Zebra Technologies ZQ110 manual Function 080 GS k pL pH cn fn m d1...dk Fn=80 Format

Page 44

 

 

 

 

 

 

 

 

 

 

 

ZQ110

 

 

 

 

 

 

 

 

 

 

 

 

 

<Function 080> GS ( k pL pH cn fn m d1...dk

(fn=80)

 

 

 

 

 

 

[Format]

ASCII

GS

(

k

pL

 

pH

cn

fn

m

d1...dk

 

 

Hex

1D

28

6B

pL

 

pH

30

50

30

d1...dk

 

 

Decimal

29

40

107

pL

 

pH

48

80

48

d1...dk

 

[Range]

4 ≤ (pL + pH x 256) ≤ 65535 (0 ≤ pL ≤ 255, 0 ≤ pH ≤ 255)

 

 

 

 

cn=48

 

 

 

 

 

 

 

 

 

 

 

fn=80

m=48

0 ≤ d ≤ 255

k = (pL + pH x 256) - 3

[Description]

[Notes]

Stores the PDF417 symbol data (d1...dk) in the symbol save area.

Data stored in the symbol save area by this function are processed by Function 081. The data in the symbol save area are reserved after processing Function 081.

k bytes of d1...dk are processed as symbol data.

Specify only the data code word of the symbol with this function. Do not include the following data in the data d1..dk as this information is automatically added by the printer:

-Start pattern and stop pattern.

-Indicator code word of left and right.

-The descriptor of symbol length. (the first code word in the data area)

-The error correction code word calculated by modulus 929.

This function is effective until the following processing is performed:

-Function 080 or 180 is executed.

-ESC @ is executed.

-The printer is reset or the power is turned off.

<Function 081> GS ( k pL pH cn fn m

(fn=81)

 

 

 

 

 

 

[Format]

ASCII

GS

 

(

k

pL

pH

cn

fn

m

 

 

Hex

1D

 

28

6B

03

00

30

51

m

 

 

Decimal

29

 

40

107

3

0

48

81

m

 

[Range]

(pL + pH x 256) = 3 (pL=3, pH=0)

 

 

 

 

 

 

 

cn=48

 

 

 

 

 

 

 

 

 

 

fn=81

m=48

[Description]

[Notes]

Encodes and prints the PDF417 symbol data in the symbol save area.

In standard mode, use this function when printer is “at the beginning of a line,” or “there is no data in the printer buffer.”

A symbol with a size that exceeds the printing area can not be printed.

If there is any error described below in the data of the symbol save area, it cannot be printed.

-There is no data (Function 080 is not processed).

-If [(number of columns x number of rows) < number of code word] when auto processing is specified for number of columns and number of rows.

-Number of code word exceeds 928 in the data area.

Rev. 1.00

- 44 -

Mobile Printer Command Manual

Image 44
Contents ZQ110 ZQ110 ZQ110 Proprietary Statements Canadian Compliance Statement Copyrights EOT CanESC ESC GGS B GS HGS L GS TZQ110 Control Commands Details LSBControl Commands Details Ascii EOT=3 Error status Ascii Hex Decimal Description This command is ignored CR Ascii Can DLEAscii DLE ESC SP Ascii ESCName Select print modes Format ESC $ Name Select bit image mode Format Name Turn underline mode on/off Format Name Select default line spacing Format ESC = ESC @ESC D NULESC E Name Turn double-strike mode on/off Format ESC L When MSR set to Track 1/2 Read mode ESC M41H ~ 48H 65 ~ Byte Name Select an international character set Format ESC S Name Select print direction in page mode Format ESC W ESC \ ASC ESC ESC d Name Print and feed n lines Format ESC t Name Select character code table Format Name Turns upside-down printing mode on/off Format Name Select character size Format ZQ110 Output GS a Name Execute test print Format ZQ110 Function 112 GS F pL pH m aL aH bL bH =112 Format Datamatrix Function 065 GS k pL pH cn fn n Fn=65 Format Function 067 GS k pL pH cn fn n Fn=67 Format ZQ110 Function 080 GS k pL pH cn fn m d1...dk Fn=80 Format ZQ110 Output Function 165 GS k pL pH cn fn n1 n2 Fn=65 Format Function 169 GS k pL pH cn fn n Fn=69 Format Function 181 GS k pL pH cn fn m Fn=81 Format ZQ110 Function 367 GS k pL pH cn n Fn=67 Format Function 381 GS k pL pH cn fn m Fn=81 Format UPC-A UPC-EFunction 466 GS k pL pH cn fn n Fn=66 Format UCC/EAN-128&CC-C EAN-8UCC/EAN-128&CC-A/B ZQ110 Output Function 565 GS k pL pH cn fn n Fn=65 Format Function 567 GS k pL pH cn fn n Fn=67 Format Function 581 GS k pL pH cn fn m Fn=81 Format ZQ110 Function GS E pL pH fn d1 d2 fn=1 Format MSW MSW2 Khmer255 ZQ110 Function 4 GS E pL pH fn a Fn=4 Format GS L, GS 8 L Name Select graphics data Format Function 48 GS L pL pH m fn fn=0 Format Function 51 GS L pL pH m fn fn=3 Format NAK Dkb Hex ZQ110 Name Turns white/black reverse printing mode on / off Format ZQ110 Name Transmits printer ID Format GS I b Name Transmits battery status Format Name Set left margin Format GS T Name Set printing area width Format ZQ110 Name Execute macro Format Decimal GS f Name Select font for HRI characters Format GS h Name Selects bar code height Format NUL Ascii Range of k Range of dZQ110 CODE39, ITF, Codabar BS L a Name Change receipt mode Format BS M S PL PH fn2 m d1~dk Name Set Start characters Format Start 0DH 0AHUS US Name Get B/T configuration Format US US p Name Set B/T configuration Format 0x31 33H, 31H Reference for requesting Waln configuration 0PEAP Reference for setting Wlan configuration Success