8 Technical Data

Type

C1312

 

C2324

 

C3548

Inverter

 

 

 

 

 

 

Nominal battery voltage

12V

 

 

24V

 

48V

Input voltage range

9.5 – 16V

 

 

19 – 32V

 

38 – 64V

Nominal power (W)

1300VA

 

 

2300VA

 

3500VA

Maximum power 30 min

1600VA

 

 

2500VA

 

4000VA

Maximum power 3min.

2000VA

 

 

3000VA

 

4800VA

Maximum power 5 sec

3500VA

 

 

6000VA

 

9000VA

Maximum load

 

 

Up to short circuit

 

 

Asymmetrical load max.

 

 

Up to Pnom

 

Standby adjustable

 

 

 

1 – 25W

 

Cos ϕ

 

 

 

0.1 – 1

 

Maximum efficiency

94%

 

 

95%

 

95%

Power OFF, Standby, ON

0.5W-0.6W

 

0.8W-09W

 

1.2W-1.4W

Power normal working no load

6W

 

 

9W

 

12W

Output voltage

 

 

230Vac ± 10%

 

 

Output frequency quartz controlled

 

 

50 Hz± 0.05 %

 

Maximum distortion

 

 

 

< 2%

 

 

Dynamic behaviour 0 100 %

 

 

 

0.5ms

 

Overload and short circuit protection

Automatic disconnection with 5 time restart attempt

Overheating temperature protection

Acoustic warning before shut-off. Automatic restart

Battery Charger

 

 

 

 

 

 

Charging current adjustable

0-55A

 

 

0-55A

 

0-50A

Setting of AC INPUT current POWER SHARING

 

 

 

0 to 15A

 

 

Maximum input voltage

 

265 Vac , 350 V peak

 

Minimum input voltage

 

Adjustable 150 – 230Vac

 

Frequency range

 

 

44 – 65Hz

 

Power factor correction (PFC) EN 61000-3-2

 

 

EN 61000-3-2

 

Solar Charge Regulator-Floating

 

 

 

 

 

 

Maximum no load voltage

25V

 

 

45V

 

90V

Maximum charging current

30A

 

 

30A

 

20A

Function principle

Shunt regulator

I / U / Uo

/ equalize

Battery Monitoring (25°C) in accordance with TLBM(True Level Battery Management)

*Absorption charge time

 

0 – 4h

 

*End of charge cycle voltage

14.4V

28.8V

57.6V

*Floating voltage

13.6V

27.2V

54.4V

*Equalization voltage every 25 cycles

15.3V

31.6V

63.2V

*Low battery disconnection voltage

10.8V

21.6V

43.2V

Temperature compensation (Option)

 

3mV / °C / cell

 

Various data

Potential free Multifunction contact

16A - 250Vac / 3A – 60 dc

Weight

16.0kg

17.1kg

29.4kg

Dimension H * W * L (mm)

124 / 215 / 480

124 / 215 / 480

124 / 215 / 670

Protection index IP

 

IP22

 

EEC – Compliance

EN50081 I/II, EN 55014 – EN 55022, EN 61000-3-2

 

IEC 801 I/II/III/IV, CEI 555, IEC 1000-3-2, LVD 73/23/EEC

Operating temperature

 

-20 to 55°C

 

Ventilation

 

from 45°C

 

Commutation time (UPS-Mode)

 

20 ms

 

Noise level without/with ventilation (dB)

 

< 10 / < 35 / 50dB

 

Options

Remote control (111.5 x 136.5 x 25mm / 20m Cable)

RCC-01

Temperature sensor (58 x 51.5x 22mm / 3m Cable)

CT-35

Protection cover for terminals

CFC - 01

IP 23 Protection cover for COMPACT

CIP - 23

We reserve the right to make any changes without issuing any prior notice *These value can be modified according to the table chapter 5.3.1

User manual

COMPACT V2.0 E

23

Image 23
Contents Compact V2.0 E User and installer ManualIndex table Reset Value Battery Voltages and Absorption Time General Information Special Precautions Description of main functions Principe schematicIntroduction Parallel Connection Battery connectionsRemote control Solar charge regulator optionalConnection AssemblyPlace of assembly FixingSolar + Connecting Plan / Front sideProtection cover for the terminals connections Cabling/wiring Connection to Auxiliary Contact Connection to Remote controlConnection to Temperature Sensor Temp Connect the Solarmodules Solar +/- Only for solar optionDisplay and operating control elements OperatingTurning Knobs Light Emitting DiodesPush buttons Overload Battery ConditionInverter Charge detection system „StandbyEqualization charging Battery chargerInput current repartition Power sharing Cycle of chargeCharging current Transfer systemMultifunctional Contact Fast UPS- Mode for the Transfer SwitchDelayed mode of the Transfer System Solar charge regulator optionMaximum Contact load -230Vac /16Amp-30Vdc/1A Remote ControlBattery voltages and absorption time Temperature sensorStandard setting Reset valueLED11 Program the auxiliary contactSet the voltage and timing threshold These four red LED show the function SetManual operating of Auxiliary Contact ExampleDiagram of the different mode MaintenanceVarious data Technical DataType Solar Charge Regulator-Floating