PROBLEM | CAUSE | CORRECTION |
Compressor is | Prolonged excessive use of | Decrease amount of air |
not supplying | air. | usage. |
enough air to |
| Check the accessory air |
operate | Compressor is not large | |
accessories. | enough for air requirement. | requirement. If it is higher |
|
| than the SCFM or pressure |
|
| supplied by your air |
|
| compressor, you need a |
|
| larger compressor. |
| Hole in hose. | Check and replace if |
|
| required. |
| Air leaks. | Tighten any exposed fittings. |
|
|
|
Motor will not | Fuse blown, circuit breaker | Check fuse box for blown |
run. | tripped. | fuse and replace as |
|
| necessary. Reset circuit |
|
| breaker. Do not use a fuse or |
|
| circuit breaker with higher |
|
| rating than that specified for |
|
| your particular branch circuit. |
|
| Check for proper fuse. You |
|
| should use a time delay fuse. |
|
| Check for low voltage |
|
| problem. |
|
| Check the extension cord. |
|
| Disconnect the other |
|
| electrical appliances from |
|
| circuit or operate the |
|
| compressor on its own |
|
| branch circuit. |
| Extension cord is wrong | Check the extension cord. |
| length or gauge. |
|
| Loose electrical | Check wiring connection |
| connections. | inside terminal box. |
| Faulty motor. | Have checked by a Trained |
|
| Service Technician. |
|
|
|
19- ENG | D29495 |