Friedrich CP08F10, CP06F10 manual Disassembly, Mechanical Parts, Front Grille, Cabinet, Control BOX

Page 9

Disassembly

Disassembly

— Before the following disassembly, POWER SWITCH set to OFF and disconnect the power cord.

MechanicalParts

1.FRONT GRILLE

1.Open the lnlet grille upward or downward.

2.Remove the screw which fastens the front grille.

3.Pull the front grille from the right side.

4. Remove the front grille.

5. Re-install the component by referring to the removal procedure, above.(See Figure 1)

Figure 1

2.CABINET

1.After disassembling the FRONT GRILLE, remove the 2 screws which fasten the cabinet at both

sides.

2. Remove the 2 screws which fasten the cabinet at back.

3. Pull the base pan forward. (See Figure 2)

4. Remove the cabinet.

5. Re-install the component by referring to the removal procedure, above.

Figure 2

3.CONTROL BOX

1.Disconnect the unit from the power source.

2. Remove the front grille.

3. Remove the cabinet.

4. Remove the screw which fastens the control box cover.

5.Remove the housing which connects motor wire in the control box.

6. Remove the 3 leads from the compressor. 7.Discharge the capacitor by placing a 20,000 ohmresistor across the capacitor terminals.

8. Remove the 2 screws which fasten the control box.(See Figure 3)

9. Pull the control box forward completely.

10. Re-install the components by referring to the removal procedure, above. (See Figure 3)

Figure 3

Service Manual 9

Image 9
Contents Room Air Conditioner Service and Parts Manual Table of Contents Be sure not to do Safety PrecautionsDo not modify power cord length Do not clean the air conditioner with water Dimensions Symbols Used in this ManualOutside Dimensions Operation Product SpecificationsRoom Air Conditioner Mechanical Parts DisassemblyFront Grille CabinetAIR Guide and Blower Air Handling PartsMotor Electrical PartsOverload Protector CompressorCapacitor Power CordCapillary Tube EvaporatorPulling Vacuum Circuit Diagram Electronic Control Device Piping System Troubleshooting GuideUnit runs but poor cooling Troubleshooting GuideFails to Start Possible Trouble Electric Parts Troubleshooting GuideSet the Temp. setting to lower Temp Is the voltage No.16 CN-DISP1 on Main P.W.B Assy DC 5V? Room AIR Conditioner Voltage Limits Troubleshooting Guide Complaint Cause Remedy Exploded View Pwbpcb ASSEMBLY,DISPLAY Pwbpcb ASSEMBLY,DISPLA Use Factory Certified Parts