Friedrich 920-087-09 (12/10) operation manual Basic Troubleshooting, Complaint Cause Solution

Page 28

Basic Troubleshooting

 

COMPLAINT

 

CAUSE

 

SOLUTION

 

 

●●

Unit turned off.

●●

Turn unit on

 

 

●●

Thermostat is satisfied.

●●

Raise/Lower temperature setting.

 

 

●● LCDI power cord is unplugged.

●● Plug into a properly grounded 3 prong recep-

 

 

 

 

 

tacle. See "Electrical Rating Tables" on page

 

 

 

 

 

13 for the proper receptacle type for your unit.

 

Unit does not operate.

●● LCDI power cord has tripped.

●● Press and release RESET (listen for click;

 

 

 

 

Reset button latches and remains in) to

 

 

 

 

 

 

 

 

 

 

resume operation.

 

 

●● Circuit breaker has tripped.

●● Reset the circuit breaker.

 

 

●● Supply circuit fuse has blown.

●●

Replace the fuse.

 

 

●●

Local power failure.

●● Unit will resume normal operation once power

 

 

 

 

 

has been restored.

 

 

●● Other appliances being used on same

●● The unit requires a single outlet circuit, not

 

 

 

circuit.

 

shared with other appliances.

 

Unit trips circuit breaker or

●● An extension cord is being used.

●● Do NOT use an extension cord with this or

 

 

 

 

any other air conditioner.

 

blows fuses.

●● Circuit breaker or time-delay fuse isn't

●● Replace circuit breaker or time-delay fuse

 

 

 

 

 

of the proper rating.

 

for the proper rating. See "Electrical Rating

 

 

 

 

 

Tables” on page 13. If problem continues

 

 

 

 

 

contact a licensed electrician.

 

LCDI Power Cord Trips

●●

The LCDI Power cord can trip (Reset

●● Press and release RESET (listen for click;

 

(Reset Button Pops Out)

 

button POPS out) due to disturbances

 

Reset button latches and remains in) to

NOTE:

A damaged power supply cord must be

 

on your power supply line.

 

resume normal operation.

●●

Electrical overload, overheating or

●● Once the problem has been determined and

 

replaced with a new power supply cord

 

cord pinching can trip (Reset button

 

corrected, press and release RESET (listen

 

obtained from the product manufacturer

 

POPS out) the LCDI power cord.

 

for click; Reset button latches and remains in)

 

and must not be repaired.

 

 

 

to resume normal operation.

 

 

●● The return/discharge air grille is

●● Ensure that the return and/or discharge air

 

 

 

blocked.

 

paths are not blocked by curtains, blinds,

 

 

 

 

 

furniture, etc

 

 

●● Windows or doors to the outside are

●● Ensure that all windows and door are closed.

 

 

 

open.

 

 

 

 

●● The temperature is not set at a cool

●● Adjust the temperature control to a cooler or

 

 

 

enough/warm enough setting.

 

warmer setting as necessary.

 

 

●● The filter is dirty or obstructed.

●● Clean the filter, (See Recommended Mainte-

 

 

 

 

 

nance) or remove obstruction.

 

 

●● The indoor coil or outdoor coil is dirty

●● Clean the coils, (See Recommended Mainte-

 

 

 

or obstructed.

 

nance) or remove obstruction.

 

 

●● The temperature of the room you are

●● Allow additional time too cool a very hot room

Unit does not cool/heat room sufficiently, or cycles

 

trying to cool is extremely hot.

 

 

●●

The outside temperature is below

●● Do not try to operate your air conditioner in

 

on and off too frequently

 

 

 

60º F.

 

the cooling in the cooling mode when the

 

 

 

 

 

outside temperature is below 60º F. The unit

 

 

 

 

 

will not cool properly, and the unit may be

 

 

 

 

 

damaged.

 

 

●● The digital control is set to fan cycling

●● Since the fan does not circulate the room

 

 

 

mode.

 

air continuously at this setting, the room air

 

 

 

 

 

does not mix as well and hot (or cold) spots

 

 

 

 

 

may result. Using the continuous fan setting

 

 

 

 

 

is recommended to obtain optimum comfort

 

 

 

 

 

levels.

 

 

●● The air conditioner has insufficient

●● Check the cooling capacity of your unit to en-

 

 

 

cooling capacity to match the heat

 

sure it is properly sized for the room in which

 

 

 

gain of the room.

 

it is installed. Room air conditioners are not

 

 

 

 

 

designed to cool multiple rooms.

28

Image 28
Contents Ptac Table of Contents Congratulations Read Installation Operation ManualGeneral Instructions General Specifications Installation ChecklistPtac Installation Recommendations Typical Building Plan ViewWall Sleeve Installation Instructions Pdxws For Deep Wall Installation Greater than 13 1/4 SeeTypical Wall Sleeve Installation Falling Object HazardAlternate Wall Installations Panel WallFrame and Brick Veneer Curtain WallDimensions Wall Sleeve AttachmentOne-Piece Deep Wall Sleeve Installation Pdxwsext Lintel InstallationDrain Kit Location and Installation Internal DrainDrain Tube Installation See Figure Cover Plate InstallationDrain Kit Installation Pxga Standard Grille Installation Instructions Standard GrilleAll 230/208 volt units are equipped with power cords Power Cord Information 230/208V models onlyElectrical Rating Tables Power Cord Installation Electrical Wiring for 265 Volt ModelsElectrical Shock Hazard To Chassis Junction Chassis Install Preparation Suffocation HazardsShipping Tape Location Unit Damage HazardShipping Screw Location Excessive Weight Hazard Chassis InstallationSecuring Unit How To Connect Power ConnectionFriedrich Ptac Digital Control and Unit Features Page System Configuration Dip Switch Setting Digital Control User Input ConfigurationDip Switches Digital Control Operation Remote Control Thermostat Installation Desk Control Terminals Energy ManagementRoutine Maintenance Basic Troubleshooting Complaint Cause SolutionService & Assistance Accessories New Construction AccessoriesPxcja Friedrich Packaged Terminal AIR Conditioners and Heat Pumps This page Intentionally Left Blank This page Intentionally Left Blank This page Intentionally Left Blank

920-087-09 (12/10) specifications

The Friedrich 920-087-09 (12/10) is a remarkable air conditioning unit that exemplifies innovation in climate control technology. Designed for both residential and commercial environments, this model stands out for its efficiency, reliability, and user-friendly features.

One of the key characteristics of the Friedrich 920-087-09 is its impressive cooling capacity. With a nominal cooling power of 12,000 BTU, it is ideal for medium to large spaces, effortlessly maintaining comfortable indoor temperatures even during the hottest months. The unit offers a seasonal energy efficiency ratio (SEER) that meets contemporary standards, ensuring that it operates efficiently while consuming less energy. This feature not only lowers electricity bills but also reduces the overall environmental impact.

The Friedrich 920-087-09 is equipped with advanced inverter technology, allowing it to adjust its cooling power according to the temperature needs of the room. This results in quieter operation and enhanced energy savings as the unit avoids the frequent on-off cycles typical of conventional systems. Furthermore, the unit boasts a variable-speed compressor that guarantees consistent performance and improved humidity control.

Another standout feature of the Friedrich 920-087-09 is its sophisticated air filtration system. It includes a washable filter that captures dust, pollen, and other airborne particles, promoting cleaner air quality. This is particularly beneficial for those with allergies or respiratory issues, creating a healthier living environment.

The unit also features a customizable digital thermostat that allows users to set precise temperature preferences. With its user-friendly interface, users can easily switch between different modes, including cooling, heating, and dehumidifying, adding to the flexibility of the system. Additionally, Friedrich's exclusive Quiet Master technology minimizes noise levels, making it suitable for bedrooms, offices, and other quiet areas.

The Friedrich 920-087-09 also comes with a range of connectivity options, including Wi-Fi integration. This functionality allows users to control the air conditioning unit remotely through a smartphone app, making it exceptionally convenient for those with busy lifestyles.

Overall, the Friedrich 920-087-09 (12/10) combines cutting-edge technology, energy efficiency, and a host of user-friendly features, making it a top choice for anyone looking to enhance their indoor comfort. Its design is not only functional but also aesthetically pleasing, allowing it to blend seamlessly with a variety of interiors.