Friedrich 920-087-09 (12/10) operation manual Congratulations, General Instructions

Page 3

Congratulations

Thank you for your decision to purchase Friedrich. Your new Friedrich has been carefully engineered and manufactured to give you many years of dependable, efficient operation, maintaining a comfortable temperature and humidity level. Many extra features have been built into your unit to assure quiet operation, the greatest circulation of cool, dry air, and the most economic operation.

General Instructions

This Installation and Operation Manual has been designed to insure maximum satisfaction in the performance of your unit. For years of trouble-free service, please follow the installation instructions closely. We cannot overemphasize the importance of proper installation.

WARNING

Refrigeration system under high pressure

Do not puncture, heat, expose to flame or incinerate.

Only certified refrigeration technicians should service this equipment.

R410A systems operate at higher pressures than R22 equipment. Appropriate safe service and handling practices must be used.

Only use gauge sets designed for use with R410A. Do not use standard R22 gauge sets.

Here are some suggestions to help you use your new Friedrich most efficiently:

1.Carefully read and follow the installation instructions.

2.Make sure the unit is the right capacity for the area being cooled. An undersized unit makes the unit work too hard, using more electricity than needed and increases wear. An oversized unit will cycle on and off too rapidly, and therefore cannot control humidity as well.

3.Clean the filter frequently (See Routine Maintenance, Page 27).

4.Do not block the air flow to and from the unit.

5.A dirty filter or improperly set controls can affect the cooling ability of the unit.

6.If cooling is weak and you have verified that the filter is clean

and the controls are properly set, the unit may need service and you should call your Friedrich service provider to check the unit.

7.Keep blinds, shades and drapes closed on the sunny side of the room being cooled to reduce radiant heat.

8.Proper insulation helps your unit maintain the desired inside temperature.

9.Whenever possible, shade south and west facing windows.

10.Keep window coverings away from the unit to provide free air flow.

WARNING

Read Installation Operation

Manual

Please read this manual thoroughly prior to equipment installation or operation.

It is the installer’s responsibility to properly apply and install the equipment. Installation must be in conformance with the NFPA 70 -2008 National Electric Code or current edition, International Mechanic Code 2009 or current edition and any other applicable local or national codes.

Failure to do so can result in property damage, personal injury or death.

Your safety and the safety of others are very important.

We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.

This is a safety Alert symbol.

This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will follow the safety alert symbol with the word “WARNING” or “CAUTION”. These words mean:

WARNIING

CAUTION

Indicates a hazard which, if not avoided, can result in severe personal injury or death and damage to product or other property.

Indicates a hazard which, if not avoided, can result in personal injury and damage to product or other property.

All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what will happen if the instructions are not followed.

NOTICE

Indicates property damage can occur if instructions are not followed.

3

Image 3
Contents Ptac Table of Contents Read Installation Operation Manual CongratulationsGeneral Instructions Installation Checklist General SpecificationsTypical Building Plan View Ptac Installation RecommendationsFalling Object Hazard Wall Sleeve Installation Instructions PdxwsFor Deep Wall Installation Greater than 13 1/4 See Typical Wall Sleeve InstallationCurtain Wall Alternate Wall InstallationsPanel Wall Frame and Brick VeneerWall Sleeve Attachment DimensionsLintel Installation One-Piece Deep Wall Sleeve Installation PdxwsextInternal Drain Drain Kit Location and InstallationCover Plate Installation Drain Tube Installation See FigureDrain Kit Installation Standard Grille Pxga Standard Grille Installation InstructionsPower Cord Information 230/208V models only All 230/208 volt units are equipped with power cordsElectrical Rating Tables Electrical Wiring for 265 Volt Models Power Cord InstallationElectrical Shock Hazard To Chassis Junction Suffocation Hazards Chassis Install PreparationUnit Damage Hazard Shipping Tape LocationShipping Screw Location Chassis Installation Excessive Weight HazardSecuring Unit Power Connection How To ConnectFriedrich Ptac Digital Control and Unit Features Page System Configuration Digital Control User Input Configuration Dip Switch SettingDip Switches Digital Control Operation Remote Control Thermostat Installation Energy Management Desk Control TerminalsRoutine Maintenance Complaint Cause Solution Basic TroubleshootingService & Assistance New Construction Accessories AccessoriesPxcja Friedrich Packaged Terminal AIR Conditioners and Heat Pumps This page Intentionally Left Blank This page Intentionally Left Blank This page Intentionally Left Blank

920-087-09 (12/10) specifications

The Friedrich 920-087-09 (12/10) is a remarkable air conditioning unit that exemplifies innovation in climate control technology. Designed for both residential and commercial environments, this model stands out for its efficiency, reliability, and user-friendly features.

One of the key characteristics of the Friedrich 920-087-09 is its impressive cooling capacity. With a nominal cooling power of 12,000 BTU, it is ideal for medium to large spaces, effortlessly maintaining comfortable indoor temperatures even during the hottest months. The unit offers a seasonal energy efficiency ratio (SEER) that meets contemporary standards, ensuring that it operates efficiently while consuming less energy. This feature not only lowers electricity bills but also reduces the overall environmental impact.

The Friedrich 920-087-09 is equipped with advanced inverter technology, allowing it to adjust its cooling power according to the temperature needs of the room. This results in quieter operation and enhanced energy savings as the unit avoids the frequent on-off cycles typical of conventional systems. Furthermore, the unit boasts a variable-speed compressor that guarantees consistent performance and improved humidity control.

Another standout feature of the Friedrich 920-087-09 is its sophisticated air filtration system. It includes a washable filter that captures dust, pollen, and other airborne particles, promoting cleaner air quality. This is particularly beneficial for those with allergies or respiratory issues, creating a healthier living environment.

The unit also features a customizable digital thermostat that allows users to set precise temperature preferences. With its user-friendly interface, users can easily switch between different modes, including cooling, heating, and dehumidifying, adding to the flexibility of the system. Additionally, Friedrich's exclusive Quiet Master technology minimizes noise levels, making it suitable for bedrooms, offices, and other quiet areas.

The Friedrich 920-087-09 also comes with a range of connectivity options, including Wi-Fi integration. This functionality allows users to control the air conditioning unit remotely through a smartphone app, making it exceptionally convenient for those with busy lifestyles.

Overall, the Friedrich 920-087-09 (12/10) combines cutting-edge technology, energy efficiency, and a host of user-friendly features, making it a top choice for anyone looking to enhance their indoor comfort. Its design is not only functional but also aesthetically pleasing, allowing it to blend seamlessly with a variety of interiors.