

 

 

NO

 

NO

 

• Check the Main

 

 

 

 

 

Is shorted the Trans. output?

 

 

P.W.B pattern.

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Exchange the Trans.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO

 

 

 

 

 

Exchange D02D~D05D.

 

 

 

 

 

 

 

• Exchange IC01D.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO

• Exchange IC02D.

 

Is the reset circuit all right?

(The No.14 of Micom

is 5V.)

YES

Is the

connection between

Main and Display

all right?

YES

NO

NO

• Exchange IC01A.

Connect connector exactly.

Is the voltage No.18 of Micom

NO

 

• Check the P.W.B

 

 

 

 

 

 

pattern.

 

 

 

 

DC 5V?

 

 

 

 

 

 

 

 

 

YES

Exchange Main P.W.B Ass'y.

Service Manual 20

Image 20
Contents Room Air Conditioner Service and Parts Manual Table of Contents Safety Precautions Be sure not to doDo not modify power cord length Do not clean the air conditioner with water Outside Dimensions DimensionsSymbols Used in this Manual Product Specifications OperationRoom Air Conditioner Disassembly Mechanical PartsFront Grille CabinetAir Handling Parts AIR Guide and BlowerElectrical Parts MotorOverload Protector CompressorPower Cord CapacitorEvaporator Capillary TubePulling Vacuum Circuit Diagram Electronic Control Device Troubleshooting Guide Piping SystemTroubleshooting Guide Unit runs but poor coolingFails to Start Electric Parts Troubleshooting Guide Possible TroubleSet the Temp. setting to lower Temp Is the voltage No.16 CN-DISP1 on Main P.W.B Assy DC 5V? Room AIR Conditioner Voltage Limits Troubleshooting Guide Complaint Cause Remedy Exploded View Pwbpcb ASSEMBLY,DISPLAY Pwbpcb ASSEMBLY,DISPLA Use Factory Certified Parts