Final Inspection & Start-up Checklist

qInspect and ensure that all components and accessories have been installed properly and that they have not been damaged during the installation process.

qCheck the condensate water drain(s) to ensure they are adequate for the removal of condensate water, and that they meet the approval of the end user.

qEnsure that all installations concerning clearances around the unit have been adhered to. Check to ensure that the unit air filter, indoor coil, and outdoor coil are free from any obstructions.

qEnsure that the entire installation is in compliance with all applicable national and local codes and ordinances that have jurisdiction.

qSecure components and accessories, such as the chassis, decorative front cover and control door.

qStart the unit and check for proper operation of all components in each mode of operation. Instruct the owner or operator of this units operation, and the manufacturer’s recommended routine maintenance schedule.

NOTE: A log for recording the dates of maintenance and/or service is recommended.

qPresent the owner or operator of the equipment with the Installation & Operation manual, all accessory installation instructions, and the name, address and telephone number of the Authorized Friedrich Warranty Service Company in the area for future reference if necessary.

Routine Maintenance

To ensure proper unit operation and life expectancy the following mainte- nance procedures should be performed on a regular basis.

WARNING

Electrical Shock Hazard

Unplug Unit or turn off electrical power to unit prior to performing maintenance procedures.

Failure to do so can result in electrical shock or death.

Air Filter

To ensure proper unit operation, the air filters should be cleaned at least monthly, and more frequently if conditions warrant. The unit must be turned off before the filters are cleaned.

To remove the air filters, grasp the top of the filter and lift out of the front cabinet. Reverse the procedure to reinstall the filters.

Clean the filters with a mild detergent in warm water, and allow them to dry thoroughly before reinstalling.

Coils & Chassis

NOTE: Do not use a caustic coil cleaning agent on coils or base pan. Use a biodegradable cleaning agent and degreaser. The use of harsh cleaning materials may lead to deterioration of the aluminum fins or the coil end plates.

The indoor coil and outdoor coils and base pan should be inspected pe- riodically (annually or semi-annually) and cleaned of all debris (lint, dirt. leaves, paper, etc.) as necessary. Under extreme conditions, more frequent cleaning may by required. Clean the coils and base pan with a soft brush and compressed air or vacuum. A pressure washer may also be used,

however, you must be careful not to bend the aluminium fin pack. Use a sweeping up and down motion in the direction of the vertical aluminium fin pack when pressure cleaning coils.

NOTE: It is extremely important to insure that none of the electrical and/or electronic parts of the unit get wet. Be sure to cover all electrical components to protect them from water or spray.

Decorative Front

The decorative front and discharge air grille may be cleaned with a mild soap or detergent. Do NOT use solvents or hydrocarbon based cleaners such as acetone, naphtha, gasoline, benzene, etc., to clean the decorative front or air discharge grilles.

Use a damp (not wet) cloth when cleaning the control area to prevent water from entering the unit, and possibly damaging the electronic control.

Fan Motor & Compressor

The fan motor & compressor and are permanently lubricated, and require no additional lubrication.

Wall Sleeve

Inspect the inside of the wall sleeve and drain system periodically (annually or semi-annually) and clean as required.

Under extreme conditions, more frequent cleaning may be necessary. Clean both of these areas with an antibacterial and antifungal cleaner. Rinse both items thoroughly with water and ensure that the drain outlets are operating correctly. Check the sealant around the sleeve and reseal areas as needed.

27

Image 27
Contents Ptac Table of Contents Read Installation Operation Manual CongratulationsGeneral Instructions Installation Checklist General SpecificationsTypical Building Plan View Ptac Installation RecommendationsFalling Object Hazard Wall Sleeve Installation Instructions PdxwsFor Deep Wall Installation Greater than 13 1/4 See Typical Wall Sleeve InstallationCurtain Wall Alternate Wall InstallationsPanel Wall Frame and Brick VeneerWall Sleeve Attachment DimensionsLintel Installation One-Piece Deep Wall Sleeve Installation PdxwsextInternal Drain Drain Kit Location and InstallationCover Plate Installation Drain Tube Installation See FigureDrain Kit Installation Standard Grille Pxga Standard Grille Installation InstructionsPower Cord Information 230/208V models only All 230/208 volt units are equipped with power cordsElectrical Rating Tables Electrical Wiring for 265 Volt Models Power Cord InstallationElectrical Shock Hazard To Chassis Junction Suffocation Hazards Chassis Install PreparationUnit Damage Hazard Shipping Tape LocationShipping Screw Location Chassis Installation Excessive Weight HazardSecuring Unit Power Connection How To ConnectFriedrich Ptac Digital Control and Unit Features Page System Configuration Digital Control User Input Configuration Dip Switch SettingDip Switches Digital Control Operation Remote Control Thermostat Installation Energy Management Desk Control TerminalsRoutine Maintenance Complaint Cause Solution Basic TroubleshootingService & Assistance New Construction Accessories AccessoriesPxcja Friedrich Packaged Terminal AIR Conditioners and Heat Pumps This page Intentionally Left Blank This page Intentionally Left Blank This page Intentionally Left Blank

920-087-09 (12/10) specifications

The Friedrich 920-087-09 (12/10) is a remarkable air conditioning unit that exemplifies innovation in climate control technology. Designed for both residential and commercial environments, this model stands out for its efficiency, reliability, and user-friendly features.

One of the key characteristics of the Friedrich 920-087-09 is its impressive cooling capacity. With a nominal cooling power of 12,000 BTU, it is ideal for medium to large spaces, effortlessly maintaining comfortable indoor temperatures even during the hottest months. The unit offers a seasonal energy efficiency ratio (SEER) that meets contemporary standards, ensuring that it operates efficiently while consuming less energy. This feature not only lowers electricity bills but also reduces the overall environmental impact.

The Friedrich 920-087-09 is equipped with advanced inverter technology, allowing it to adjust its cooling power according to the temperature needs of the room. This results in quieter operation and enhanced energy savings as the unit avoids the frequent on-off cycles typical of conventional systems. Furthermore, the unit boasts a variable-speed compressor that guarantees consistent performance and improved humidity control.

Another standout feature of the Friedrich 920-087-09 is its sophisticated air filtration system. It includes a washable filter that captures dust, pollen, and other airborne particles, promoting cleaner air quality. This is particularly beneficial for those with allergies or respiratory issues, creating a healthier living environment.

The unit also features a customizable digital thermostat that allows users to set precise temperature preferences. With its user-friendly interface, users can easily switch between different modes, including cooling, heating, and dehumidifying, adding to the flexibility of the system. Additionally, Friedrich's exclusive Quiet Master technology minimizes noise levels, making it suitable for bedrooms, offices, and other quiet areas.

The Friedrich 920-087-09 also comes with a range of connectivity options, including Wi-Fi integration. This functionality allows users to control the air conditioning unit remotely through a smartphone app, making it exceptionally convenient for those with busy lifestyles.

Overall, the Friedrich 920-087-09 (12/10) combines cutting-edge technology, energy efficiency, and a host of user-friendly features, making it a top choice for anyone looking to enhance their indoor comfort. Its design is not only functional but also aesthetically pleasing, allowing it to blend seamlessly with a variety of interiors.