Studer Innotec C3548 COMPACT, C1312 COMPACT user manual Maintenance, Diagram of the different mode

Page 22

STUDER INNOTEC

COMPACT

5.5.1Diagram of the different mode

 

 

 

 

 

 

 

 

 

Show an off LED

 

 

 

 

 

 

 

 

 

Show a blinking LED

 

 

 

 

 

 

 

 

 

Show a lighted LED

 

 

 

 

 

 

 

 

 

 

AC IN

 

1

 

8

 

 

 

AC OUT

All the functions are enabled. This is the

 

 

 

 

 

 

7

 

 

 

 

 

factory setting.

CHARGER

 

2

9

 

 

 

INVERTER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AC IN

 

1

 

8

 

 

 

AC OUT

The inverter is disabled. Only the transfer

CHARGER

 

2

7

9

 

 

 

INVERTER

switch and the charger will work normally.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AC IN

 

1

 

8

 

 

 

AC OUT

Charger and transfer switch are disabled. the

 

 

 

 

 

 

 

 

7

 

 

 

 

 

inverter will work continuously even if there is

CHARGER

 

2

9

 

 

 

INVERTER

a correct AC voltage at the input

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AC IN

 

1

 

8

 

 

 

AC OUT

Inverter and charger are both disabled.

 

7

 

 

 

Only the transfer switch function is enabled in

 

 

 

 

 

 

 

 

CHARGER

 

2

9

 

 

 

INVERTER

input voltage and frequency is OK.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6 Maintenance

Apart from the periodic controls mentioned for the connections, the COMPACT does not need any maintenance. Keep the appliance clean and from time to time wipe it clean with a damp cloth.

7 EC Compliance

We hereby state that the products described in this user manual meets the following standards:

EN50081 I/II, EN55014 – EN61000-2-3, IEC801 II/III/IV, LVD 73/23/EEC, EMC Dir. 89/336

CH-1950 Sion, 31st of March 2000

STUDER INNOTEC (R. Studer)

User manual

COMPACT V2.0 E

22

Image 22
Contents User and installer Manual Compact V2.0 EIndex table Reset Value Battery Voltages and Absorption Time General Information Special Precautions Introduction Principe schematicDescription of main functions Solar charge regulator optional Battery connectionsRemote control Parallel ConnectionFixing AssemblyPlace of assembly ConnectionProtection cover for the terminals connections Connecting Plan / Front sideSolar + Cabling/wiring Connect the Solarmodules Solar +/- Only for solar option Connection to Remote controlConnection to Temperature Sensor Temp Connection to Auxiliary ContactOperating Display and operating control elementsPush buttons Light Emitting DiodesTurning Knobs Charge detection system „Standby Battery ConditionInverter OverloadCycle of charge Battery chargerInput current repartition Power sharing Equalization chargingTransfer system Charging currentSolar charge regulator option Fast UPS- Mode for the Transfer SwitchDelayed mode of the Transfer System Multifunctional ContactRemote Control Maximum Contact load -230Vac /16Amp-30Vdc/1AReset value Temperature sensorStandard setting Battery voltages and absorption timeThese four red LED show the function Set Program the auxiliary contactSet the voltage and timing threshold LED11Example Manual operating of Auxiliary ContactMaintenance Diagram of the different modeSolar Charge Regulator-Floating Technical DataType Various data