Campbell Hausfeld FP2000 operating instructions Description, General Safety, Safety Guidelines

Page 1

See Warranty on page 8 for important information about commercial use of this product.

Operating Instructions

FP2000, FP2012

 

 

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference.

Oil Lubricated

Portable Air

Compressors

Description

The Campbell Hausfeld portable contractor air compressor is intended for use in construction and workshop conditions. An oil lubricated, electric motor driven compressor provides compressed air to power nailers, staplers, paint guns and other air tools. The compressed air produced by the unit will contain traces of oil and water. In-line filters may be required for some applications.

A pressure switch shuts off the compressor when the tank is filled to 125 PSI. When air is used and the tank pressure drops to 100 PSI, the compressor will restart automatically. The regulator may be set to provide a line pressure lower than the tank pressure.

The valve on the compressor outlet fitting vents air for ease in motor startup.

NOTICE

The sound of vented

air is especially

noticeable when the tank pressure is low and is not a defect.

The pressure switch also has an unloader valve to vent air when the compressor stops.

Safety Guidelines

This manual contains information that is very important to know and understand. This information is provided for SAFETY and to PREVENT EQUIPMENT PROBLEMS. To help recognize this information, observe the following symbols.

Danger indicates

! DANGER an imminently hazardous situation which, if not avoided, will result in death or serious injury.

Warning indicates

! WARNING a potentially hazardous situation which, if not avoided, could result in death or serious injury.

Caution indicates a

! CAUTION potentially hazardous situation which, if not avoided, MAY result in minor or moderate injury.

Notice indicates

NOTICE important information, that if not followed, may cause damage to equipment.

Unpacking

When unpacking unit, inspect carefully for any damage that may have occurred during transit. Make sure to tighten fittings, bolts, etc., before putting unit into service.

General Safety

Do not operate ! WARNING unit if damaged

during shipping, handling or use. Damage may result in bursting and cause injury or property damage.

Air compressors are utilized in a variety of air system applications. Because air compressors and other components (material pump, spray gun, filters, lubrications, hoses, etc.) used make up a high pressure pumping system, the following safety precautions should be observed at all times. Only persons well acquainted with these rules of safe operation should be allowed to use the air compressor.

1.Read all manuals included with this

product carefully. Be

thoroughly familiar MANUAL with the controls and

the proper use of the equipment.

2.Keep visitors away and NEVER allow children in the work area.

3.Before each use, inspect compressed

!DANGER

Breathable Air Warning

This compressor/pump is NOT equipped and should NOT be used “as is” to supply breathing quality air. For any application of air for human consumption, the air compressor/pump will need to be fitted with suitable in-line safety and alarm equipment. This additional equipment is necessary to properly filter and purify the air to meet minimal specifications for Grade D breathing as described in Compressed Gas Association Commodity Specification G 7.1 - 1966, OSHA 29 CFR 1910. 134, and/or Canadian Standards Associations (CSA).

DISCLAIMER OF WARRANTIES

IN THE EVENT THE COMPRESSOR IS USED FOR THE PURPOSE OF BREATHING AIR APPLICATION AND PROPER IN-LINE SAFETY AND ALARM EQUIPMENT IS NOT SIMULTANEOUSLY USED, EXISTING WARRANTIES SHALL BE VOIDED, AND CAMPBELL HAUSFELD DISCLAIMS ANY LIABILITY WHATSOEVER FOR ANY LOSS, PERSONAL INJURY OR DAMAGE.

air system and electrical components for signs of damage, deterioration, weakness or leakage. Repair or replace defective items before using.

4.Check all fasteners at frequent intervals for proper tightness.

5.Do not exceed pressure rating of any component in system.

REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.

© 2002 Campbell Hausfeld/Scott Fetzer

For parts, product & service information

IN608400AV 10/02

visit www.chpower.com

Image 1
Contents Safety Guidelines General SafetyDescription UnpackingDo not stand on or use the pump or unit as a handhold Oil Lubricated Portable Air CompressorPreparation AssemblyOperation Maintenance Storage Do not disassemble check valve With air in tank bleed tank Troubleshooting ChartLimited Warranty Généralités sur la Sécurité DescriptionAvertissement D’Air Respirable Instructions d’UtilisationCompresseur d’Air Portatif Avec Huile Avertissement NejamaisMontage Généralités sur la Sécurité SuitePréparation Fonctionnement Préparation SuiteCordons Prolongateurs Pour UN Fonctionnement Sans SouciFonctionnement Suite Guide de Dépannage Entretien SuiteGuide de Dépannage Suite LA Présente Garantie NE Couvre PAS Garantie LimitéeAdvertencia indica DescripciónAdvertencia utilizar la Compresores de Aire Portátiles Lubricados con Aceite Advertencia desInformaciones Generales de Seguridad Continuación Juego de Piezas FP2000, FP2012Preparación Funcionamiento Para Evitar Problemas DE FuncionamientoCordones DE Extension Periodo DE USO InicialFuncionamiento Continuación Advertencia reemMantenimiento Mantenimiento Continuación Advertencia EstecomGuía de diagnóstico de averías Guía de diagnóstico de averías Continuación Problema Posibles Causas Acción a tomar24 Sp Garantía Limitada