Campbell Hausfeld FP2000, FP2012 operating instructions Maintenance

Page 5

Operating Instructions

FP2000, FP2012

Operation (Cont.)

2.Turning knob clockwise increases air pressure at outlet.

3.Turning counterclockwise will lower air pressure at outlet.

4.Fully counterclockwise will shut off flow of air completely.

CloseOpen

 

Attach

Figure 8

Hose

 

REGULATED OUTLET GAUGE

2.Pull ring on safety valve and allow it to snap back to normal position.

Figure 10

! WARNING Safety valve must be replaced if it cannot be actuated or it leaks air after ring is released.

3.Turn power OFF and clean dust and dirt from motor, tank, air lines and pump cooling fins.

OIL CHANGE

1.Allow compressor to run and warm up oil.

2.Position a pan under pump end of unit.

3.Unplug unit. Remove drain plug, allow oil to collect in pan. Tilt unit to completely drain.

4.Replace drain plug, fill pump to full line on dipstick. Use Chevron synthetic 5W-30, Mobil 1 5W-30 or 0W-30 synthetic motor oil. Using other types of oil will cause starting problems.

AIR FILTER MAINTENANCE

1. This gauge shows at-a-glance, air

TANK DRAINAGE

pressure at outlet. Air pressure is

1. Daily with compressor shut off:

measured in pounds per square inch

Drain moisture from tanks by

(PSI).

opening drain cocks underneath

2. Be sure this gauge reads ZERO

end of tanks.

before changing air tools or

2. There are two drain cocks, one for

disconnecting hose from outlet.

each tank. Open both by turning

 

 

counter-clockwise.

 

 

3. Tilt unit to drain liquid. Dispose of

 

 

 

condensation properly according to

 

 

 

all laws and regulations.

Figure 9

 

 

 

TANK PRESSURE GAUGE

 

 

Gauge shows pressure in air receiver

 

Drain

indicating compressor is building pressure

 

properly.

 

 

Cock

 

 

Open

! WARNING

Release all

 

 

 

pressure and

 

 

disconnect power before making any

 

 

repair.

 

 

 

Maintenance

 

Drain

 

 

 

 

 

 

Cock

1. Check compressor for any visible

Tilt to drain

problems, especially check oil level

Figure 11

to be sure it is at full line.

MAINTENANCE SCHEDULE

 

 

Operation

 

Daily

Monthly

Drain Tank

 

 

Check Oil Level

 

 

Check Safety Valve

 

Change Oil

 

 

Clean Air Filter

● (More often

 

in dusty conditions)

1.Locate and remove the two Phillips head screws on the top of the air deflector over the cylinder head of the pump.

2.Lift off cover to expose the air filter.

3.Remove filter. Clean with air blast or soap and water. Replace filter if clogged or damaged.

4.Replace air deflector and screws. Do not operate without air deflector as the pump will overheat and become damaged.

Phillips Head Screws

Deflector

Filter

Figure 12

THERMAL OVERLOAD PROTECTOR

This compressor is

! WARNING equipped with a automatic reset thermal overload protector which will shut off motor if it becomes overheated. Motor can automatically restart at any time. Keep away from moving parts at all times.

www.chpower.com

5

Image 5
Contents Safety Guidelines General SafetyDescription UnpackingDo not stand on or use the pump or unit as a handhold Oil Lubricated Portable Air CompressorPreparation AssemblyOperation Maintenance Storage Do not disassemble check valve With air in tank bleed tank Troubleshooting ChartLimited Warranty Généralités sur la Sécurité DescriptionAvertissement D’Air Respirable Instructions d’UtilisationCompresseur d’Air Portatif Avec Huile Avertissement NejamaisPréparation Généralités sur la Sécurité SuiteMontage Fonctionnement Préparation SuiteCordons Prolongateurs Pour UN Fonctionnement Sans SouciFonctionnement Suite Guide de Dépannage Entretien SuiteGuide de Dépannage Suite LA Présente Garantie NE Couvre PAS Garantie LimitéeAdvertencia utilizar la DescripciónAdvertencia indica Informaciones Generales de Seguridad Continuación Advertencia desCompresores de Aire Portátiles Lubricados con Aceite Preparación FP2000, FP2012Juego de Piezas Funcionamiento Para Evitar Problemas DE FuncionamientoCordones DE Extension Periodo DE USO InicialMantenimiento Advertencia reemFuncionamiento Continuación Guía de diagnóstico de averías Advertencia EstecomMantenimiento Continuación Guía de diagnóstico de averías Continuación Problema Posibles Causas Acción a tomar24 Sp Garantía Limitada