°F vs. °C Display

The unit is factory configured to display all temperatures in degrees Fahrenheit (° F). To switch to degrees Celsius press the ‘Fan Only’ and ‘Low Fan’ buttons simultaneously for three seconds. The display will show a ‘C’ as acknowledgement of the change. To revert back to ° F press the ‘Fan Only’ and ‘Low Fan’ buttons simultaneously for three seconds. The display will show an ‘F’ as acknowledgement of the change.

Cooling Mode

Pressing the ‘Cool’ button while the unit is in any mode, including off, will put the unit into cooling mode. Adjust the temperature readout to the desired room temperature and the unit will cycle the compressor on and off to maintain a comfortable room. The compressor will come on anytime that the room temperature is 1.8° F above the desired temperature. The fan operation is dependent on the fan mode selected, either continuous or cycling. See Fan Mode for fan cycle control.

Heating Mode

Pressing the ‘Heat’ button while the unit is in any mode, including off, will put the unit into heating mode.

Heat Pump Models (PDH)

When the ‘Heat’ button is pressed initially the unit will energize the electric resistance heat to quickly bring the room to the set temperature. When the desired room temperature falls 1.8° F below the desired set temperature the unit will cycle the compressor on and operate as a heat pump to maintain the room temperature while running more efficiently than resistance heat only models. If the room temperature should fall more than 5° F from the set temperature the unit will run the resistance heater. The fan operation is dependent on the fan mode selected, either continuous or cycling. Dip switch 3 controls the fan mode, see page 23 for setting.

When the outdoor coil temperature falls below 30° F for more than 2 min- utes the unit will operate the resistance heaters and not the compressor. When the outdoor coil temperature reaches 45° F the compressor will be allowed to operate again.

FRP030

Heat/Cool Models (PDE)

After pressing the ‘Heat’ button, adjust the temperature readout to the desired room temperature and the unit will cycle the resistance heat on and off to maintain a comfortable room. The heater will come on anytime that the room temperature is 1.8° F below the desired temperature. The fan operation is dependent on the fan mode selected, either continuous or cycling. Dip switch 3 controls the fan mode, see page 23 for setting.

Emergency Heat Operation

In the event of a compressor failure in heat pump mode the compressor may be locked out to provide heat through the resistance heater. This feature ensures that even in the unlikely event of a compressor failure the room temperature can be maintained until the compressor can be serviced. Dip switch 1 controls the emergency heat setting, see page 23.

Fan Mode

All units are shipped with fan mode set to continuous for cooling and cycle for heating.

Fan Only Mode

Pressing the ‘Fan’ button will run the fan to allow for air circulation in the room without operating the compressor or heater regardless of the room or set temperature. The fan speed selection is made by pressing either the ‘High Fan’, ‘Med Fan’ or ‘Low Fan’ button.

Cycle/Continuous

The owner may choose between fan cycling or fan continuous mode based on property preference (Note: Even heat monitoring and quiet start/stop fan delay only operate in fan cycle mode). Fan continuous mode is used to keep constant airflow circulation in the room during all times the unit is ‘ON’. Fan cycle will conserve energy by only operating the fan while the compressor or electric heater is operating. Dip switch 3-4 controls the fan mode, see page 23 for setting.

24

Image 24
Contents Ptac Table of Contents Read Installation Operation Manual CongratulationsGeneral Instructions General Specifications Installation ChecklistPtac Installation Recommendations Typical Building Plan ViewWall Sleeve Installation Instructions Pdxws For Deep Wall Installation Greater than 13 1/4 SeeTypical Wall Sleeve Installation Falling Object HazardAlternate Wall Installations Panel WallFrame and Brick Veneer Curtain WallDimensions Wall Sleeve AttachmentOne-Piece Deep Wall Sleeve Installation Pdxwsext Lintel InstallationDrain Kit Location and Installation Internal DrainCover Plate Installation Drain Tube Installation See FigureDrain Kit Installation Pxga Standard Grille Installation Instructions Standard GrillePower Cord Information 230/208V models only All 230/208 volt units are equipped with power cordsElectrical Rating Tables Electrical Wiring for 265 Volt Models Power Cord InstallationElectrical Shock Hazard To Chassis Junction Chassis Install Preparation Suffocation HazardsUnit Damage Hazard Shipping Tape LocationShipping Screw Location Chassis Installation Excessive Weight HazardSecuring Unit How To Connect Power ConnectionFriedrich Ptac Digital Control and Unit Features Page System Configuration Digital Control User Input Configuration Dip Switch SettingDip Switches Digital Control Operation Remote Control Thermostat Installation Desk Control Terminals Energy ManagementRoutine Maintenance Basic Troubleshooting Complaint Cause SolutionService & Assistance Accessories New Construction AccessoriesPxcja Friedrich Packaged Terminal AIR Conditioners and Heat Pumps This page Intentionally Left Blank This page Intentionally Left Blank This page Intentionally Left Blank

920-087-09 (12/10) specifications

The Friedrich 920-087-09 (12/10) is a remarkable air conditioning unit that exemplifies innovation in climate control technology. Designed for both residential and commercial environments, this model stands out for its efficiency, reliability, and user-friendly features.

One of the key characteristics of the Friedrich 920-087-09 is its impressive cooling capacity. With a nominal cooling power of 12,000 BTU, it is ideal for medium to large spaces, effortlessly maintaining comfortable indoor temperatures even during the hottest months. The unit offers a seasonal energy efficiency ratio (SEER) that meets contemporary standards, ensuring that it operates efficiently while consuming less energy. This feature not only lowers electricity bills but also reduces the overall environmental impact.

The Friedrich 920-087-09 is equipped with advanced inverter technology, allowing it to adjust its cooling power according to the temperature needs of the room. This results in quieter operation and enhanced energy savings as the unit avoids the frequent on-off cycles typical of conventional systems. Furthermore, the unit boasts a variable-speed compressor that guarantees consistent performance and improved humidity control.

Another standout feature of the Friedrich 920-087-09 is its sophisticated air filtration system. It includes a washable filter that captures dust, pollen, and other airborne particles, promoting cleaner air quality. This is particularly beneficial for those with allergies or respiratory issues, creating a healthier living environment.

The unit also features a customizable digital thermostat that allows users to set precise temperature preferences. With its user-friendly interface, users can easily switch between different modes, including cooling, heating, and dehumidifying, adding to the flexibility of the system. Additionally, Friedrich's exclusive Quiet Master technology minimizes noise levels, making it suitable for bedrooms, offices, and other quiet areas.

The Friedrich 920-087-09 also comes with a range of connectivity options, including Wi-Fi integration. This functionality allows users to control the air conditioning unit remotely through a smartphone app, making it exceptionally convenient for those with busy lifestyles.

Overall, the Friedrich 920-087-09 (12/10) combines cutting-edge technology, energy efficiency, and a host of user-friendly features, making it a top choice for anyone looking to enhance their indoor comfort. Its design is not only functional but also aesthetically pleasing, allowing it to blend seamlessly with a variety of interiors.